1 - SF020A_HwAgTrakgServo_Design_PeerReviewChkList

Nexteer_Template_V1.0

Overview

Peer Review Instructions
Technical Review Checklist
Template Change Log


Sheet 1: Peer Review Instructions

Instructions for Functional Design Package Peer Review




PRE-MEETING


Function OwnerConfirm that requirements are reviewed and approved PRIOR to the FDP peer review

Function OwnerStart with latest version of the template for any "first reviews" - Continue to use existing temmplate for re-reviews

Function OwnerProvide the functional design package (changed documents) to the invited attendees 1-2 working days in advance of review

Function OwnerNotify the assigned peer reviewer and make sure they are prepared to do their function in the meeting

Function OwnerIdentify necessary attendance and invite to meeting

Function OwnerComplete the "Author" column information for sections 1 through 5 prior to the review

Function OwnerComplete the attendance invitation list in section 7

Function OwnerFor Re-reviews only: Complete the column "remarks by author" to identify actions taken to address items found in earlier reviews.



DURING MEETING


Function OwnerPresent document changes to the review team

Peer ReviewerCapture attendance of the review

Peer ReviewerCapture actions and issues in section 6. Identify issue summary, Document type, Reference (Requirement ID, section number, etc), Defect Type and indicate status as "OPEN"



POST MEETING


Function OwnerFollow up on all "open" items. Update "Summary of Resolution" to indicate what was done or decided.

Function OwnerSchedule follow up review OR review open items with peer reviewer and obtain agreement to close

Peer ReviewerClose change request in system and confirm all associated tasks are complete. Upload peer review checklist (this document) with any FDP updates

Sheet 2: Technical Review Checklist

Technical Review Checklist - Template Version 02.02.00







Product NameElectric Power SteeringElectrical Arch.4Review ScopeDefect TypeNumbers




YesClosedFR
Function IDSF020A_HwAgTrakgServo

Err:509Requirement0




NoRejectedFDD
Long NameHandwheel Angle Tracking Servo

Interface0




NAOpenModel
Version that you started from. NOT the version you hope to release. If this will be v1.0.0, enter NA. Starting Baseline1.5.0EffortDesign0






FMEA
AuthorRangarajan RamanujamReview Effort(Hrs.)
Standards0






*.m File


Corr+Verf effort(Hrs.)
Documentation0






Cal Process


Total Effort (Hrs.)0.00Others0













Total0







Checklist No.Description of CheckAuthor: This column is for Self review. Author shall fill Yes/No/NA against each point in checklist. AuthorAuthor: This column is for reviewer. Reviewer shall fill Yes/No/NA against each point in checklist. ReviewerAuthor: Detailed Description of the finding shall be provided by the reviewer. Description of finding by reviewerAuthor: Defect type to be selected. Defect TypeAuthor: What action is taken to fix the comment & other remarks need to be filled by author. Remarks By AuthorAuthor: Data in this column shall be filled by reviewer after checking whether the rework is completed. Status







1Section 1: Data Dictionary














Is Filename of Data Dictionary in correct format?YesYes












Is the FDD.Version property correctly updated?YesYes












Is the Data Dictionary Verification report error free?NoNo

Name does not match required pattern. Name has been added to available signal list and is flagging an error due to function short name clashing with signal nameClosed








Does FDD Long Name, Short Name, and Description match requirements?YesYes












Are all runnables defined?YesYes












Do runnables have the correct time step?YesYes












Do server runnables correctly define arguments?YesYes












Are all clients defined?NANA












Do client definitions match the corresponding server runnable?NANA












Does name and metadata of every signal match its corresponding interface signal?NANA












Do output signal ranges match requirements (check DOOR min/max attributes too)?NANA












Are calibration tables named correctly (e.g. AssiX and AssiY)?YesYes












Are all data types represented by released Data_Management classes?YesYes












Do all calibrations have correct values for all metadata?YesYes












Is NVM defined in the appropriate number of blocks?NANA












Are constants defined with proper scope (local vs global)?YesYes












Are all dependent constants and calibrations included in one file?YesYes












Does FDD.DesignASIL match requirements?YesYes

The ASIL rating was obtained from discussion with the Safety Group.
























2Section 2: ModelAuthor: This column is for Self review. Author shall fill Yes/No/NA against each point in checklist. AuthorAuthor: This column is for reviewer. Reviewer shall fill Yes/No/NA against each point in checklist. ReviewerAuthor: Detailed Description of the finding shall be provided by the reviewer. Description of finding by reviewerAuthor: Defect type to be selected. Defect TypeAuthor: What action is taken to fix the comment & other remarks need to be filled by author. Remarks By AuthorAuthor: Data in this column shall be filled by reviewer after checking whether the rework is completed. Status








Is filename of model in correct format?YesYes












Is Top level of model annotated with Requirements Baseline?YesYes












Is the Top level of the model annotated with Tool Dependencies?YesYes












Is Top level of model annotated with Change Log or History?YesYes












Is the 2nd level of model free from subsystems that are not Function-Call Subsystems?YesYes












Is the 2nd level of model free from arithmetic and logic operations?YesYes












Are the Runnable trigger signals named as "call_<Runnable>"?YesYes












Does 2nd level of model have a properly updated annotation with name, description, and intended baseline number?YesYes












Are all data flow layers free of Function-Call Subsystems and Memory Store blocks?YesYes












Does the Model have the confidentiality and copyright information inside all its Subsystems?YesYes












Are all the Memory Store blocks for PIM and Display Variables located on the 2nd level of model?YesYes












Is each diagnostic (NTC) capable of being set to "PASS"?NANA












Does non-zero intialization of PIM occur in the function's Init runnable?NANA












Does design properly include Set Ram Block Status when NVM RAM values change?NANA












