R20UT3754EJ0101-AUTOSARs




 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
RUCG Tool 
User’s Manual 
 
 
 
 
 
 
 
Version 1.1.3 
 
 
 
 
 
Target Device: 
RH850/P1M 
 
 
 
 
 
 
 
 
 
 
 
All information contained in these materials, including products and product specifications, 
represents information on the product at the time of publication and is subject to change by 
Renesas Electronics Corp. without notice. Please review the latest information published by 
Renesas Electronics Corp. through various means, including the Renesas Electronics Corp. 
website (http://www.renesas.com). 
 
 
 
 
 
 
 
 
www.renesas.com 
Rev.1.01 Feb 2017 
 
 

 
 

 

 
 
 
 
 
Notice 
1. 
Descriptions of circuits, software and other related information in this document are provided only to illustrate the operation of 
semiconductor products and application examples. You are fully responsible for the incorporation or any other use of the circuits, 
software, and information in the design of your product or system. Renesas Electronics disclaims any and all liability for any losses 
and damages incurred by you or third parties arising from the use of these circuits, software, or information. 
2. 
Renesas Electronics hereby expressly disclaims any warranties against and liability for infringement or any other disputes involving patents, 
copyrights, or other intellectual property rights of third parties, by or arising from the use of Renesas Electronics products or technical 
information described in this document, including but not limited to, the product data, drawing, chart, program, algorithm, application 
examples. 
3. 
No license, express, implied or otherwise, is granted hereby under any patents, copyrights or other intellectual property rights of Renesas 
Electronics or others. 
4. 
You shall not alter, modify, copy, or otherwise misappropriate any Renesas Electronics product, whether in whole or in part. Renesas 
Electronics disclaims any and all liability for any losses or damages incurred by you or third parties arising from such alteration, 
modification, copy or otherwise misappropriation of Renesas Electronics products. 
5. 
Renesas Electronics products are classified according to the following two quality grades: "Standard" and "High Quality". The intended 
applications for each Renesas Electronics product depends on the product’s quality grade, as indicated below.  
"Standard":          Computers; office equipment; communications equipment; test and measurement equipment; audio and visual equipment; 
home electronic appliances; machine tools; personal electronic equipment; and industrial robots etc. 
"High Quality":   Transportation equipment (automobiles, trains, ships, etc.); traffic control (traffic lights); large-scale communication 
equipment; key financial terminal systems; safety control equipment; etc. 
Renesas Electronics products are neither intended nor authorized for use in products or systems that may pose a direct threat to human life or 
bodily injury (artificial life support devices or systems, surgical implantations etc.), or may cause serious property damages (space and 
undersea repeaters; nuclear power control systems; aircraft control systems; key plant systems; military equipment; etc.). Renesas Electronics 
disclaims any and all liability for any damages or losses incurred by you or third parties arising from the use of any Renesas Electronics 
product for which the product is not intended by Renesas Electronics. 
6. 
When using the Renesas Electronics products, refer to the latest product information (data sheets, user’s manuals, application notes, "General 
Notes for Handling and Using Semiconductor Devices" in the reliability handbook, etc.), and ensure that usage conditions are within the 
ranges specified by Renesas Electronics with respect to maximum ratings, operating power supply voltage range, heat radiation 
characteristics, installation, etc. Renesas Electronics disclaims any and all liability for any malfunctions or failure or accident arising out of 
the use of Renesas Electronics products beyond such specified ranges. 
7. 
Although Renesas Electronics endeavors to improve the quality and reliability of Renesas Electronics products, semiconductor products have 
specific characteristics such as the occurrence of failure at a certain rate and malfunctions under certain use conditions. Further, Renesas 
Electronics products are not subject to radiation resistance design. Please ensure to implement safety measures to guard them against the 
possibility of bodily injury, injury or damage caused by fire, and social damage in the event of failure or malfunction of Renesas Electronics 
products, such as safety design for hardware and software including but not limited to redundancy, fire control and malfunction prevention, 
appropriate treatment for aging degradation or any other appropriate measures by your own responsibility as warranty for your 
products/system. Because the evaluation of microcomputer software alone is very difficult and not practical, please evaluate the safety of the 
final products or systems manufactured by you. 
8. 
Please contact a Renesas Electronics sales office for details as to environmental matters such as the environmental compatibility of each 
Renesas Electronics product. Please investigate applicable laws and regulations that regulate the inclusion or use of controlled substances, 
including without limitation, the EU RoHS Directive carefully and sufficiently and use Renesas Electronics products in compliance with all 
these applicable laws and regulations. Renesas Electronics disclaims any and all liability for damages or losses occurring as a result of your 
noncompliance with applicable laws and regulations. 
9. 
Renesas Electronics products and technologies shall not be used for or incorporated into any products or systems whose manufacture, use, or 
sale is prohibited under any applicable domestic or foreign laws or regulations. You shall not use Renesas Electronics products or 
technologies for (1) any purpose relating to the development, design, manufacture, use, stockpiling, etc., of weapons of mass destruction, 
such as nuclear weapons, chemical weapons, or biological weapons, or missiles (including unmanned aerial vehicles (UAVs)) for delivering 
such weapons, (2) any purpose relating to the development, design, manufacture, or use of conventional weapons, or (3) any other purpose of 
disturbing international peace and security, and you shall not sell, export, lease, transfer, or release Renesas Electronics products or 
technologies to any third party whether directly or indirectly with knowledge or reason to know that the third party or any other party will 
engage in the activities described above. When exporting, selling, transferring, etc., Renesas Electronics products or technologies, you shall 
comply with any applicable export control laws and regulations promulgated and administered by the governments of the countries asserting 
jurisdiction over the parties or transactions. 
10.  Please acknowledge and agree that you shall bear all the losses and damages which are incurred from the misuse or violation of the terms and 
conditions described in this document, including this notice, and hold Renesas Electronics harmless, if such misuse or violation results from 
your resale or making Renesas Electronics products available any third party. 
11.  This document shall not be reprinted, reproduced or duplicated in any form, in whole or in part, without prior written consent of Renesas 
Electronics. 
12.  Please contact a Renesas Electronics sales office if you have any questions regarding the information contained in this document or Renesas 
Electronics products. 
 
