1 - CF010A_GmTqArbn_Design_PeerReviewChkList

Nexteer_Template_V1.0

Overview

Peer Review Instructions
Technical Review Checklist
Template Change Log


Sheet 1: Peer Review Instructions

Instructions for Functional Design Package Peer Review




PRE-MEETING


Function OwnerConfirm that requirements are reviewed and approved PRIOR to the FDP peer review

Function OwnerStart with latest version of the template for any "first reviews" - Continue to use existing temmplate for re-reviews

Function OwnerProvide the functional design package (changed documents) to the invited attendees 1-2 working days in advance of review

Function OwnerNotify the assigned peer reviewer and make sure they are prepared to do their function in the meeting

Function OwnerIdentify necessary attendance and invite to meeting

Function OwnerComplete the "Author" column information for sections 1 through 5 prior to the review

Function OwnerComplete the attendance invitation list in section 7

Function OwnerFor Re-reviews only: Complete the column "remarks by author" to identify actions taken to address items found in earlier reviews.



DURING MEETING


Function OwnerPresent document changes to the review team

Peer ReviewerCapture attendance of the review

Peer ReviewerCapture actions and issues in section 6. Identify issue summary, Document type, Reference (Requirement ID, section number, etc), Defect Type and indicate status as "OPEN"



POST MEETING


Function OwnerFollow up on all "open" items. Update "Summary of Resolution" to indicate what was done or decided.

Function OwnerSchedule follow up review OR review open items with peer reviewer and obtain agreement to close

Peer ReviewerClose change request in system and confirm all associated tasks are complete. Upload peer review checklist (this document) with any FDP updates

Sheet 2: Technical Review Checklist

Technical Review Checklist - Template Version 02.02.00







Product NameElectric Power SteeringElectrical Arch.4Review ScopeDefect TypeNumbers




YesClosedFR
Function IDCF010A_GmTqArbn

EA4#6887
- Removed condition "Handwheel Angle Servo Enable = true' for setting Desired LKA Torque Command to Zero
in Determine Desired Value subsystem.
- Monotony for 'GmTqArbnLkaSlewY' calibration has been set to 'None'.
Requirement0




NoRejectedFDD
Long NameGM Torque Arbitration

Interface0




NAOpenModel
Version that you started from. NOT the version you hope to release. If this will be v1.0.0, enter NA. Starting Baseline2.1.0EffortDesign0






FMEA
AuthorSivaReview Effort(Hrs.)
Standards0






*.m File


Corr+Verf effort(Hrs.)
Documentation0






Cal Process


Total Effort (Hrs.)0.00Others0













Total0







Checklist No.Description of CheckAuthor: This column is for Self review. Author shall fill Yes/No/NA against each point in checklist. AuthorAuthor: This column is for reviewer. Reviewer shall fill Yes/No/NA against each point in checklist. ReviewerAuthor: Detailed Description of the finding shall be provided by the reviewer. Description of finding by reviewerAuthor: Defect type to be selected. Defect TypeAuthor: What action is taken to fix the comment & other remarks need to be filled by author. Remarks By AuthorAuthor: Data in this column shall be filled by reviewer after checking whether the rework is completed. Status







1Section 1: Data Dictionary














Is Filename of Data Dictionary in correct format?YesYes












Is the FDD.Version property correctly updated?YesYes












Is the Data Dictionary Verification report error free?YesYes












Does FDD Long Name, Short Name, and Description match requirements?YesYes












Are all runnables defined?YesYes












Do runnables have the correct time step?YesYes












Do server runnables correctly define arguments?NANA












Are all clients defined?NANA












Do client definitions match the corresponding server runnable?NANA












Does name and metadata of every signal match its corresponding interface signal?YesYes












Do output signal ranges match requirements (check DOOR min/max attributes too)?YesYes












Are calibration tables named correctly (e.g. AssiX and AssiY)?YesYes












Are all data types represented by released Data_Management classes?YesYes












Do all calibrations have correct values for all metadata?YesYes












Is NVM defined in the appropriate number of blocks?NANA












Are constants defined with proper scope (local vs global)?YesYes












Are all dependent constants and calibrations included in one file?YesYes












Does FDD.DesignASIL match requirements?YesYes



























2Section 2: ModelAuthor: This column is for Self review. Author shall fill Yes/No/NA against each point in checklist. AuthorAuthor: This column is for reviewer. Reviewer shall fill Yes/No/NA against each point in checklist. ReviewerAuthor: Detailed Description of the finding shall be provided by the reviewer. Description of finding by reviewerAuthor: Defect type to be selected. Defect TypeAuthor: What action is taken to fix the comment & other remarks need to be filled by author. Remarks By AuthorAuthor: Data in this column shall be filled by reviewer after checking whether the rework is completed. Status








Is filename of model in correct format?YesYes












Is Top level of model annotated with Requirements Baseline?YesYes












Is the Top level of the model annotated with Tool Dependencies?YesYes












Is Top level of model annotated with Change Log or History?YesYes












Is the 2nd level of model free from subsystems that are not Function-Call Subsystems?YesYes