Does model include appropriate logic for dealing with missing or corrupted NVM data?NANA












Does model execute without errors/warnings after loading NxtrMBDConfig configuration set?YesYes



























3Section 3: Requirements LinkingAuthor: This column is for Self review. Author shall fill Yes/No/NA against each point in checklist. AuthorAuthor: This column is for reviewer. Reviewer shall fill Yes/No/NA against each point in checklist. ReviewerAuthor: Detailed Description of the finding shall be provided by the reviewer. Description of finding by reviewerAuthor: Defect type to be selected. Defect TypeAuthor: What action is taken to fix the comment & other remarks need to be filled by author. Remarks By AuthorAuthor: Data in this column shall be filled by reviewer after checking whether the rework is completed. Status








Are all requirements links of the format <FDDNumber>_<ObjectID>?YesYes












Does requirements HTML report reference only the DOORS module of this component for all links in the design?YesYes












Are linked blocks linked to the correct requirements(s)? (watch for problems due to copy/pasted blocks)YesYes












Is the list of unlinked blocks acceptable?YesYes



























4Section 4: Model AdvisorAuthor: This column is for Self review. Author shall fill Yes/No/NA against each point in checklist. AuthorAuthor: This column is for reviewer. Reviewer shall fill Yes/No/NA against each point in checklist. ReviewerAuthor: Detailed Description of the finding shall be provided by the reviewer. Description of finding by reviewerAuthor: Defect type to be selected. Defect TypeAuthor: What action is taken to fix the comment & other remarks need to be filled by author. Remarks By AuthorAuthor: Data in this column shall be filled by reviewer after checking whether the rework is completed. Status








Was Model Advisor run with the correct configuration settings?YesYes












Is the Model Advisor rerport free from "Fails".YesYes












Are Model Advisor report "Warnings" acceptable?YesYes



























5Section 5: Delivery PackageAuthor: This column is for Self review. Author shall fill Yes/No/NA against each point in checklist. AuthorAuthor: This column is for reviewer. Reviewer shall fill Yes/No/NA against each point in checklist. ReviewerAuthor: Detailed Description of the finding shall be provided by the reviewer. Description of finding by reviewerAuthor: Defect type to be selected. Defect TypeAuthor: What action is taken to fix the comment & other remarks need to be filled by author. Remarks By AuthorAuthor: Data in this column shall be filled by reviewer after checking whether the rework is completed. Status








Does Design folder contain only the model, data dictionary, and (optionally) a simulation setup script?YesYes












Does Doc folder contain a zipped HTML webview model?YesYes












Was webview model created without requirements highlighted?YesYes












Does Reports folder contain only the data dictionary verification report, Model Advisor report, and zipped requirements traceability report?YesYes



























4Section 6: Other Issus/Actions IdentifiedDocumentReferenceSummary of resolutionAuthor: Defect type to be selected. Defect TypeAuthor: What action is taken to fix the comment & other remarks need to be filled by author. Remarks By AuthorAuthor: Data in this column shall be filled by reviewer after checking whether the rework is completed. Status







4.1














4.2














4.3














4.4














4.5














4.6














4.7














4.8














4.9














4.10














4.11














4.12














4.13














4.14














4.15














4.16














4.17














4.18














4.19














4.20














4.21














4.22














4.23














4.24














4.25














5Section 7: APPROVALS













RoleFirst ReviewDateAttendanceApproval?










Function Owner*Rangarajan Ramanujam9/23/2016YesYes










Peer Reviewer*













Safety<Name - if invited>












Software<Name - if invited>












ESG / SystemsSneha SinghYesYes










EPDT / CSE<Name - if invited>












Hardware<Name - if invited>












Test<Name - if invited>












RoleSecond Review (if required)DateAttendanceApproval?










Function Owner*<Owner Name>













Peer Reviewer*<Name>












Safety<Name - if invited>












Software<Name - if invited>












ESG / Systems<Name - if invited>












EPDT / CSE<Name - if invited>












Hardware<Name - if invited>












Test<Name - if invited>












RoleThird Review (if required)DateAttendanceApproval?










Function Owner*<Owner Name>













Peer Reviewer*<Name>












Safety<Name - if invited>












Software<Name - if invited>












ESG / Systems<Name - if invited>












EPDT / CSE<Name - if invited>












Hardware<Name - if invited>












Test<Name - if invited>












RoleFourth Review (if required)DateAttendanceApproval?










Function Owner*<Owner Name>













Peer Reviewer*<Name>












Safety<Name - if invited>












Software<Name - if invited>












ESG / Systems<Name - if invited>












EPDT / CSE<Name - if invited>












Hardware<Name - if invited>












Test<Name - if invited>












RoleAdd more if necessaryDateAttendanceApproval?










































P.S.:Yes indicates adherence














No indicates non-adherence, reviewer shall provide suitable comments at the end of this document for each point.