(Note 1)   "Renesas Electronics" as used in this document means Renesas Electronics Corporation and also includes its majority-owned 
subsidiaries. 
(Note 2)   "Renesas Electronics product(s)" means any product developed or manufactured by or for Renesas Electronics

 

 

 
 
 

 
 
 
Abbreviations and Acronyms 
 
 
 
Abbreviation / Acronym 
Description 
ARXML/arxml 
AUTOSAR xml 
AUTOSAR 
AUTomotive Open System Architecture 
BSWMDT 
Basic Software Module Description Template 
<MSN> 
Module Short Name 
ECU 
Electronic Control Unit 
DMA 
Direct Memory Access 
ECU 
Electronic Control Unit 
MCAL 
Microcontroller Abstraction Layer 
MCU 
Microcontroller Unit 
XML 
eXtensible Mark-up Language 
DLL 
Dynamic Linking Library 
 
 
 
Definitions 
 
 
 
Terminology 
Description 
.arxml 
AUTOSAR XML File. 
.trxml 
Translation XML File. 
PerlCtrl 
The utility converts a Perl program into an ActiveX control. 

 

 

 

 
Table of Contents 
 
Chapter 1 Introduction .........................................................................9 
1.1 
Document Overview ............................................................................................................... 9 
Chapter 2 Reference ........................................................................... 11 
2.1. 
Reference Documents.......................................................................................................... 11 
2.2. 
Trademark Notice ................................................................................................................ 11 
Chapter 3 Tool Overview ..................................................................... 13 
3.1 
Usage..................................................................................................................................... 13 
Chapter 4 Input Files .......................................................................... 17 
4.1 
Msn Control DLL .................................................................................................................. 17 
4.2 
ECU Configuration Description File(s) .............................................................................. 17 
4.3 
BSWMDT File ........................................................................................................................ 17 
4.4 
Translation XML File ............................................................................................................ 18 
4.4.1 

Translation Header File ............................................................................................. 18 
4.4.2 
Device Specific Header File ...................................................................................... 18 
4.5 
Configuration XML File ........................................................................................................ 19 
4.6 
Other Description Files........................................................................................................ 19 
Chapter 5 Output Files ....................................................................... 21 
Chapter 6 Precautions ........................................................................ 23 
Chapter 7 User Configuration Validation .......................................... 25 
Chapter 8 Messages ........................................................................... 27 
8.1. 
RUCG Tool Messages .......................................................................................................... 27 
8.1.1 

Error Messages ......................................................................................................... 27 
8.1.2 
Warning Messages ................................................................................................... 28 
8.1.3 
Information Messages ............................................................................................... 28 
8.2. 
Common Messages ............................................................................................................. 28 
8.2.1 

Error Messages ......................................................................................................... 28 
8.2.2 
Warning Messages ................................................................................................... 31 
8.2.3 
Information Messages ............................................................................................... 31 
8.3. 
R3.2.2 Messages .................................................................................................................. 31 
8.3.1 
Error Messages ......................................................................................................... 32 
8.3.2 
Warning Messages ................................................................................................... 32 
8.3.3 
Information Messages ............................................................................................... 32 
8.4. 
R4.0.3 Messages .................................................................................................................. 32 
8.4.1 

Error Messages ......................................................................................................... 32 
8.4.2 
Warning Messages ................................................................................................... 33 
8.4.3 
Information Messages ............................................................................................... 33 
Chapter 9 Notes .................................................................................. 35 
Chapter 10 Appendix .......................................................................... 37 

 

 
List of Figures 
 
Figure 3.1 Tool Overview ........................................................................................................................ 13 
 
 
 
 
 
List of Tables 
 

Table 1.1 Document Overview .................................................................................................................. 9 
Table 2.1 Reference Documents .............................................................................................................. 11 
Table 3.1 Options and Description ........................................................................................................ 14 
Table 8.1 R3.2.2 BSWMDT Mandatory Parameters .............................................................................. 32 
Table 8.2 R4.0.3 BSWMDT Mandatory Parameters .............................................................................. 33 
 
 

 

Introduction                                                                                                                                    Chapter 1 
Chapter 1  
Introduction 
 
 
 
 
The document describes the features of the RUCG Tool.  
 
RUCG Tool is a command line tool that extracts information from ECU 
Configuration Description File(s) and generates Driver C source and C header 
files. 
 
This document contains information on the options, input and output files of the 
RUCG Tool. In addition, this manual covers a step-by-step procedure for the 
usage of tool. 
 
 
 
 
 
1.1 
Document Overview 
 
 
This user manual is organized as given in the table below: 
 
 
 
Table 1.1 Document Overview 
Section 
Contents 
Section 1 (Introduction) 
Provides an introduction to the document and explains how 
information is organized in this manual. 
Section 2 (Reference) 
Provides a list of documents referred while developing this 
document. 
Section 3 (RUCG Tool 
Provides the component overview of RUCG. 
Overview) 
Section 4 (Input Files) 
Provides information about all the input files supplied to 
Tool. 
Section 5 (Output Files) 
Explains the output files that are generated by the RUCG Tool. 
Section 6 (Precautions) 
Contains precautions to be taken during execution of 
RUCG Tool. 
Section 7 (User Configuration  Describes about user configuration validation done by the RUCG 
Validation) 
Tool. 
Section 8 (Messages) 
Describes all the Error/Warning/Information messages that 
help the user to understand the probable reason for the 
same. 
Section 9 (Notes) 
Provides notes to help the user to understand this document 
better. 
Section 10(Appendix) 
Provides additional information, if any. 