Is the 2nd level of model free from arithmetic and logic operations?YesYes












Are the Runnable trigger signals named as "call_<Runnable>"?YesYes












Does 2nd level of model have a properly updated annotation with name, description, and intended baseline number?YesYes












Are all data flow layers free of Function-Call Subsystems and Memory Store blocks?YesYes












Does the Model have the confidentiality and copyright information inside all its Subsystems?YesYes












Are all the Memory Store blocks for PIM and Display Variables located on the 2nd level of model?YesYes












Is each diagnostic (NTC) capable of being set to "PASS"?NANA












Does non-zero intialization of PIM occur in the function's Init runnable?NANA












Does design properly include Set Ram Block Status when NVM RAM values change?NANA












Does model include appropriate logic for dealing with missing or corrupted NVM data?NANA












Does model execute without errors/warnings after loading NxtrMBDConfig configuration set?YesYes



























3Section 3: Requirements LinkingAuthor: This column is for Self review. Author shall fill Yes/No/NA against each point in checklist. AuthorAuthor: This column is for reviewer. Reviewer shall fill Yes/No/NA against each point in checklist. ReviewerAuthor: Detailed Description of the finding shall be provided by the reviewer. Description of finding by reviewerAuthor: Defect type to be selected. Defect TypeAuthor: What action is taken to fix the comment & other remarks need to be filled by author. Remarks By AuthorAuthor: Data in this column shall be filled by reviewer after checking whether the rework is completed. Status








Are all requirements links of the format <FDDNumber>_<ObjectID>?NANA

Since none of the requirements were linked to design there is no Requirements traceability report.









Does requirements HTML report reference only the DOORS module of this component for all links in the design?NANA

Since none of the requirements were linked to design there is no Requirements traceability report.









Are linked blocks linked to the correct requirements(s)? (watch for problems due to copy/pasted blocks)NANA

Since none of the requirements were linked to design there is no Requirements traceability report.









Is the list of unlinked blocks acceptable?NANA

Since none of the requirements were linked to design there is no Requirements traceability report.
























4Section 4: Model AdvisorAuthor: This column is for Self review. Author shall fill Yes/No/NA against each point in checklist. AuthorAuthor: This column is for reviewer. Reviewer shall fill Yes/No/NA against each point in checklist. ReviewerAuthor: Detailed Description of the finding shall be provided by the reviewer. Description of finding by reviewerAuthor: Defect type to be selected. Defect TypeAuthor: What action is taken to fix the comment & other remarks need to be filled by author. Remarks By AuthorAuthor: Data in this column shall be filled by reviewer after checking whether the rework is completed. Status








Was Model Advisor run with the correct configuration settings?YesYes












Is the Model Advisor rerport free from "Fails".YesYes












Are Model Advisor report "Warnings" acceptable?YesYes



























5Section 5: Delivery PackageAuthor: This column is for Self review. Author shall fill Yes/No/NA against each point in checklist. AuthorAuthor: This column is for reviewer. Reviewer shall fill Yes/No/NA against each point in checklist. ReviewerAuthor: Detailed Description of the finding shall be provided by the reviewer. Description of finding by reviewerAuthor: Defect type to be selected. Defect TypeAuthor: What action is taken to fix the comment & other remarks need to be filled by author. Remarks By AuthorAuthor: Data in this column shall be filled by reviewer after checking whether the rework is completed. Status








Does Design folder contain only the model, data dictionary, and (optionally) a simulation setup script?YesYes












Does Doc folder contain a zipped HTML webview model?YesYes












Was webview model created without requirements highlighted?YesYes












Does Reports folder contain only the data dictionary verification report, Model Advisor report, and zipped requirements traceability report?NoNo

Since none of the requirements were linked to design there is no Requirements traceability report.
























4Section 6: Other Issus/Actions IdentifiedDocumentReferenceSummary of resolutionAuthor: Defect type to be selected. Defect TypeAuthor: What action is taken to fix the comment & other remarks need to be filled by author. Remarks By AuthorAuthor: Data in this column shall be filled by reviewer after checking whether the rework is completed. Status







4.1














4.2














4.3














4.4














4.5














4.6














4.7














4.8














4.9














4.10














4.11














4.12














4.13














4.14














4.15














4.16














4.17














4.18














4.19














4.20














4.21














4.22














4.23














4.24














4.25














5Section 7: APPROVALS













RoleFirst ReviewDateAttendanceApproval?










Function Owner*Matt Tompkins8/19/2016YesYes










Peer Reviewer*PriceYesYes










Safety<Name - if invited>












SoftwareNick SaxtonYesYes










ESG / SystemsSiva, SudeepYesYes










EPDT / CSE<Name - if invited>












Hardware<Name - if invited>












Test<Name - if invited>












RoleSecond Review (if required)DateAttendanceApproval?










Function Owner*<Owner Name>













Peer Reviewer*<Name>












Safety<Name - if invited>












Software<Name - if invited>












ESG / Systems<Name - if invited>












EPDT / CSE<Name - if invited>












Hardware<Name - if invited>












Test<Name - if invited>












RoleThird Review (if required)DateAttendanceApproval?