NA indicates not applicable














Sheet 3: Template Change Log

RevChangeAuthor
01.00.05Added lesson learned #3.5MDK
01.00.06Added lesson learned #3.6, 3.7 - Structure and writing of NVM in mfiles and models.MDK
02.00.00Combined ESG and Systems into one, compatible with Data_Management 2.13.0 of CreateDD and VerifyDD.K. Derry
02.01.00Added: Does FDD.DesignASIL match requirements?
Added: Was webview model created without requirements highlighted?
Removed: Redundant row in Data Dictionary section.
Formatting: Column C now consistently center-justified.
K. Derry
02.02.00Added: Are all data types represented by released Data_Management classes?
Removed: Are all runnables defined? Rationale: Automated tools checking.
Removed: Does the Component shortname match data dictionary FDD metadata?
Removed: "Data store name must resolve to Simulink signal object"
Edited: Model Advisor report should now be left unzipped.
K. Derry











































































2 - SF020A_HwAgTrakgServo_ModelAdvisorReport

Model Advisor Report for 'SF020A_HwAgTrakgServo'
Model Advisor Report - SF020A_HwAgTrakgServo.slx
Simulink version: 8.2Model version: 1.78
System: SF020A_HwAgTrakgServoCurrent run: 09-Sep-2016 11:44:06
 Model Advisor configuration: ...NxtrModelAdvisorConfig.mat

Run Summary
PassFailWarningNot RunTotal
   54   0   13   133200


By Task

    Code Generation Efficiency


 Check optimization settings

You should turn on the following optimization(s):

  • Block reduction
  • Remove code from floating-point to integer conversions that wraps out-of-range values
  • Inline invariant signals
  • The Simulation range checking diagnostic is enabled. Because this diagnostic can increase the time it takes to simulate your model, you should consider turning it off, by setting its value to none.
  • Ignore testpoints when generating code
  • Pass reusable subsystem outputs as individual arguments



  •     Frequency Response Estimation


        Managing Data Store Memory Blocks


        Managing Library Links And Variants


        Model Referencing


        Modeling Guidelines for MISRA-C:2004


        Modeling Physical Systems


        Modeling Signals and Parameters using Buses


        Modeling Single-Precision Systems


        Modeling Standards for DO-178C/DO-331


        Modeling Standards for EN 50128


        Modeling Standards for IEC 61508


        Modeling Standards for ISO 26262


     Display model metrics and complexity report

    Display number of elements and name, level, and depth of subsystems for the model or subsystem

    Model metrics information
    Display number of elements for Simulink blocks and Stateflow constructs


    Summary

    Element TypeCount
    Inport133
    Outport77
    SubSystem96


    Simulink

    Block TypeCount
    Inport133
    SubSystem96
    Constant93
    Outport77
    S-Function38
    From36
    DataStoreWrite22
    Math20
    Sum19
    Goto19
    ActionPort17
    DataStoreMemory16
    Product16
    UnaryMinus13
    DataTypeConversion11
    Width11
    DataStoreRead9
    If8
    Merge8
    Ground5
    RelationalOperator3
    TriggerPort2
    Demux1
    Logic1
    Abs1
    Terminator1
    ∧ Less