 

Chapter 1                                                                                                                                    Introduction 
 
 
10 
 

Reference                                                                                                                              Chapter 2 
Chapter 2  
Reference 
 
 
 
 
2.1. 
Reference Documents 
 
 
The following table lists the documents referred to develop this document: 
 
 
 
Table 2.1 Reference Documents 
Sl.No.  Title 
Version 
1. 
EAAR-RS-0089.pdf 
1.1.0 
2. 
GettingStarted_MCAL_Drivers_X1x.pdf 
1.0.6 
 
 
 
 
 
2.2. 
Trademark Notice 
 
 
Microsoft and Windows are trademarks/registered trademarks of Microsoft 
Corporation. 
11 
 

Chapter 2                                                                                                                              Reference 
 
 
12 
 


Tool Overview                                                                                                                       Chapter 3 
Chapter 3   Tool Overview 
 
 
 
RUCG Tool is a command line tool that provides scalability and 
configurability for the component. It accepts Module Specific DLL, ECU 
Configuration Description File(s), BSWMDT File, Translation XML File and 
Configuration XML File as input and generates the C Header and C 
Source files. However Configuration XML File is optional. 
 
RUCG Tool is a standalone windows executable. The Tool can run without 
any additional dependencies. 
 
Operating Environment:  
Operating System 
Windows 7 Professional SP1 64 bit 
RAM 
8 GB 
 
RUCG Tool doesn’t support parallel execution. 
 
Figure 3.1 Tool Overview 
For more information about input files to be given to the RUCG tool 
refer section “4 Input Files”. 
 
For more information about output files generated by the RUCG tool 
refer section “5 Output Files”. 
 
3.1  Usage 
 
This section provides the information regarding usage of the RUCG 
Tool. It also provides the syntax of the command line arguments 
(input filenames and options). 
RUCG Tool executable is invoked as shown below. 
 
RUCG.exe <DLL Path> [<Options>] {<Input Filename>} 
 

13 
 

Chapter 3                                                                                                                       Tool Overview 
 
Where, 
 
RUCG.exe: RUCG Tool Executable 
DLL Path: Module specific DLL file path 
Options: [-H/-Help -C/-Config -O/-Output -Osrc -Oinc -L/-Log –F/-
FILVERSION -D/-Dryrun –T/-TimeOut] 
Input Filename: {ECU Configuration Description File(s), BSWMDT 
File, Translation XML File [optional] and Configuration XML File 
[optional]} 
 
Notations: 
{data} represents compulsory data 
<data> represents the actual data that will be specified on command 
line during tool usage. 
[data] represents optional data. 
 
 
 
Table 3.1 Options and Description 
Options 
Description 
-H/-Help 
To display help regarding usage of the tool. Gets the highest priority when 
used with other options. 
-C/-Config 
To execute tool with the options provided in the Configuration XML File. 
Command line options get the higher priority than the options provided in 
Configuration XML File. 
-O/-Output 
By default, the tool generates output files in the  
“<Msn>_Output” folder in the path where DLL is present. The user can use 
the -O option followed by the folder name, to generate the output files in the 
specified folder. Either absolute path or relative path can be provided to 
specify the folder name.  
The C Source and C Header files are generated in the sub folders “src‟ and 
“inc‟ within the output folder. 
-Osrc 
The user can use the -Osrc option followed by the folder name, to generate 
the C Source files in the specified folder. 
-Oinc 
The user can use the -Oinc option followed by the folder name, to generate 
the C Header files in the specified folder. 
–L/-Log 
To log the output to the <Msn>.log file in the output folder. 
-D/-Dryrun 
To execute tool in validation mode. The tool will not generate output files even 
though the input file provided is error free. 
-F/-FILEVERSION  To display the perl file version which are used to create the DLL. 
-T/-TimeOut 
The user can use the –TimeOut option followed by the timeout value, to set 
the maximum timeout for underlying DLL execution. Default timeout value is 
10 seconds. Timeout value should be in the range of 1 – 60 seconds. 
 
Remark   
  If the “-H/-Help” option is provided on the command line without any 
other inputs, RUCG Tool help is displayed. 
14 
 

Tool Overview                                                                                                                       Chapter 3 
  If the “-H/-Help” option is provided with DLL path, module specific 
DLL help is displayed. 
  If Translation XML File is not provided on the command line then 
"<Msn>_X1x.trxml" which is present in the same location of DLL is 
considered as "default" Translation XML File by the RUCG Tool. 
  If Configuration XML File is not provided on the command line then 
"<Msn>_X1x.cfgxml" which is present in the same location of DLL is 
considered as "default" Configuration XML File by the RUCG Tool. 
  The RUCG tool doesn’t allow parallel execution. 
  The RUCG tool returns its execution status to the user through the 
console. User can get this tool return status using the environment 
variable %ERRORLEVEL%.
15 
 

Chapter 3                                                                                                                       Tool Overview 
 
 
 
16 
 

Input Files                                                                                                                             Chapter 4 
Chapter 4   Input Files 
 
 
RUCG Tool accepts the following files as inputs to generate output files. 
 
 
4.1  Msn Control DLL 
 
Module specific DLL File can be generated using PerlCtrl utility from the 
perl scripts. The Perl script contains implementation of generating 
configuration output files with PerlCtrl template. PerlCtrl accepts the perl 
scripts and generates module specific DLL. For the PerlCtrl template 
contents, refer Chapter "10 Appendix". 
 
4.2  ECU Configuration Description File(s) 
 
The ECU Configuration Description file is in XML format, which contains 
the configured values for Parameters, Containers and Modules. ECU 
Configuration Description XML File format will be compliant with the 
AUTOSAR ECU specification standards. ECU Configuration Description 
File can be created or edited using ECU Configuration Editor. 
  
4.3  BSWMDT File  
 
The BSWMDT File in XML format, which is the template for the Basic 
Software Module Description. BSWMDT File format will be compliant with 
the AUTOSAR BSWMDT specification standards. 
 