Function Owner*<Owner Name>













Peer Reviewer*<Name>












Safety<Name - if invited>












Software<Name - if invited>












ESG / Systems<Name - if invited>












EPDT / CSE<Name - if invited>












Hardware<Name - if invited>












Test<Name - if invited>












RoleFourth Review (if required)DateAttendanceApproval?










Function Owner*<Owner Name>













Peer Reviewer*<Name>












Safety<Name - if invited>












Software<Name - if invited>












ESG / Systems<Name - if invited>












EPDT / CSE<Name - if invited>












Hardware<Name - if invited>












Test<Name - if invited>












RoleAdd more if necessaryDateAttendanceApproval?










































P.S.:Yes indicates adherence














No indicates non-adherence, reviewer shall provide suitable comments at the end of this document for each point.














NA indicates not applicable














Sheet 3: Template Change Log

RevChangeAuthor
01.00.05Added lesson learned #3.5MDK
01.00.06Added lesson learned #3.6, 3.7 - Structure and writing of NVM in mfiles and models.MDK
02.00.00Combined ESG and Systems into one, compatible with Data_Management 2.13.0 of CreateDD and VerifyDD.K. Derry
02.01.00Added: Does FDD.DesignASIL match requirements?
Added: Was webview model created without requirements highlighted?
Removed: Redundant row in Data Dictionary section.
Formatting: Column C now consistently center-justified.
K. Derry
02.02.00Added: Are all data types represented by released Data_Management classes?
Removed: Are all runnables defined? Rationale: Automated tools checking.
Removed: Does the Component shortname match data dictionary FDD metadata?
Removed: "Data store name must resolve to Simulink signal object"
Edited: Model Advisor report should now be left unzipped.
K. Derry











































































2 - CF010A_GmTqArbn_ModelAdvisor_Report

Model Advisor Report for 'CF010A_GmTqArbn'
Model Advisor Report - CF010A_GmTqArbn.slx
Simulink version: 8.2Model version: 1.71
System: CF010A_GmTqArbnCurrent run: 19-Aug-2016 12:22:07
 Model Advisor configuration: ...NxtrModelAdvisorConfig.mat

Run Summary
PassFailWarningNot RunTotal
   52   0   15   292359


Model Advisor

    By Product

        Simulink

        Simulink Coder


        Embedded Coder


        Simscape


        Simulink Verification and Validation

            Modeling Standards

                DO-178C/DO-331 Checks


                IEC 61508, ISO 26262, and EN 50128 Checks


                MathWorks Automotive Advisory Board Checks


            Requirements Consistency


        Simulink Control Design


    By Task

        Code Generation Efficiency


 Check optimization settings

You should turn on the following optimization(s):

  • Block reduction
  • Remove code from floating-point to integer conversions that wraps out-of-range values
  • Inline invariant signals
  • The Simulation range checking diagnostic is enabled. Because this diagnostic can increase the time it takes to simulate your model, you should consider turning it off, by setting its value to none.
  • Ignore testpoints when generating code
  • Pass reusable subsystem outputs as individual arguments



  •         Frequency Response Estimation


            Managing Data Store Memory Blocks


            Managing Library Links And Variants


            Model Referencing


            Modeling Guidelines for MISRA-C:2004

            Modeling Physical Systems


            Modeling Signals and Parameters using Buses


            Modeling Single-Precision Systems


            Modeling Standards for DO-178C/DO-331


            Modeling Standards for EN 50128


            Modeling Standards for IEC 61508


            Modeling Standards for ISO 26262


     Display model metrics and complexity report

    Display number of elements and name, level, and depth of subsystems for the model or subsystem

    Model metrics information
    Display number of elements for Simulink blocks and Stateflow constructs


    Summary

    Element TypeCount
    Inport150
    Outport91
    SubSystem79


    Simulink

    Block TypeCount
    Inport150
    Ground112
    Terminator112
    Outport91
    SubSystem79
    Constant56
    ActionPort28
    S-Function26
    If14
    Merge14
    Sum11
    UnaryMinus11
    DataStoreWrite10
    From10
    Product9
    DataStoreMemory8
    RelationalOperator8
    Goto5
    Math4
    DataStoreRead4
    Logic3
    TriggerPort2
    Step2
    EnablePort2
    ∧ Less