    Model complexity information
    Display name, level, and depth of subsystems


    Maximum Subsystem Depth: 9

    Subsystem Depth

    Subsystem NameLevelDepth
    HwAgTrakgServo18
    HwAgTrakgServo/CopyRight221
    HwAgTrakgServo/HwAgTrakgServoInit122
    HwAgTrakgServo/HwAgTrakgServoInit1/CopyRight231
    HwAgTrakgServo/HwAgTrakgServoInit1/DftlTermLpFil31
    HwAgTrakgServo/HwAgTrakgServoInit1/HwAgLpFil31
    HwAgTrakgServo/HwAgTrakgServoInit1/HwTqLpFil31
    HwAgTrakgServo/HwAgTrakgServoPer127
    HwAgTrakgServo/HwAgTrakgServoPer1/FilterDesiredAngle33
    HwAgTrakgServo/HwAgTrakgServoPer1/FilterDesiredAngle/Active_&_Ramp_Complete41
    HwAgTrakgServo/HwAgTrakgServoPer1/FilterDesiredAngle/FilLpUpdOutp41
    HwAgTrakgServo/HwAgTrakgServoPer1/FilterDesiredAngle/FixdToFloat_f32_u1641
    HwAgTrakgServo/HwAgTrakgServoPer1/FilterDesiredAngle/FloatToFixd_u16_f3241
    HwAgTrakgServo/HwAgTrakgServoPer1/FilterDesiredAngle/LnrIntrpn_u16_u16VariXu16VariY41
    HwAgTrakgServo/HwAgTrakgServoPer1/FilterDesiredAngle/RateLimDyn_f3241
    HwAgTrakgServo/HwAgTrakgServoPer1/FilterDesiredAngle/Use_Existing_HwAg42
    HwAgTrakgServo/HwAgTrakgServoPer1/FilterDesiredAngle/Use_Existing_HwAg/CopyRight251
    HwAgTrakgServo/HwAgTrakgServoPer1/FilterDesiredAngle/Use_HwAgTar42
    HwAgTrakgServo/HwAgTrakgServoPer1/FilterDesiredAngle/Use_HwAgTar/CopyRight251
    HwAgTrakgServo/HwAgTrakgServoPer1/FilterDesiredAngle/~Active_&_Ramp_Complete41
    HwAgTrakgServo/HwAgTrakgServoPer1/FilterDesiredAngle/~Active_&_~Ramp_Complete41
    HwAgTrakgServo/HwAgTrakgServoPer1/Output_Torque32
    HwAgTrakgServo/HwAgTrakgServoPer1/Output_Torque/BilnrIntrpnWithRound_u16_u16CmnXu16MplY41
    HwAgTrakgServo/HwAgTrakgServoPer1/Output_Torque/FixdToFloat_f32_u141
    HwAgTrakgServo/HwAgTrakgServoPer1/Output_Torque/FixdToFloat_f32_u1641
    HwAgTrakgServo/HwAgTrakgServoPer1/Output_Torque/FloatToFixd_u16_f141
    HwAgTrakgServo/HwAgTrakgServoPer1/Output_Torque/FloatToFixd_u16_f241
    HwAgTrakgServo/HwAgTrakgServoPer1/Output_Torque/FloatToFixd_u16_f3241
    HwAgTrakgServo/HwAgTrakgServoPer1/Output_Torque/LimDyn_f141
    HwAgTrakgServo/HwAgTrakgServoPer1/Output_Torque/LimDyn_f3241
    HwAgTrakgServo/HwAgTrakgServoPer1/Output_Torque/LnrIntrpn_u16_u16VariXu16VariY41
    HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control36
    HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/Compare To Constant41
    HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/Compare To Zero41
    HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID45
    HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/D-Term53
    HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/D-Term/FilLpUpdOutp61
    HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/D-Term/FixdToFloat_f32_u1661
    HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/D-Term/LimStat_f3261
    HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/D-Term/LnrIntrpn_u16_u16VariXu16VariY61
    HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/D-Term/No_162
    HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/D-Term/No_1/CopyRight271
    HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/D-Term/No_262
    HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/D-Term/No_2/CopyRight271
    HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/FloatToFixd_u16_f151
    HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/I-Term54
    HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/I-Term/FixdToFloat_f32_u161
    HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/I-Term/FixdToFloat_f32_u1661
    HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/I-Term/I-Anti Windup (state)62
    HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/I-Term/I-Anti Windup (state)/Ki=071
    HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/I-Term/I-Anti Windup (state)/Ki~=071
    HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/I-Term/LimDyn_f3261
    HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/I-Term/LnrIntrpn_u16_u16VariXu16VariY61
    HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/I-Term/LnrIntrpn_u16_u16VariXu16VariY161
    HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/I-Term/Reset63
    HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/I-Term/Reset/Send_Signal72
    HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/I-Term/Reset/Send_Signal/CopyRight281
    HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/I-Term/Reset/Send_Zero72
    HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/I-Term/Reset/Send_Zero/CopyRight281
    HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/LimDyn_f3251
    HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/P-Term52
    HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/P-Term/BilnrIntrpnWithRound_u16_u16CmnXu16MplY61
    HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/P-Term/FixdToFloat_f32_u161
    HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/P-Term/FloatToFixd_u16_f261
    HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/Reset53
    HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/Reset/Send_Signal62
    HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/Reset/Send_Signal/CopyRight271
    HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/Reset/Send_Zero62
    HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/Reset/Send_Zero/CopyRight271
    HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/Reset153
    HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/Reset1/Send_Signal62
    HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/Reset1/Send_Signal/CopyRight271
    HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/Reset1/Send_Zero62
    HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/Reset1/Send_Zero/CopyRight271
    HwAgTrakgServo/HwAgTrakgServoPer1/Transition_Control33
    HwAgTrakgServo/HwAgTrakgServoPer1/Transition_Control/Disabling_Mech42
    HwAgTrakgServo/HwAgTrakgServoPer1/Transition_Control/Disabling_Mech/CopyRight251
    HwAgTrakgServo/HwAgTrakgServoPer1/Transition_Control/Disabling_Mech/FilLpUpdOutp51
    HwAgTrakgServo/HwAgTrakgServoPer1/Transition_Control/Disabling_Mech/FixdToFloat_f32_u1651
    HwAgTrakgServo/HwAgTrakgServoPer1/Transition_Control/Disabling_Mech/FloatToFixd_u16_f3251
    HwAgTrakgServo/HwAgTrakgServoPer1/Transition_Control/Disabling_Mech/LnrIntrpn_u16_u16VariXu16VariY51
    HwAgTrakgServo/HwAgTrakgServoPer1/Transition_Control/Enable_Mech42
    HwAgTrakgServo/HwAgTrakgServoPer1/Transition_Control/Enable_Mech/CopyRight251
    HwAgTrakgServo/HwAgTrakgServoPer1/Transition_Control/FixdToFloat_f32_u1641
    HwAgTrakgServo/HwAgTrakgServoPer1/Transition_Control/FloatToFixd_u16_f3241
    HwAgTrakgServo/HwAgTrakgServoPer1/Transition_Control/LimStat_f3241
    HwAgTrakgServo/HwAgTrakgServoPer1/Transition_Control/LnrIntrpn_u16_u16VariXu16VariY41
    ∧ Less



     Check for model objects that do not link to requirements

    Check Simulink blocks and Stateflow objects that do not link to a requirements document

    Warning
    The following blocks do not link to a requirement document:

    ∧ Less
    Recommended Action
    For each object in the list, in the Model Editor, right-click the block, select Requirements, and specify a requirement.



        Modeling Standards for MAAB

            Naming Conventions


     Check subsystem names

    Identify subsystem names that use characters that are not correct in C code.

    See Also

    Warning
    The following subsystem names contain incorrect characters:

    ErrorSubsystem block
    Name contains incorrect characters...../Active_&_Ramp_Complete
    Name contains incorrect characters...../~Active_&_Ramp_Complete
    Name contains incorrect characters...../~Active_&_~Ramp_Complete
    Name contains incorrect characters...../PID/I-Term/I-Anti Windup (state)/Ki=0
    Name contains incorrect characters...../PID/I-Term/I-Anti Windup (state)/Ki~=0


    Recommended Action
    Rename the subsystem blocks using correct characters.


     Check character usage in block names

    Identify block names that use characters that are not correct in C code.