RUCG Tool uses "Common Published Information" from module specific 
BSWMDT file. BSWMDT file should not be updated manually since it is 
"Static Configuration" file. 
 
The required elements from BSWMDT File by module specific Generation 
Tool is as follows: 
 
BSW-MODULE-DESCRIPTION 
• MODULE-ID 
 
BSW-IMPLEMENTATION 
• SW-VERSION 
• VENDOR-ID 
• AR-RELEASE-VERSION 
• VENDOR-API-INFIX 
 
In case of multiple driver support implementation, VENDOR-API-INFIX is 
mandatory. In case of single driver support implementation, VENDOR-
API- INFIX is not used. 
17 
 

Chapter 4                                                                                                                             Input Files 
 
 
 
4.4  Translation XML File 
 
Translation XML File is in XML format which contains translation and 
device specific header file path. For the syntax of the contents of 
Translation XML File, please refer the Chapter 10 Appendix. 
If mapped device specific address label is changed/updated then only 
respective mapping in Translation Header File needs to be updated. In 
this case there will not be any impact on Generation Tool for the 
generation of address in tool generated output file(s). 
 
4.4.1  Translation Header File 
 
This file is look-up table (mapping in the form of definitions) for the device 
specific address labels. Based on the configuration in ECU Configuration 
Description File, the mapped device specific address labels will be 
searched in Device Specific Header File by RUCG Tool to generate 
associated address in tool generated output file(s). For the Translation 
Header File path, the value of "<Msn>DeviceName" parameter from the 
container "<Msn>General" container should be present as child tag of 
TRANSLATION-FILE-PATH in Translation XML File. Both "Absolute" and 
"Relative" paths are supported by generation tool however default path is 
"Relative" path. 
 
E.g. 
<TRANSLATION-FILE-PATH> 
<Value_Of_MsnDeviceName>..\DF_Timer.h ..\DF_Timer_ISR.h</ 
Value_Of_MsnDeviceName> 
</TRANSLATION-FILE-PATH> 
 
4.4.2  Device Specific Header File  
 
This file contains device specific labels and associated address. Based on 
the configuration in ECU Configuration Description File, the mapped 
device specific address labels will be used to generate associated 
address in tool generated output file(s). For the Device Specific Header 
File path, the value of “<Msn>DeviceName” parameter from the container 
“<Msn>General” container should be present as child tag of DEVICE-
FILE-PATH in Translation XML File. Both “Absolute” and “Relative” paths 
are supported by generation tool however default path is “Relative” path.  
 
If multiple Device Specific Header Files need to be provided for the same 
device (value of “<Msn>DeviceName” parameter) in Translation XML File, 
then each Device Specific Header File path should be separated with 
“space”.  
18 
 

Input Files                                                                                                                             Chapter 4 
 
 
E.g.  
<DEVICE-FILE-PATH>  
<Value_Of_MsnDeviceName>..\DF_Timer.h ..\DF_Timer_ISR.h</ 
Value_Of_MsnDeviceName>  
</DEVICE-FILE-PATH>  
4.5  Configuration XML File  
 
Configuration XML File is in XML format which contains command line 
options and input/output path. For the syntax of the contents of 
Configuration XML File, please refer the Chapter 10 Appendix. 
E.g. 
<LOG>ON/OFF</LOG> 
<HELP>ON/OFF</HELP> 
 
4.6  Other Description Files 
 
RUCG Tool requires other description files (i.e. Dem File and MCU File) 
inputs, depends on the corresponding parameter configuration in the ECU 
Configuration Description File 
19 
 

Chapter 4                                                                                                                             Input Files 
 
 
 
20 
 

Output Files                                                                                                                          Chapter 5 
Chapter 5  
Output Files 
 
 
RUCG Tool is a command line tool that provides scalability and 
configurability for Msn Driver component. It accepts inputs which 
mentioned in the Chapter 4 Input Files and generates configuration details 
in C Header and C Source files (<Msn>_Cfg.h, <Msn>_Cbk.h, 
<Msn>_Lcfg.c and <Msn>_PBcfg.c). 
 
<Msn>_Cfg.h 
This file contains pre-compile configuration parameters. 
 
<Msn>_Cbk.h 
This file contains prototype declarations for callback notification functions. 
 
<Msn>_Lcfg.c 
This file contains link-time parameters. 
 
<Msn>_PBcfg.c 
This file contains post-build configuration data. 
 
Log File 
The file which briefs the execution details of RUCG Tool. 
 
 
Remark: Output files generated by Msn Driver Generation Tool should not be modified or 
edited manually 
21 
 

Chapter 5                                                                                                                          Output Files 
 
 
 
22 
 

Precautions                                                                                                                           Chapter 6 
Chapter 6  
Precautions 
 
 
 
 
• 
Module Specific DLL must be created by using PerlCtrl with the 
PerlCtrl template which specified in this document. For the PerlCtrl 
template contents, refer Chapter "10 Appendix". 
 
• 
ECU Configuration Description File and BSWMDT File must comply 
with AUTOSAR standard for R4.0 ECU Configuration Description File 
and BSWMDT File respectively. 
 
• 
Default Translation XML File (<Msn>_Xx4.trxml) must be present in 
same location of DLL file. 
 
• 
Default Configuration XML File (<Msn>_Xx4.cfgxml) must be present in 
same location of DLL file. 
 
• 
If  Translation  XML  File  is  not  provided  on  the  command  line, 
<msn>_Xx4.trxml  which  is  present  in  same  location  of  DLL  file  is 
considered as ‘default’ Translation XML File. 
 
• 
If Configuration XML File is not provided on the command line, 
Msn_Xx4.cfgxml which is present in same location of DLL file is 
considered as ‘default’ Configuration XML File. 
 
• 
ECU Configuration Description File(s) should contain the file 
extension ‘.arxml’. 
 
• 
Translation XML File should contain the file extension ‘.trxml’. 
 