    Model complexity information
    Display name, level, and depth of subsystems


    Maximum Subsystem Depth: 5

    Subsystem Depth

    Subsystem NameLevelDepth
    CopyRight211
    GmTqArbn14
    GmTqArbn/CopyRight221
    GmTqArbn/GmTqArbnInit122
    GmTqArbn/GmTqArbnInit1/ApaSmotngHwTqLoPassFil31
    GmTqArbn/GmTqArbnInit1/CopyRight231
    GmTqArbn/GmTqArbnPer123
    GmTqArbn/GmTqArbnPer1/CAN Conditioning32
    GmTqArbn/GmTqArbnPer1/CAN Conditioning/CopyRight241
    GmTqArbn/GmTqArbnPer1/CAN Conditioning/THEN141
    GmTqArbn/GmTqArbnPer1/CAN Conditioning/THEN241
    GmTqArbn/GmTqArbnPer1/CAN Conditioning/THEN341
    GmTqArbn/GmTqArbnPer1/CAN Conditioning/THEN441
    GmTqArbn/GmTqArbnPer1/CopyRight231
    GmTqArbn/GmTqArbnPer1/Determine Desired Value32
    GmTqArbn/GmTqArbnPer1/Determine Desired Value/CopyRight241
    GmTqArbn/GmTqArbnPer1/Determine Desired Value/LimDyn_f3241
    GmTqArbn/GmTqArbnPer1/Determine Desired Value/THEN341
    GmTqArbn/GmTqArbnPer1/Determine Desired Value/THEN441
    GmTqArbn/GmTqArbnPer1/ESC logic32
    GmTqArbn/GmTqArbnPer1/ESC logic/CopyRight241
    GmTqArbn/GmTqArbnPer1/ESC logic/LimDyn_f3241
    GmTqArbn/GmTqArbnPer1/ESC logic/THEN341
    GmTqArbn/GmTqArbnPer1/ESC logic/THEN441
    GmTqArbn/GmTqArbnPer1/ESC logic/THEN741
    GmTqArbn/GmTqArbnPer1/ESC logic/THEN841
    GmTqArbn/GmTqArbnPer1/LimDyn_f131
    GmTqArbn/GmTqArbnPer1/LimDyn_f231
    GmTqArbn/GmTqArbnPer1/LimDyn_f331
    GmTqArbn/GmTqArbnPer1/LimDyn_f3231
    GmTqArbn/GmTqArbnPer1/LimDyn_f3231
    GmTqArbn/GmTqArbnPer1/LimDyn_f431
    GmTqArbn/GmTqArbnPer1/LimDyn_f531
    GmTqArbn/GmTqArbnPer1/PosnServo_Smoothed_Ramp32
    GmTqArbn/GmTqArbnPer1/PosnServo_Smoothed_Ramp/CopyRight241
    GmTqArbn/GmTqArbnPer1/PosnServo_Smoothed_Ramp/FilLpUpdOutp141
    GmTqArbn/GmTqArbnPer1/PosnServo_Smoothed_Ramp/FixdToFloat_f32_u141
    GmTqArbn/GmTqArbnPer1/PosnServo_Smoothed_Ramp/FixdToFloat_f32_u1641
    GmTqArbn/GmTqArbnPer1/PosnServo_Smoothed_Ramp/RateLimDyn_f141
    GmTqArbn/GmTqArbnPer1/PosnServo_Smoothed_Ramp/THEN141
    GmTqArbn/GmTqArbnPer1/PosnServo_Smoothed_Ramp/THEN241
    GmTqArbn/GmTqArbnPer1/PosnServo_Smoothed_Ramp/THEN341
    GmTqArbn/GmTqArbnPer1/PosnServo_Smoothed_Ramp/THEN441
    GmTqArbn/GmTqArbnPer1/PosnServo_Smoothed_Ramp/THEN541
    GmTqArbn/GmTqArbnPer1/PosnServo_Smoothed_Ramp/THEN641
    GmTqArbn/GmTqArbnPer1/Ramp to Value32
    GmTqArbn/GmTqArbnPer1/Ramp to Value/CopyRight241
    GmTqArbn/GmTqArbnPer1/Ramp to Value/FixdToFloat_f32_u1641
    GmTqArbn/GmTqArbnPer1/Ramp to Value/RateLimDyn_f3241
    GmTqArbn/GmTqArbnPer1/Ramp to Value/THEN141
    GmTqArbn/GmTqArbnPer1/Ramp to Value/THEN241
    GmTqArbn/GmTqArbnPer1/Ramp to Value/THEN341
    GmTqArbn/GmTqArbnPer1/Ramp to Value/THEN441
    GmTqArbn/GmTqArbnPer1/THEN131
    GmTqArbn/GmTqArbnPer1/THEN231
    GmTqArbn/GmTqArbnPer1/THEN331
    GmTqArbn/GmTqArbnPer1/THEN431
    GmTqArbn/GmTqArbnPer1/THEN531
    GmTqArbn/GmTqArbnPer1/THEN631
    GmTqArbn/GmTqArbnPer1/THEN731
    GmTqArbn/GmTqArbnPer1/THEN831
    call_GmTqArbnInit112
    call_GmTqArbnInit1/Subsystem521
    call_GmTqArbnPer112
    call_GmTqArbnPer1/Subsystem521
    ∧ Less



     Check for root Inports with missing properties

    Identify Inport blocks in the top-level of the model with missing or inherited sample times, data types, or port dimensions

    Warning
    The following Inport blocks have undefined or inherited sample times, data types or port dimensions