    See Also

    Warning
    The following block names use characters that are not correct for C code:

    Error typeBlock
    Name starts with a space (" ").SF020A_HwAgTrakgServo/HwAgTrakgServo/
    Name starts with a space (" ").SF020A_HwAgTrakgServo/HwAgTrakgServo/
    Name starts with a space (" ").SF020A_HwAgTrakgServo/HwAgTrakgServo/
    Name starts with a space (" ")...../HwAgTrakgServo/
    Name starts with a space (" ")...../HwAgTrakgServo/
    Name starts with a space (" ")...../HwAgTrakgServo/
    Name starts with a space (" ")...../HwAgTrakgServo/
    Name starts with a space (" ")...../HwAgTrakgServo/
    Name starts with a space (" ")...../HwAgTrakgServo/
    Name starts with a space (" ")...../
    Name starts with a space (" ").....
    Name starts with a space (" ")...../HwAgTrakgServoPer1/
    Name starts with a space (" ")...../HwAgTrakgServoPer1/
    Name starts with a space (" ")...../HwAgTrakgServoPer1/
    Name starts with a space (" ")...../
    Name starts with a space (" ")...../
    Name starts with a space (" ")...../HwAgTrakgServoPer1/FilterDesiredAngle/
    Name starts with a space (" ")...../FilterDesiredAngle/
    Name starts with a space (" ")...../FilterDesiredAngle/
    Name starts with a space (" ")...../HwAgTrakgServoPer1/Output_Torque/
    Name starts with a space (" ")...../HwAgTrakgServoPer1/PID_Control/PID/
    Name starts with a space (" ")...../PID/
    Name starts with a space (" ")...../PID/
    Name starts with a space (" ")...../PID/
    Name starts with a space (" ")...../PID_Control/PID/D-Term/
    Name starts with a space (" ")...../PID_Control/PID/D-Term/
    Name starts with a space (" ")...../PID_Control/PID/I-Term/
    Name starts with a space (" ")...../PID_Control/PID/I-Term/
    Name starts with a space (" ")...../PID/I-Term/
    Name starts with a space (" ")...../Transition_Control/
    Name starts with a space (" ")...../Transition_Control/Disabling_Mech/
    Name starts with a space (" ")...../Transition_Control/Enable_Mech/
    ∧ Less


    Recommended Action
    Rename the block using correct characters.



            Model Architecture


     Check for mixing basic blocks and subsystems

    Identify levels in the model that include basic blocks and subsystems. Each level of a model must be designed with blocks of the same level (for example, only subsystems or only basic blocks).

    See Also

    Warning
    The following level(s) in the model include basic blocks and subsystems:

    SystemBlock path
    SF020A_HwAgTrakgServo/HwAgTrakgServo..../HwAgTrakgServo/CopyRight2
    ..../HwAgTrakgServo/HwAgTrakgServoPer1..../HwAgTrakgServoPer1/
    ..../HwAgTrakgServo/HwAgTrakgServoPer1..../HwAgTrakgServoPer1/
    ..../HwAgTrakgServo/HwAgTrakgServoPer1..../HwAgTrakgServoPer1/
    ..../HwAgTrakgServo/HwAgTrakgServoPer1..../
    ..../HwAgTrakgServo/HwAgTrakgServoPer1..../
    ..../HwAgTrakgServoPer1/FilterDesiredAngle..../HwAgTrakgServoPer1/FilterDesiredAngle/
    ..../HwAgTrakgServoPer1/FilterDesiredAngle..../FilterDesiredAngle/
    ..../HwAgTrakgServoPer1/FilterDesiredAngle..../FilterDesiredAngle/
    ..../HwAgTrakgServoPer1/FilterDesiredAngle..../FilterDesiredAngle/FilLpUpdOutp
    ..../HwAgTrakgServoPer1/FilterDesiredAngle..../FilterDesiredAngle/FixdToFloat_f32_u16
    ..../HwAgTrakgServoPer1/FilterDesiredAngle..../FilterDesiredAngle/FloatToFixd_u16_f32
    ..../HwAgTrakgServoPer1/FilterDesiredAngle..../LnrIntrpn_u16_u16VariXu16VariY
    ..../HwAgTrakgServoPer1/FilterDesiredAngle..../FilterDesiredAngle/RateLimDyn_f32
    ..../HwAgTrakgServoPer1/PID_Control..../PID_Control/Compare To Constant
    ..../HwAgTrakgServoPer1/PID_Control..../PID_Control/Compare To Zero
    ..../HwAgTrakgServoPer1/PID_Control..../PID_Control/Logical Operator
    ..../HwAgTrakgServoPer1/PID_Control..../HwAgTrakgServoPer1/PID_Control/Sum
    ..../HwAgTrakgServoPer1/PID_Control/PID..../HwAgTrakgServoPer1/PID_Control/PID/
    ..../HwAgTrakgServoPer1/PID_Control/PID..../PID/
    ..../HwAgTrakgServoPer1/PID_Control/PID..../PID/
    ..../HwAgTrakgServoPer1/PID_Control/PID..../PID/
    ..../HwAgTrakgServoPer1/PID_Control/PID..../PID_Control/PID/Constant1
    ..../HwAgTrakgServoPer1/PID_Control/PID..../PID_Control/PID/FloatToFixd_u16_f1
    ..../HwAgTrakgServoPer1/PID_Control/PID..../PID_Control/PID/LimDyn_f32
    ..../HwAgTrakgServoPer1/PID_Control/PID..../HwAgTrakgServoPer1/PID_Control/PID/Sum
    ..../PID_Control/PID/D-Term..../PID_Control/PID/D-Term/
    ..../PID_Control/PID/D-Term..../PID_Control/PID/D-Term/
    ..../PID_Control/PID/D-Term..../PID_Control/PID/D-Term/Constant1
    ..../PID_Control/PID/D-Term..../PID_Control/PID/D-Term/FilLpUpdOutp
    ..../PID_Control/PID/D-Term..../PID/D-Term/FixdToFloat_f32_u16
    ..../PID_Control/PID/D-Term..../PID_Control/PID/D-Term/LimStat_f32
    ..../PID_Control/PID/D-Term..../D-Term/LnrIntrpn_u16_u16VariXu16VariY
    ..../PID_Control/PID/D-Term..../PID_Control/PID/D-Term/Product
    ..../PID_Control/PID/D-Term..../PID_Control/PID/D-Term/Sum1
    ..../PID_Control/PID/I-Term..../PID_Control/PID/I-Term/
    ..../PID_Control/PID/I-Term..../PID_Control/PID/I-Term/
    ..../PID_Control/PID/I-Term..../PID/I-Term/
    ..../PID_Control/PID/I-Term..../PID_Control/PID/I-Term/Constant1
    ..../PID_Control/PID/I-Term..../PID/I-Term/FixdToFloat_f32_u1
    ..../PID_Control/PID/I-Term..../PID/I-Term/FixdToFloat_f32_u16
    ..../PID_Control/PID/I-Term..../PID_Control/PID/I-Term/LimDyn_f32
    ..../PID_Control/PID/I-Term..../I-Term/LnrIntrpn_u16_u16VariXu16VariY
    ..../PID_Control/PID/I-Term..../I-Term/LnrIntrpn_u16_u16VariXu16VariY1
    ..../PID_Control/PID/I-Term..../PID_Control/PID/I-Term/Product
    ..../PID_Control/PID/I-Term..../PID_Control/PID/I-Term/Sum
    ..../HwAgTrakgServoPer1/Transition_Control..../Transition_Control/
    ..../HwAgTrakgServoPer1/Transition_Control..../Transition_Control/Constant1
    ..../HwAgTrakgServoPer1/Transition_Control..../Transition_Control/Constant6
    ..../HwAgTrakgServoPer1/Transition_Control..../Transition_Control/FixdToFloat_f32_u16
    ..../HwAgTrakgServoPer1/Transition_Control..../Transition_Control/FloatToFixd_u16_f32
    ..../HwAgTrakgServoPer1/Transition_Control..../Transition_Control/LimStat_f32
    ..../HwAgTrakgServoPer1/Transition_Control..../LnrIntrpn_u16_u16VariXu16VariY
    ..../HwAgTrakgServoPer1/Transition_Control..../Transition_Control/Relational Operator
    ..../HwAgTrakgServoPer1/Transition_Control..../Transition_Control/Sum4
    ∧ Less