• 
Configuration XML File should contain the file extension ‘.cfgxml’. 
 
• 
If the output files generated by RUCG Tool are modified externally, 
then they may lead to error while compilation or not produce the 
expected results. 
 
 
 
23 
 

Chapter 6                                                                                                                            Precautions 
 
 
 
24 
 

User Configuration Validation                                                                                             Chapter 7 
Chapter 7  
User Configuration Validation 
 
 
 
 
This section provides help to analyze the error, warning and information 
messages displayed during the execution of RUCG Tool. It ensures 
conformance of input file with syntax and semantics. It also performs 
validation on the input file for correctness of the data. 
 
 
For more details on list of Error/Warning/Information messages that are 
displayed as a result of input file(s) validation, refer Chapter “8 
Messages”. 
 
 
The RUCG Tool displays error or warning or information messages when 
the user has configured incorrect inputs. There are two types of messages 
displayed, 
 
RUCG Tool generated messages 
Module Specific DLL generated messages 
 
The format of RUCG Tool generated message is as shown below. 
 
• 
CGERR/CGINF/CGWAR<xx><yy>: 
<Error/Warning/Information Message>. 
<xx>: Stage of error happen 
<yy>: Actual error code 
 
The format of Module Specific DLL generated messages is as shown 
below. 
 
• 
ERR/WRN/INF<mid><xxx>: <Error/Warning/Information 
Message>. where, 
<mid>: 123 - MSN Driver Module id (123) for user configuration checks. 
 
000 - for command line checks. 
 
<xxx>: 001-999 - Message id. 
 
• 
File Name: Name of the file in which the error has occurred 
 
• 
Path: Absolute path of the container in which the parameter is present. 
 
‘File Name’ and ‘Path’ need not be present for all 
Error/Warning/Information messages. 
25 
 

Chapter 7                                                                                             User Configuration Validation 
 
 
26 
 

Messages                                                                                                                              Chapter 8 
Chapter 8  
Messages 
 
 
The messages help to identify the syntax or semantic errors in the inputs 
supplied to execution.  
The following section gives the list of error, warning and information 
messages displayed during the tool execution. 
When the tool detects the following errors, it will automatically exit after 
showing the error message. 
 
8.1. 
RUCG Tool Messages 
 
This section contains the list of error/warning/information messages which 
is generated by the RUCG tool. 
8.1.1  Error Messages 
 
CG_ERR0001: Another instance is already running. 
This error occurs, if trying to run more than one instance of application in 
parallel. 
 
CG_ERR0002: First argument should be a module specific DLL file 
path. 
This error occurs, if the specified first file argument does not have 
extension (.dll or .ocx). 
 
CG_ERR0003: DLL not found on specified path. 
This error occurs, if the specified DLL file input is not found in the 
specified location. 
 
CG_ERR0004: Specified module specific DLL file is not DLL 
executable. 
This error occurs, if the specified DLL file is not a windows executable 
DLL. 
 
CG_ERR0101: Please provide valid number of arguments. 
This error will occur, if the no option is provided in the command line.  
 
CG_ERR0102: Please provide valid time out value in seconds (1 - 60). 
This error occurs, if the specified timeout value is invalid or out of range. 
 
CG_ERR0301: DLL activation context creation failed. 
This error occurs, if the generated manifest file for the specified DLL is 
wrong. Ensure the manifest file write implementation in the RUCG Tool. 
 
CG_ERR0302: Specified DLL implemented using wrong PerlCtrl 
template. 
This error occurs, if the specified DLL file is created using wrong Control ID 
in PerlCtrl template. For the PerlCtrl template contents, refer Chapter "10 
Appendix". 
 
CG_ERR0303: DLL directory should be write-enabled. 
This error occurs, if the specified DLL file path is write protected. 
 
CG_ERR0401: Code generation is not completed within the time out. 
This error occurs, if the specified DLL does not return within a default or 
specified timeout. 
 
27 
 

Chapter 8                                                                                                                              Messages 
Note: When Code Generation is terminated due to timeout, the RUCG Tool 
drops a temporary file (GLOB(0x2a8d104)) in the execution location. Please 
delete the file after the execution. 
 
CG_ERR0402: Cannot find implementation of method "execution” in 
the DLL. 
This error will occur, if the specified DLL created without entry function call 
"execute". 
 
CG_ERR0403: Error occurred while code generation. 
This error will occur, when the specified DLL calls “exit” function while its 
execution. In the tool code implementation, general assumption is “exit” 
function in the perl script should called only at the erroneous conditions.  
  
8.1.2  Warning Messages 
 
None 
 
8.1.3  Information Messages 
 
CG_INF0001: Tool Version 
 
This is to display Tool Version for each execution of the tool. 
 
CG_INF0002: Module DLL Path 
This is to display parsed Module DLL Path from the command line 
arguments. 
 
CG_INF0003: <RUCG Tool Usage Information> 
This is to display usage information of the tool. 
 
CG_INF0004: Execution terminated due to parallel execution errors. 
This information will occur, if the execution is terminated due to parallel 
execution. 
 
CG_INF0005: Execution terminated due to command line errors. 
This information will occur, if the execution is terminated due to command 
line errors. 
 
CG_INF0006: Execution terminated due to the previous errors. 
This information will occur, if the error happened during the DLL execution. 
 
CG_INF0007: Code generation completed successfully. 
This information will occur, if the tool execution completed successfully. 
 
8.2. 
Common Messages 
 
This section contains the list of error/warning/information messages which 
is common for AUTOSAR Renesas R3.2.2 and R4.0.3 X1x MCAL Driver 
module that will be generated during the Module Specific DLL execution. 
 
8.2.1  Error Messages 
 
ERR000001: File <File_Name> does not exist. 
This error occurs, if the input <File_Name> is not found. 
 