    InportLinkConditions
    1CF010A_GmTqArbn/VehSpdMaxSecurMissing port dimension
    Missing signal data type
    Missing port sample time
    2CF010A_GmTqArbn/HwTqMissing port dimension
    Missing signal data type
    Missing port sample time
    3CF010A_GmTqArbn/HwAgServoEnaMissing port dimension
    Missing signal data type
    Missing port sample time
    4CF010A_GmTqArbn/MotTqServoCmdMissing port dimension
    Missing signal data type
    Missing port sample time
    5CF010A_GmTqArbn/HwOscnEnaMissing port dimension
    Missing signal data type
    Missing port sample time
    6CF010A_GmTqArbn/HwTqOscCmdMissing port dimension
    Missing signal data type
    Missing port sample time
    7CF010A_GmTqArbn/LkaStMissing port dimension
    Missing signal data type
    Missing port sample time
    8CF010A_GmTqArbn/LkaTqCmdMissing port dimension
    Missing signal data type
    Missing port sample time
    9CF010A_GmTqArbn/EscStMissing port dimension
    Missing signal data type
    Missing port sample time
    10CF010A_GmTqArbn/EscCmdMissing port dimension
    Missing signal data type
    Missing port sample time


    Recommended Action
    Explicitly define all missing Inport block properties identified in the results
    • Missing port dimension: Model contains Inport blocks with inherited port dimension (-1). Specify port dimension for the listed Inport blocks.
    • Missing signal data type: Model contains Inport blocks with inherited data type. Specify a data type for the listed Inport blocks.
    • Missing port sample time: Model contains Inport blocks with inherited sample time (-1). Specify sample time information for the listed Inport blocks. Note: The sample time of root Inports with bus type must match the sample times specified at the leaf elements of the bus object.


     Check for model objects that do not link to requirements

    Check Simulink blocks and Stateflow objects that do not link to a requirements document

    Warning
    The following blocks do not link to a requirement document:

    ∧ Less
    Recommended Action
    For each object in the list, in the Model Editor, right-click the block, select Requirements, and specify a requirement.



            Modeling Standards for MAAB

                Naming Conventions


     Check file names

    Identify file names with incorrect characters or formatting.

    See Also

    Warning
    The following files have incorrect file names:

    File NameIncorrect Character or Format
    EA4#6711.pdfFile name contains incorrect characters. Correct characters are a-z, A-Z, 0-9, and underscore (_).
    ~$CF010A_GmTqArbn_Design_PeerReviewChkList.xlsxFile name contains incorrect characters. Correct characters are a-z, A-Z, 0-9, and underscore (_).


    Recommended Action
    Rename the above files to remove incorrect characters and formatting.


     Check folder names

    Identify folders using incorrect characters and formatting.

    See Also

    Warning
    The following folders have incorrect names:

    FolderIncorrect Character or Format
    +structFolder name contains incorrect characters. Correct characters are a-z, A-Z, 0-9, and underscore (_).


    Recommended Action
    Rename the above folders to remove incorrect characters and formatting.



                Model Architecture


     Check for mixing basic blocks and subsystems

    Identify levels in the model that include basic blocks and subsystems. Each level of a model must be designed with blocks of the same level (for example, only subsystems or only basic blocks).

    See Also

    Warning
    The following level(s) in the model include basic blocks and subsystems:

    SystemBlock path
    CF010A_GmTqArbnCF010A_GmTqArbn/CopyRight2
    CF010A_GmTqArbnCF010A_GmTqArbn/InitTrig
    CF010A_GmTqArbnCF010A_GmTqArbn/PerTrig
    CF010A_GmTqArbn/GmTqArbnCF010A_GmTqArbn/GmTqArbn/CopyRight2
    CF010A_GmTqArbn/GmTqArbn/GmTqArbnPer1..../GmTqArbn/GmTqArbnPer1/Add
    CF010A_GmTqArbn/GmTqArbn/GmTqArbnPer1..../GmTqArbn/GmTqArbnPer1/Constant1
    CF010A_GmTqArbn/GmTqArbn/GmTqArbnPer1..../GmTqArbn/GmTqArbnPer1/Constant10
    CF010A_GmTqArbn/GmTqArbn/GmTqArbnPer1..../GmTqArbn/GmTqArbnPer1/Constant11
    CF010A_GmTqArbn/GmTqArbn/GmTqArbnPer1..../GmTqArbn/GmTqArbnPer1/Constant12
    CF010A_GmTqArbn/GmTqArbn/GmTqArbnPer1..../GmTqArbn/GmTqArbnPer1/Constant13
    CF010A_GmTqArbn/GmTqArbn/GmTqArbnPer1..../GmTqArbn/GmTqArbnPer1/Constant14
    CF010A_GmTqArbn/GmTqArbn/GmTqArbnPer1..../GmTqArbn/GmTqArbnPer1/Constant15
    CF010A_GmTqArbn/GmTqArbn/GmTqArbnPer1..../GmTqArbn/GmTqArbnPer1/Constant16
    CF010A_GmTqArbn/GmTqArbn/GmTqArbnPer1..../GmTqArbn/GmTqArbnPer1/Constant17
    CF010A_GmTqArbn/GmTqArbn/GmTqArbnPer1..../GmTqArbn/GmTqArbnPer1/Constant2
    CF010A_GmTqArbn/GmTqArbn/GmTqArbnPer1..../GmTqArbn/GmTqArbnPer1/Constant3
    CF010A_GmTqArbn/GmTqArbn/GmTqArbnPer1..../GmTqArbn/GmTqArbnPer1/Constant4
    CF010A_GmTqArbn/GmTqArbn/GmTqArbnPer1..../GmTqArbn/GmTqArbnPer1/Constant5
    CF010A_GmTqArbn/GmTqArbn/GmTqArbnPer1..../GmTqArbn/GmTqArbnPer1/Constant6
    CF010A_GmTqArbn/GmTqArbn/GmTqArbnPer1..../GmTqArbn/GmTqArbnPer1/Constant7
    CF010A_GmTqArbn/GmTqArbn/GmTqArbnPer1..../GmTqArbn/GmTqArbnPer1/Constant8
    CF010A_GmTqArbn/GmTqArbn/GmTqArbnPer1..../GmTqArbn/GmTqArbnPer1/Constant9
    CF010A_GmTqArbn/GmTqArbn/GmTqArbnPer1..../GmTqArbn/GmTqArbnPer1/CopyRight2
    CF010A_GmTqArbn/GmTqArbn/GmTqArbnPer1..../GmTqArbn/GmTqArbnPer1/Data Store Write1
    CF010A_GmTqArbn/GmTqArbn/GmTqArbnPer1..../GmTqArbn/GmTqArbnPer1/Data Store Write2
    CF010A_GmTqArbn/GmTqArbn/GmTqArbnPer1..../GmTqArbn/GmTqArbnPer1/Data Store Write3
    CF010A_GmTqArbn/GmTqArbn/GmTqArbnPer1..../GmTqArbn/GmTqArbnPer1/LimDyn_f1
    CF010A_GmTqArbn/GmTqArbn/GmTqArbnPer1..../GmTqArbn/GmTqArbnPer1/LimDyn_f2
    CF010A_GmTqArbn/GmTqArbn/GmTqArbnPer1..../GmTqArbn/GmTqArbnPer1/LimDyn_f3
    CF010A_GmTqArbn/GmTqArbn/GmTqArbnPer1..../GmTqArbn/GmTqArbnPer1/LimDyn_f32
    CF010A_GmTqArbn/GmTqArbn/GmTqArbnPer1..../GmTqArbn/GmTqArbnPer1/LimDyn_f32
    CF010A_GmTqArbn/GmTqArbn/GmTqArbnPer1..../GmTqArbn/GmTqArbnPer1/LimDyn_f4
    CF010A_GmTqArbn/GmTqArbn/GmTqArbnPer1..../GmTqArbn/GmTqArbnPer1/LimDyn_f5
    CF010A_GmTqArbn/GmTqArbn/GmTqArbnPer1..../GmTqArbn/GmTqArbnPer1/THEN1
    CF010A_GmTqArbn/GmTqArbn/GmTqArbnPer1..../GmTqArbn/GmTqArbnPer1/THEN2
    CF010A_GmTqArbn/GmTqArbn/GmTqArbnPer1..../GmTqArbn/GmTqArbnPer1/THEN3
    CF010A_GmTqArbn/GmTqArbn/GmTqArbnPer1..../GmTqArbn/GmTqArbnPer1/THEN4
    CF010A_GmTqArbn/GmTqArbn/GmTqArbnPer1..../GmTqArbn/GmTqArbnPer1/THEN5
    CF010A_GmTqArbn/GmTqArbn/GmTqArbnPer1..../GmTqArbn/GmTqArbnPer1/THEN6
    CF010A_GmTqArbn/GmTqArbn/GmTqArbnPer1..../GmTqArbn/GmTqArbnPer1/THEN7
    CF010A_GmTqArbn/GmTqArbn/GmTqArbnPer1..../GmTqArbn/GmTqArbnPer1/THEN8
    CF010A_GmTqArbn/GmTqArbn/GmTqArbnPer1..../GmTqArbn/GmTqArbnPer1/Unary Minus
    CF010A_GmTqArbn/GmTqArbn/GmTqArbnPer1..../GmTqArbn/GmTqArbnPer1/Unary Minus1
    CF010A_GmTqArbn/GmTqArbn/GmTqArbnPer1..../GmTqArbn/GmTqArbnPer1/Unary Minus2
    CF010A_GmTqArbn/GmTqArbn/GmTqArbnPer1..../GmTqArbn/GmTqArbnPer1/Unary Minus3
    ∧ Less


    Recommended Action
    If possible, replace blocks at the identified level of the model hierarchy with basic blocks. Move nonvirtual blocks into the identified subsystem.



                Model Configuration Options

                Simulink


     Check for Simulink diagrams using nonstandard display attributes

    Identify nonstandard display attributes in Simulink diagrams.

    See Also

    _________________________________________________________________________________________

    Check format settings
    Identify incorrect model-level format options.

    Warning
    The following format display options are incorrect.