    Recommended Action
    If possible, replace blocks at the identified level of the model hierarchy with basic blocks. Move nonvirtual blocks into the identified subsystem.



            Model Configuration Options

            Simulink


     Check for Simulink diagrams using nonstandard display attributes

    Identify nonstandard display attributes in Simulink diagrams.

    See Also

    _________________________________________________________________________________________

    Check format settings
    Identify incorrect model-level format options.

    Passed
    The format options are correct.
    _________________________________________________________________________________________

    Check block colors
    Identify blocks using nonstandard colors.

    Warning
    The following blocks use nonstandard colors:

    ∧ Less
    Recommended Action
    Set the block foreground color to black and the background color to white.
    _________________________________________________________________________________________

    Check canvas colors
    Identify canvases that are not white.

    Passed
    All diagrams use a white canvas.
    _________________________________________________________________________________________

    Check diagram zoom
    Identify diagrams that do not have zoom factor set to 100 %.

    Warning
    The following diagrams do not have zoom factor set to 100 percent:

    ∧ Less
    Recommended Action
    For each listed diagram, select View > Zoom > Normal View (100%).


     Check font formatting

    Identify inconsistent formatting of text.

    See Also

    Warning
    Font formatting is not consistent.

    The following font characteristics are used in the model/subsystem. Font characteristics are sorted by number of occurrences. The most common characteristics are bold.
    Font NameFont SizeFont Style

    Helvetica

    10
    14
    9

    normal



    Recommended Action
    To have consistent font formatting, click Modify All Fonts to apply the font formatting selected in the input parameters above to all objects.

    Input Parameters Selection
    NameValue
    Font NameCommon
    Font SizeCommon
    Font StyleCommon


     Check positioning and configuration of ports

    Identify input and output ports with incorrect positioning and configurations.

    See Also

    _________________________________________________________________________________________

    Check Inport blocks position
    Identify Inport blocks that result in left-flowing signals.

    Warning
    The following Inport blocks are too far to the right, resulting in left-flowing signals:

    Recommended Action
    Move the Inport blocks to the left of the sink block.
    _________________________________________________________________________________________

    Check Outport block position
    Identify Outport blocks that result in left-flowing signals.

    Passed
    There are no Outport blocks in the model that result in left-flowing signals.
    _________________________________________________________________________________________

    Check port orientation
    Identify port blocks with nondefault orientation.

    Warning
    The following ports do not have the default orientation:

    Recommended Action
    Rotate the block to the default orientation. Multiple rotations might be required.
    _________________________________________________________________________________________

    Check for duplicate Inports blocks
    Identify duplicate Inport blocks.

    Passed
    All Inport blocks in the model are used once.


     Check visibility of block port names

    Identify port block names that are not uniformly displayed. The block names must all be displayed or none displayed. Library blocks are an exception to this rule. This check ignores masked and subsystem blocks.

    See Also

    _________________________________________________________________________________________

    Check for incorrect port name display
    Identify ports that are incorrectly displaying names.

    Passed
    Subsystem blocks are correctly displayed.
    _________________________________________________________________________________________

    Check for incorrect subsystem port name display
    Identify subsystems that are incorrectly displaying names.

    Passed
    Subsystem blocks are correctly displayed.

    Input Parameters Selection
    NameValue
    Display all port names (Diagram > Format > Show Block Name).true


     Check the display attributes of block names

    Identify whether to display block names.

    See Also

    _________________________________________________________________________________________

    Check for blocks with hidden names and obvious function
    Identify block names that are displayed but can be hidden due to obvious behavior.