ERR000002: Name of the Generation Tool Configuration XML File is 

28 
 

Messages                                                                                                                              Chapter 8 
not given along with <-C/-CONFIG> option. 
This error occurs, if the name of the Generation Tool Configuration XML File 
is not given along with <-C/-CONFIG> option. 
 
ERR000003: File <File name> is not as per XML standard. 
 
This error will occur, if the input <File name> is not as per XML standard. 
 
ERR000004: Cannot open the <Log file name> file. 
 
This error will occur, if unable to open the <Log file name> file. 
 
ERR000005: Name of output directory is not given along with <-O/- 
OUTPUT> option. 
 
This error will occur, if the output directory name is not given along with <-
O/- OUTPUT> option. 
 
ERR000006: Name of output directory is not given in OUTPUT-PATH 
tag in <File name>. 
 
This error will occur, if the output directory is not given in OUTPUT-PATH 
tag in configuration file. 
 
ERR000007: The Generation Tool expects inputs.  
This error will occur, if Only specified Module Specific DLL path in the 
command line without default configuration file. 
 
ERR000008: The option <option> is not supported by the Generation 
Tool. The Generation Tool supports <-O/-OUTPUT, -Osrc , -Oinc, -H/-
HELP, -L/-LOG, -C/-CONFIGFILE and -D/-DRYRUN>" options. 
 
This error will occur, if the invalid <option> is provided to the tool. 
 
ERR000009: Invalid output directory name <output directory name> as 
the file with same name exists. 
 
This error will occur, if the <output directory name> already exists. 
 
ERR000010: Invalid output directory name <output directory name> 
Directory name should not contain any of \*\?\"\|\: characters. 
 
This error will occur, if the <output directory name> path contains junk 
character. 
 
ERR000011: ECU Configuration Description File is not provided as 
input to the Generation Tool. 
 
This error will occur, if the ECU Configuration Description File is not given in 
the command line or in configuration file. 
 
ERR000012: The input <File name> is not as per XML standard. 
Provide the ECU Configuration Description File as input on the 
command line. 
 
This error will occur, if the ECU Configuration Description File is not as per 
XML standard. 
 
ERR000014: 'TRANSLATION-FILE-PATH' tag in <File name> is empty.  
This error will occur, if the translation <File name> doesn’t have  
“TRANSLATION-FILE-PATH‟ tags. 
 
ERR000015: The 'device_name' tag should be present as child of 
'TRANSLATION-FILE-PATH'' tag in <File name>. 
 
This error will occur, if the device mentioned in ECU Configuration 
Description File is not present in “TRANSLATION-FILE-PATH‟ tag in the 
<File name> 
 
ERR000016: ‘DEVICE-FILE-PATH’ tag in <File name> is empty.  
29 
 

Chapter 8                                                                                                                              Messages 
This error will occur, if the translation file <File name> doesn’t have 
“DEVICE- FILE-PATH‟ tags. 
 
ERR000017: The 'device_name’ tag should be present as child of 
‘DEVICE-FILE-PATH' tag in <File name>. 
 
This error will occur, if the device mentioned in ECU Configuration 
Description File is not present in “DEVICE-FILE-PATH‟ tag. 
 
ERR000018: Cannot create directory <output directory name>.  
This error will occur, if unable to create output directory <output directory 
name>. 
 
ERR000019: Cannot open <File name>.  
This error will occur, if unable to open <File name>. 
 
ERR000020: The macro label <macro label> should be unique in 
<translation file name> translation C Header File. 
 
This error will occur, if macro label is not unique in translation C Header 
File. 
 
ERR000021: The macro definition for <macro label> macro is not 
found in <translation file name> translation C Header File. The macro 
label format should be <label format>. 
 
This error will occur, if macro definition is not found in translation C Header 
File. 
 
ERR000022: The macro value for <macro label> macro is empty in 
<translation file name> translation C Header File. 
 
This error will occur, if macro label value is empty in translation C Header 
File. 
 
ERR000023: The macro definition for <macro value> macro is not 
found in input device specific C Header File(s). 
 
This error will occur, if macro definition is not found in input device specific 
C Header File(s). 
 
ERR000024: The macro value for <macro value> macro is empty in 
input device specific C Header File(s). 
 
This error will occur, if macro value is empty in input device specific C 
Header File(s). 
 
ERR000025: Path <Configured Reference Path> provided for Bsw 
Module is incorrect. 
 
This error will occur, if the reference provided for Bsw Module Component is 
incorrect. 
 
ERR000026: BSWMDT content is not present in the input file(s) for 
‘<Module Name>’ module. 
 
This error will occur, if the module specific BSWMDT content is not present 
in the input files. 
 
ERR000027: <MSN> BSWMDT File of either AUTOSAR R3.2 or R4.0 
should be given as input. 
 
This error will occur, if the both R3.2 and R4.0 BSWMDT file given to the 
input to the generation tool. 
 
ERR000028: 'MODULE-DESCRIPTION-REF' element should be present 
in the description file of '<Module Name>' module. 
 
This error will occur, if the MODULE-DESCRIPTION-REF element is not 
present module specific description file. 
30 
 

Messages                                                                                                                              Chapter 8 
 
ERR000029: AUTOSAR version of BSWMDT File and Module 
Description File is different. 
 
This error will occur, if the AUTOSAR version of the BSWMDT File and 
module description file is different. 
 
Remark  Apart from the above error codes DLL will generates some additional 
Module Specific errors during the execution. 
8.2.2  Warning Messages 
 
WRN000001: As per AUTOSAR ECU Configuration Description File 
naming convention, the file extension should be '.arxml' for file. 
 
This warning will occur, if ECU Configuration Description files having an 
extension other than ‟.arxml‟. 
 
8.2.3  Information Messages 
 
INF000001: DLL Version: 
 
This is to display DLL Version of specified module specific DLL. 
 
INF000002: Command line arguments:  
This is to display the DLL arguments received from the Tool. 
 