    Display AttributeRecommended ValueActual Value
    Display > Signals & Ports > Wide Nonscalar Linesonoff
    View > Model Browser Options > Model Browseroffon


    Recommended Action
    Set the format options to the recommended value.
    _________________________________________________________________________________________

    Check block colors
    Identify blocks using nonstandard colors.

    Warning
    The following blocks use nonstandard colors:

    Recommended Action
    Set the block foreground color to black and the background color to white.
    _________________________________________________________________________________________

    Check canvas colors
    Identify canvases that are not white.

    Passed
    All diagrams use a white canvas.
    _________________________________________________________________________________________

    Check diagram zoom
    Identify diagrams that do not have zoom factor set to 100 %.

    Warning
    The following diagrams do not have zoom factor set to 100 percent:

    ∧ Less
    Recommended Action
    For each listed diagram, select View > Zoom > Normal View (100%).


     Check font formatting

    Identify inconsistent formatting of text.

    See Also

    Warning
    Font formatting is not consistent.

    The following font characteristics are used in the model/subsystem. Font characteristics are sorted by number of occurrences. The most common characteristics are bold.
    Font NameFont SizeFont Style

    Helvetica
    Arial

    10
    9
    14

    normal



    Recommended Action
    To have consistent font formatting, click Modify All Fonts to apply the font formatting selected in the input parameters above to all objects.

    Input Parameters Selection
    NameValue
    Font NameCommon
    Font SizeCommon
    Font StyleCommon


     Check positioning and configuration of ports

    Identify input and output ports with incorrect positioning and configurations.

    See Also

    _________________________________________________________________________________________

    Check Inport blocks position
    Identify Inport blocks that result in left-flowing signals.

    Passed
    There are no Inport blocks in the model that result in left-flowing signals.
    _________________________________________________________________________________________

    Check Outport block position
    Identify Outport blocks that result in left-flowing signals.

    Passed
    There are no Outport blocks in the model that result in left-flowing signals.
    _________________________________________________________________________________________

    Check port orientation
    Identify port blocks with nondefault orientation.

    Passed
    All ports use the default orientation.
    _________________________________________________________________________________________

    Check for duplicate Inports blocks
    Identify duplicate Inport blocks.

    Passed
    All Inport blocks in the model are used once.


     Check visibility of block port names

    Identify port block names that are not uniformly displayed. The block names must all be displayed or none displayed. Library blocks are an exception to this rule. This check ignores masked and subsystem blocks.

    See Also

    _________________________________________________________________________________________

    Check for incorrect port name display
    Identify ports that are incorrectly displaying names.

    Passed
    Subsystem blocks are correctly displayed.
    _________________________________________________________________________________________

    Check for incorrect subsystem port name display
    Identify subsystems that are incorrectly displaying names.

    Passed
    Subsystem blocks are correctly displayed.

    Input Parameters Selection
    NameValue
    Display all port names (Diagram > Format > Show Block Name).true


     Check the display attributes of block names

    Identify whether to display block names.

    See Also

    _________________________________________________________________________________________

    Check for blocks with hidden names and obvious function
    Identify block names that are displayed but can be hidden due to obvious behavior.

    Passed
    All blocks with obvious behavior have hidden names.
    _________________________________________________________________________________________

    Check for non-descriptive displayed block names
    Identify block names that are displayed but should be hidden due to a lack of a descriptive name.

    Passed
    All displayed names provide descriptive information.
    _________________________________________________________________________________________

    Check for missing block names
    Identify block names that are hidden but should be displayed to show a descriptive name.

    Warning
    The following blocks have descriptive names, however, the names are hidden:

    Recommended Action
    Modify the blocks to show the block name (Diagram > Format > Show Block Name).


     Check signal line labels

    Identify blocks that require labeled signals. A subset of source and destination blocks require labeled signals.

    See Also

    _________________________________________________________________________________________

    Check source block labels
    The following source blocks require labeled signals; Inport, From, Data Store Read, Constant, Bus Selector, Demux, Selector. If the signal name is visible on the block, this rule is considered met.

    Warning
    The following signals have no label:

    ∧ Less
    Recommended Action
    Add a new or propagated label to the signal line.
    _________________________________________________________________________________________

    Check destination block labels
    The following destination blocks require labeled signals; Outport, Goto, Data Store Write, Bus Creator, Mux, Subsystem, Chart. If the signal name is visible on the source block, this rule is considered met.

    Warning
    The following signals have no label:

    ∧ Less
    Recommended Action
    Add a new or propagated label to the signal line.


     Check for propagated signal labels

    Identify propagated labels on signal lines.

    See Also

    _________________________________________________________________________________________

    Check subsystem input labels
    Identify subsystem inputs that are labeled and display propagated signals.

    Passed
    All inputs to the subsystem have labels and display propagated signals.
    _________________________________________________________________________________________

    Check subsystem output labels
    Identify outputs from subsystems that are labeled and display signal propagation.