    Passed
    All blocks with obvious behavior have hidden names.
    _________________________________________________________________________________________

    Check for non-descriptive displayed block names
    Identify block names that are displayed but should be hidden due to a lack of a descriptive name.

    Warning
    The following blocks have a name displayed, however, the name is not descriptive:

    ∧ Less
    Recommended Action
    Modify the block name to provide descriptive information, or hide the block name by deselecting (Diagram > Format > Show Block Name).
    _________________________________________________________________________________________

    Check for missing block names
    Identify block names that are hidden but should be displayed to show a descriptive name.

    Warning
    The following blocks have descriptive names, however, the names are hidden:

    Recommended Action
    Modify the blocks to show the block name (Diagram > Format > Show Block Name).


     Check signal line labels

    Identify blocks that require labeled signals. A subset of source and destination blocks require labeled signals.

    See Also

    _________________________________________________________________________________________

    Check source block labels
    The following source blocks require labeled signals; Inport, From, Data Store Read, Constant, Bus Selector, Demux, Selector. If the signal name is visible on the block, this rule is considered met.

    Warning
    The following signals have no label:

    ∧ Less
    Recommended Action
    Add a new or propagated label to the signal line.
    _________________________________________________________________________________________

    Check destination block labels
    The following destination blocks require labeled signals; Outport, Goto, Data Store Write, Bus Creator, Mux, Subsystem, Chart. If the signal name is visible on the source block, this rule is considered met.

    Warning
    The following signals have no label:

    ∧ Less
    Recommended Action
    Add a new or propagated label to the signal line.


     Check for propagated signal labels

    Identify propagated labels on signal lines.

    See Also

    _________________________________________________________________________________________

    Check subsystem input labels
    Identify subsystem inputs that are labeled and display propagated signals.

    Passed
    All inputs to the subsystem have labels and display propagated signals.
    _________________________________________________________________________________________

    Check subsystem output labels
    Identify outputs from subsystems that are labeled and display signal propagation.

    Passed
    All outputs from the subsystem have labels and display propagated signals.
    _________________________________________________________________________________________

    Signal propagation for nonsubsystem blocks
    Identify the signal propagation status for both transformative and nontransformative blocks.

    Passed
    All outputs from non subsystem blocks correctly use labels and display propagated signals.



            Stateflow


     Check usage of exclusive and default states in state machines

    Identify Stateflow charts and substates that incorrectly use or define exclusive and default states.
    Note: This check does not support charts that use MATLAB as the action language.

    See Also

    _________________________________________________________________________________________

    Check Stateflow charts for exclusive states
    Identify Stateflow charts that have singular exclusive (OR) states.

    Passed
    The Stateflow charts do not have singular exclusive (OR) states.
    _________________________________________________________________________________________

    Check Stateflow charts for undefined default states
    Identify Stateflow charts that do not define default states.

    Passed
    Each Stateflow chart defines a default state.
    _________________________________________________________________________________________

    Check for multiple states assigned as the default state
    At the root level in the Stateflow hierarchy only one state should be assigned as the default.

    Passed
    The root level of the chart has only one default state assigned.
    _________________________________________________________________________________________

    Check for substates with singular OR states
    States configured as OR should always be part of a group of states.

    Passed
    No singular OR states were detected.
    _________________________________________________________________________________________

    Check for substates without default states defined
    At every level in the Stateflow hierarchy a default state should be assigned.

    Passed
    All substates have default states assigned.
    _________________________________________________________________________________________

    Check for substates with multiple default states defined
    At every level in the Stateflow hierarchy only one state should be assigned as the default.

    Passed
    All levels of the chart have only one default state assigned.


     Check transition orientations in flowcharts

    Identify transitions in Stateflow flowcharts that are drawn incorrectly.

    See Also

    _________________________________________________________________________________________

    Check for conditions drawn vertically
    Condition expressions should be drawn on the horizontal segments of flowcharts.

    Passed
    All conditions expressions were drawn horizontally.
    _________________________________________________________________________________________

    Check for action transitions drawn vertically
    Transition actions should be drawn on the vertical segments of flowcharts.

    Passed
    All transitions actions where drawn vertically.
    _________________________________________________________________________________________

    Check for junctions for default transitions
    All Junctions in a flow chart should have a default exit transition.

    Passed
    All Junctions have a default exit transition.
    _________________________________________________________________________________________

    Check for transitions that combine condition and action
    Flowcharts should not combine condition evaluations and action expressions in a single transition.

    Passed
    No combined expressions where found in the chart.



            MATLAB Functions


        Requirements Consistency Checking


     Identify selection-based links having description fields that do not match their requirements document text

    Inconsistencies:

    The following selection-based links have descriptions that differ from their corresponding selections in the requirements documents. If this reflects a change in the requirements document, click Update to replace the current description in the selection-based link with the text from the requirements document (the external description).
     