INF000003: The valid inputs are provided below.  
This information will occur, if the DLL option is not given. (I.e. only provide 
Module DLL Path as command line arguments) 
 
INF000004: Opened file <filename> at <time>.  
This information will occur, during opening the file. 
 
INF000005: Error(s) and Warning(s) detected.  
This information will display the number of errors and warnings. 
INF000006: Execution completed successfully.  
This information will occur, if the execution completed successfully. 
 
INF000007: Execution completed successfully with warnings. 
 
This information will occur, if the execution completed successfully with 
warnings. 
 
INF000008: Execution terminated due to command line errors.  
This information will occur, if the execution terminated due to command line 
errors. 
 
INF000009: Execution terminated due to error in the input file.  
This information will occur, if the execution terminated due to error in the 
input file. 
 
INF000010: Execution terminated due to error, during the structure 
generation in the output file. 
 
This information will occur, if the execution terminated during structure 
generation in output file. 
 
 
8.3. 
R3.2.2 Messages 
 
This section contains the list of error/warning/information messages which is 
specific to AUTOSAR Renesas R3.2.2 X1x MCAL Driver module that will be 
generated during the Module Specific DLL execution. 
31 
 

Chapter 8                                                                                                                              Messages 
 
8.3.1  Error Messages 
 
ERR000030: The 'parameter tag name' tag should be configured in 
BSWMDT File. 
 
This error will occur, if any of the configuration parameter(s) mentioned 
below is (are) not configured in BSWMDT File.  
 
The list of mandatory parameters with respect to container is listed below: 
 
Table 8.1 R3.2.2 BSWMDT Mandatory Parameters 
Container 
Parameters 
BswImplementation 
SW-MAJOR-VERSION 
 
SW-MINOR-VERSION 
 
SW-PATCH-VERSION 
 
AR-MAJOR-VERSION 
 
AR-MINOR-VERSION 
 
AR-PATCH-VERSION 
 
VendorApiInfix 
 
BswModuleDescription 
ModuleId 
 
 
 
Note: VendorApiInfix parameter is mandatory for only some modules. 

 
8.3.2  Warning Messages 
 
None. 
 
8.3.3  Information Messages 
 
None. 
 
8.4. 
R4.0.3 Messages 
 
 
This section contains the list of error/warning/information messages which is 
specific to AUTOSAR Renesas R4.0.3 X1x MCAL Driver module that will be 
generated during the Module Specific DLL execution. 
 
8.4.1  Error Messages 
 
ERR000030: The 'parameter tag name' tag should be configured in 
BSWMDT File. 
 
This error will occur, if any of the configuration parameter(s) mentioned 
below is (are) not configured in BSWMDT File.  
32 
 

Messages                                                                                                                              Chapter 8 
 
The list of mandatory parameters with respect to container is listed below: 
 
 
Table 8.2 R4.0.3 BSWMDT Mandatory Parameters 
Container 
Parameters 
BswImplementation 
SwVersion 
 
 
VendorId  
 
ArReleaseVersion  
 
VendorApiInfix  
 
BswModuleDescription  
ModuleId  
 
 
 
Note: VendorApiInfix parameter is mandatory for only some modules. 

 
8.4.2  Warning Messages 
 
None. 
 
8.4.3  Information Messages 
 
None. 
33 
 

Chapter 8                                                                                                                              Messages 
 
 
34 
 

Notes                                                                                                                                     Chapter 9 
Chapter 9  
Notes 
 
 
 
 
“Tool” terminology is used interchangeably to refer RUCG Tool. 
35 
 

Chapter 9                                                                                                                                    Notes 
 
36 
 

Appendix                                                                                                                             Chapter 10 
Chapter 10    Appendix 
 
 
•  Translation XML File 
 
 
Translation XML File content format shall be given as mentioned below: 
 
<?xml version="1.0" encoding="UTF-8"?> 
<!-- 
The tag PATH-DETAILS should not be renamed since it is top level 
element. 
--> 
<PATH-DETAILS> 
<!-- 
TRANSLATION-FILE-PATH should contain the path of the translation 
header file. The tag TRANSLATION-FILE-PATH should not be 
renamed. Only respective value should be updated for the translation 
header file. 
--> 
<TRANSLATION-FILE-PATH> 
<value_of_MsnDeviceName>Path</value_of_MsnDeviceName> 
</TRANSLATION-FILE-PATH> 
<!-- 
The tags present in DEVICE-FILE-PATH tag should contain the path 
of the device specific C Header File. 
The tags present in DEVICE-FILE-PATH should be equal to the value for 
parameter 
MsnDeviceName present in MsnGeneral container. The 
tag DEVICE-FILE-PATH should not be renamed. 
 
If multiple device header files need to provide for same device then 
each file name should be separated with space. 
--> 
<DEVICE-FILE-PATH> 
<value_of_MsnDeviceName>Path</value_of_MsnDeviceName> 
</DEVICE-FILE-PATH> 
</PATH-DETAILS> 
 
37 
 

Chapter 10                                                                                                                              Appendix 
 
•  Configuration XML File 
 
 
 
Configuration XML File content format shall be given as mentioned below: 
 
 
<?xml version=”1.0” encoding="UTF-8"?> 
--> 
<!-- 
None of the tag from this XML should be renamed or deleted. 
--> 
<XML> 
<!-- Supported Command Line options<OPTION> 
<!-- Only ON or OFF should be provided. --> 
<HELP>ON/OFF</HELP> 
 
 
<!-- Only ON or OFF should be provided. --> 
<LOG>ON/OFF</LOG> 
 
 
<!-- Only ON or OFF should be provided. --> 
<DRYRUN>ON/OFF</DRYRUN> 
 
 
<!-- Only ON or OFF should be provided. --> 
<OUTPUT>OFF</OUTPUT> 
 
 
<!-- Name of output directory --> 
<OUTPUT-PATH>Path</OUTPUT-PATH> 
</OPTION> 
 
 
<!-- To provide input files. If multiple input files need to be 
provided then each file should be separated with ",". --> 
<INPUT-FILE>Path</INPUT-FILE> 
</XML> 
 
 
38 
 

Appendix                                                                                                                             Chapter 10 
 
 
•  PerlCtrl Template 
 
Module Specific dll can be created by using PerlCtrl utility. PerlCtrl accepts 
the perl scripts which consists implementation of generating module specific 
configuration files with correct perlCtrl template. 
 