    Passed
    All outputs from the subsystem have labels and display propagated signals.
    _________________________________________________________________________________________

    Signal propagation for nonsubsystem blocks
    Identify the signal propagation status for both transformative and nontransformative blocks.

    Passed
    All outputs from non subsystem blocks correctly use labels and display propagated signals.



                Stateflow


     Check usage of exclusive and default states in state machines

    Identify Stateflow charts and substates that incorrectly use or define exclusive and default states.
    Note: This check does not support charts that use MATLAB as the action language.

    See Also

    _________________________________________________________________________________________

    Check Stateflow charts for exclusive states
    Identify Stateflow charts that have singular exclusive (OR) states.

    Passed
    The Stateflow charts do not have singular exclusive (OR) states.
    _________________________________________________________________________________________

    Check Stateflow charts for undefined default states
    Identify Stateflow charts that do not define default states.

    Passed
    Each Stateflow chart defines a default state.
    _________________________________________________________________________________________

    Check for multiple states assigned as the default state
    At the root level in the Stateflow hierarchy only one state should be assigned as the default.

    Passed
    The root level of the chart has only one default state assigned.
    _________________________________________________________________________________________

    Check for substates with singular OR states
    States configured as OR should always be part of a group of states.

    Passed
    No singular OR states were detected.
    _________________________________________________________________________________________

    Check for substates without default states defined
    At every level in the Stateflow hierarchy a default state should be assigned.

    Passed
    All substates have default states assigned.
    _________________________________________________________________________________________

    Check for substates with multiple default states defined
    At every level in the Stateflow hierarchy only one state should be assigned as the default.

    Passed
    All levels of the chart have only one default state assigned.


     Check transition orientations in flowcharts

    Identify transitions in Stateflow flowcharts that are drawn incorrectly.

    See Also

    _________________________________________________________________________________________

    Check for conditions drawn vertically
    Condition expressions should be drawn on the horizontal segments of flowcharts.

    Passed
    All conditions expressions were drawn horizontally.
    _________________________________________________________________________________________

    Check for action transitions drawn vertically
    Transition actions should be drawn on the vertical segments of flowcharts.

    Passed
    All transitions actions where drawn vertically.
    _________________________________________________________________________________________

    Check for junctions for default transitions
    All Junctions in a flow chart should have a default exit transition.

    Passed
    All Junctions have a default exit transition.
    _________________________________________________________________________________________

    Check for transitions that combine condition and action
    Flowcharts should not combine condition evaluations and action expressions in a single transition.

    Passed
    No combined expressions where found in the chart.



                MATLAB Functions


            Requirements Consistency Checking


            Simulation Accuracy


            Simulation Runtime Accuracy Diagnostics


     Runtime diagnostics for S-functions

    This model contains the following C-MEX S-functions:

    IDS-FunctionBlock
    1C:\KVS\EPS\Nexteer_Tool_Chain_Release\Release_XXJul2016\MFiles\Nexteer_Utilities v4.7.0\EA4_Library\Math\Abslt_f32_f32.mexw64CF010A_GmTqArbn/GmTqArbn/GmTqArbnPer1/ESC logic/Abslt_f32_f32
      CF010A_GmTqArbn/GmTqArbn/GmTqArbnPer1/PosnServo_Smoothed_Ramp/Abslt_f32_f32
    2C:\KVS\EPS\Nexteer_Tool_Chain_Release\Release_XXJul2016\MFiles\Nexteer_Utilities v4.7.0\EA3_Library\FPM_u16_FloatToFixed_m.mexw64CF010A_GmTqArbn/GmTqArbn/GmTqArbnPer1/ESC logic/FPM_u16_FloatToFixed_m1
      CF010A_GmTqArbn/GmTqArbn/GmTqArbnPer1/ESC logic/FPM_u16_FloatToFixed_m2
      ...
    3C:\KVS\EPS\Nexteer_Tool_Chain_Release\Release_XXJul2016\MFiles\Nexteer_Utilities v4.7.0\EA3_Library\IntplVarXY_u16_u16Xu16Y_Cnt.mexw64CF010A_GmTqArbn/GmTqArbn/GmTqArbnPer1/PosnServo_Smoothed_Ramp/IntplVarXY_u16_u16Xu16Y_Cnt
      CF010A_GmTqArbn/GmTqArbn/GmTqArbnPer1/PosnServo_Smoothed_Ramp/IntplVarXY_u16_u16Xu16Y_Cnt1
      ...

    Consider setting Solver data inconsistency [?] to either error or warning (currently set to none) to validate whether S-functions adhere to the ODE solver consistency rules that Simulink applies to its built-in blocks.

    Consider setting ArrayBounds exceeded [?]to either error or warning (currently set to none) to check if S-functions are writing outside array boundaries.

    Note: These runtime diagnostics may slow down simulation considerably. You should set them back to none once you have verified that they do not cause any warnings or errors during simulation.


     Check if Read/Write diagnostics are enabled for Data Store blocks

    Note: These runtime diagnostics may slow down simulation considerably. You should set them back to Disable all once you have verified that they do not cause any warnings or errors during simulation.



            Simulink Model File Integrity