PerlCtrl Template content shall be given as mentioned below: 
 
=pod 
     
=begin PerlCtrl 
     
        %TypeLib = ( 
            PackageName     => 'MsnCtrl', 
            TypeLibGUID     => '{52093072-B5B3-413B-B4CF-
ACD3E3AAFE7A}', # do NOT edit this line 
            ControlGUID     => '{1D887D1B-E692-4F8B-8552-F6957BB8B834}', 
# do NOT edit this line either 
            DispInterfaceIID=> '{CFC0FF40-EAE4-49C8-8720-
850170DB1ADD}', # or this one 
            ControlName     => 'MsnVeryOwnControl', 
            ControlVer      => 1,  # increment if new object with same ProgID 
                                   # create new GUIDs as well 
            ProgID          => 'MsnCtrl.Control', 
            DefaultMethod   => 'main', 
            Methods         => { 
                'main' => { 
                        DocString           => "The main() method", 
                        HelpContext         => 10, 
                        RetType             =>  VT_I4, 
                        TotalParams         =>  1, 
                        NumOptionalParams   =>  0, 
                        ParamList           =>[ 'cmd_input' => VT_BSTR ] 
                    }, 
                },  # end of 'Methods' 
            Properties      => { 
                },  # end of 'Properties' 
            );  # end of %TypeLib 
     
=end PerlCtrl 
     
=cut 
 
39 
 

Chapter 10                                                                                                                              Appendix 
 
 
40 
 

 
Revision History 
 
 
 
Sl.No.  Description 
Version 
Date 

Initial Version 
1.0.0 
7-Nov-2015 

Section 3.1 and 8.1 are updated as per the new enhancement 
1.1.0 
12-Dec-2015 
feature requirements (EAAR_PN0089_FR_0018, 
EAAR_PN0089_FR_0019, EAAR_PN0089_NR_0010). 

Reference section is updated with correct document name. 
1.1.1 
7-Apr-2016 

R-Number corrected for the document 
1.1.2 
13-Jul-2016 

Following changes are made, 
1.1.3 
17-Feb-2017 
1. Updated notice and copyright information. 
2. Updated R Number. 
41 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
RUCG Tool User's Manual V1.1.3 
 
Publication Date: Rev.1.01, February 17, 2017 
 
Published by: Renesas Electronics Corporation 
 
 
 
 


 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
SALES  OFFICES 
 
http://www.renesas.com 
Refer  to "http://www.renesas.com/" for the latest  and  de  tailed  information. 
Renesas Electronics America Inc. 
2801 Scott Boulevard Santa Clara, CA 95050-2549, U.S.A. 
Tel: +1-408-588-6000, Fax: +1-408-588-6130 
Renesas Electronics Canada Limited 
9251 Yonge Street, Suite 8309 Richmond Hill, Ontario Canada L4C 9T3 
Tel: +1-905-237-2004 
Renesas Electronics Europe Limited 
Dukes Meadow, Millboard Road, Bourne End, Buckinghamshire, SL8 5FH, U.K 
Tel: +44-1628-585-100, Fax: +44-1628-585-900 
Renesas Electronics Europe GmbH 
Arcadiastrasse 10, 40472 Düsseldorf, Germany 
Tel: +49-211-6503-0, Fax: +49-211-6503-1327 
Renesas Electronics (China) Co., Ltd. 
Room 1709, Quantum Plaza, No.27 ZhiChunLu Haidian District, Beijing 100191, P.R.China 
Tel: +86-10-8235-1155, Fax: +86-10-8235-7679 
Renesas Electronics (Shanghai) Co., Ltd. 
Unit 301, Tower A, Central Towers, 555 Langao Road, Putuo District, Shanghai, P. R. China 200333 
Tel: +86-21-2226-0888, Fax: +86-21-2226-0999 
Renesas Electronics Hong Kong Limited 
Unit 1601-1611, 16/F., Tower 2, Grand Century Place, 193 Prince Edward Road West, Mongkok, Kowloon, Hong Kong 
Tel: +852-2265-6688, Fax: +852 2886-9022 
Renesas Electronics Taiwan Co., Ltd. 
13F, No. 363, Fu Shing North Road, Taipei 10543, Taiwan 
Tel: +886-2-8175-9600, Fax: +886 2-8175-9670 
Renesas Electronics Singapore Pte. Ltd. 
80 Bendemeer Road, Unit #06-02 Hyflux Innovation Centre, Singapore 339949 
Tel: +65-6213-0200, Fax: +65-6213-0300 
Renesas Electronics Malaysia Sdn.Bhd. 
Unit 1207, Block B, Menara Amcorp, Amcorp Trade Centre, No. 18, Jln Persiaran Barat, 46050 Petaling Jaya, Selangor Darul Ehsan, Malaysia 
Tel: +60-3-7955-9390, Fax: +60-3-7955-9510 
Renesas Electronics India Pvt. Ltd. 
No.777C, 100 Feet Road, HAL II Stage, Indiranagar, Bangalore, India 
Tel: +91-80-67208700, Fax: +91-80-67208777 
Renesas Electronics Korea Co., Ltd. 
12F., 234 Teheran-ro, Gangnam-Gu, Seoul, 135-080, Korea 
Tel: +82-2-558-3737, Fax: +82-2-558-5141 
 
 
 
 
 
© 2006-2017 Renesas  Electronics  Corporation.  All rights reserved. 
Colophon  4.1 
 



 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
RUCG Tool 
 
User’s Manual 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
       
 
R20UT3754EJ0101 
 
 
 

Document Outline