    Block 

    Current description External description  

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoEna

    REQ:SF020A_9REQ: SF020A_9

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/VehSpd

    REQ:SF020A_32REQ: SF020A_32

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoCmd

    REQ:SF020A_33REQ: SF020A_33

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAg

    REQ:SF020A_34REQ: SF020A_34

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwTq

    REQ:SF020A_35REQ: SF020A_35

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/MotVelCrf

    REQ:SF020A_36REQ: SF020A_36

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/MotTqServoCmd

    REQ:SF020A_11REQ: SF020A_11

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/FilterDesiredAngle/HWA_Target

    REQ:SF020A_99REQ: SF020A_99

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/FilterDesiredAngle/VehSpd_kph

    REQ:SF020A_99REQ: SF020A_99

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/FilterDesiredAngle/

    REQ:SF020A_99REQ: SF020A_99

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/FilterDesiredAngle/

    REQ:SF020A_101REQ: SF020A_101

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/FilterDesiredAngle/Active_&_Ramp_Complete

    REQ:SF020A_99REQ: SF020A_99

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/FilterDesiredAngle/From7

    REQ:SF020A_100REQ: SF020A_100

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/FilterDesiredAngle/Use_HwAgTar

    REQ:SF020A_99REQ: SF020A_99

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/FilterDesiredAngle/~Active_&_Ramp_Complete

    REQ:SF020A_100REQ: SF020A_100

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/FilterDesiredAngle/~Active_&_~Ramp_Complete

    REQ:SF020A_101REQ: SF020A_101

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/FilterDesiredAngle/HWA_Target_Filt

    REQ:SF020A_98REQ: SF020A_98

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/Output_Torque/VehSpd

    REQ:SF020A_127REQ: SF020A_127

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/Output_Torque/SmoothEnable

    REQ:SF020A_127REQ: SF020A_127

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/Output_Torque/PID_Cmd

    REQ:SF020A_127REQ: SF020A_127

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/Output_Torque/MtrVel_MtrNmpRadpS

    REQ:SF020A_127REQ: SF020A_127

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/Output_Torque/

    REQ:SF020A_128REQ: SF020A_128

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/Output_Torque/From

    REQ:SF020A_128REQ: SF020A_128

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/Output_Torque/From1

    REQ:SF020A_128REQ: SF020A_128

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/Output_Torque/Goto

    REQ:SF020A_128REQ: SF020A_128

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/Output_Torque/Product

    REQ:SF020A_127REQ: SF020A_127

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/Output_Torque/Product1

    REQ:SF020A_127REQ: SF020A_127

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/Output_Torque/Sum1

    REQ:SF020A_127REQ: SF020A_127

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/Output_Torque/MotTqServoCmd

    REQ:SF020A_126REQ: SF020A_126

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/HWA_Target_Filt

    REQ:SF020A_102REQ: SF020A_102

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/HWA_HwDeg

    REQ:SF020A_102REQ: SF020A_102

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/bActive

    REQ:SF020A_103REQ: SF020A_103

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/bRampComplete

    REQ:SF020A_103REQ: SF020A_103

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/Goto2

    REQ:SF020A_103REQ: SF020A_103

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/Logical Operator

    REQ:SF020A_103REQ: SF020A_103

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/Sum

    REQ:SF020A_102REQ: SF020A_102

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/Transition_Control/Constant1

    REQ:SF020A_95REQ: SF020A_95

    Update
    REQ:SF020A_96REQ: SF020A_96

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/Transition_Control/Relational Operator

    REQ:SF020A_95REQ: SF020A_95

    Update
    REQ:SF020A_96REQ: SF020A_96

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/Transition_Control/SmoothEnable

    REQ:SF020A_69REQ: SF020A_69

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/Transition_Control/bRampComplete

    REQ:SF020A_94REQ: SF020A_94

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/Error

    REQ:SF020A_104REQ: SF020A_104

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/

    REQ:SF020A_124REQ: SF020A_124

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/Constant1

    REQ:SF020A_124REQ: SF020A_124

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/From8

    REQ:SF020A_125REQ: SF020A_125

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/From9

    REQ:SF020A_104REQ: SF020A_104

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/Goto1

    REQ:SF020A_104REQ: SF020A_104

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/Reset

    REQ:SF020A_104REQ: SF020A_104

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/Reset1

    REQ:SF020A_125REQ: SF020A_125

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/Sum

    REQ:SF020A_123REQ: SF020A_123

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/Transition_Control/Disabling_Mech/

    REQ:SF020A_93REQ: SF020A_93

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/Transition_Control/Disabling_Mech/Abs

    REQ:SF020A_93REQ: SF020A_93

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/Transition_Control/Disabling_Mech/Constant5

    REQ:SF020A_93REQ: SF020A_93

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/Transition_Control/Disabling_Mech/Product3

    REQ:SF020A_93REQ: SF020A_93

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/Transition_Control/Disabling_Mech/Sum3

    REQ:SF020A_93REQ: SF020A_93

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/Transition_Control/Enable_Mech/

    REQ:SF020A_71REQ: SF020A_71

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/Transition_Control/Enable_Mech/Constant3

    REQ:SF020A_71REQ: SF020A_71

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/Transition_Control/Enable_Mech/Constant4

    REQ:SF020A_71REQ: SF020A_71

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/Transition_Control/Enable_Mech/Product2

    REQ:SF020A_71REQ: SF020A_71

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/Transition_Control/Enable_Mech/Sum2

    REQ:SF020A_71REQ: SF020A_71

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/Transition_Control/Enable_Mech/SmotngEna

    REQ:SF020A_71REQ: SF020A_71

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/D-Term/VehSpd

    REQ:SF020A_120REQ: SF020A_120

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/D-Term/

    REQ:SF020A_120REQ: SF020A_120

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/D-Term/

    REQ:SF020A_121REQ: SF020A_121

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/D-Term/Constant1

    REQ:SF020A_120REQ: SF020A_120

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/D-Term/If

    REQ:SF020A_121REQ: SF020A_121

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/D-Term/Merge

    REQ:SF020A_121REQ: SF020A_121

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/D-Term/No_1

    REQ:SF020A_121REQ: SF020A_121

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/D-Term/No_2

    REQ:SF020A_121REQ: SF020A_121

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/D-Term/Product

    REQ:SF020A_120REQ: SF020A_120

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/D-Term/Sum1

    REQ:SF020A_120REQ: SF020A_120

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/I-Term/bReset

    REQ:SF020A_118REQ: SF020A_118

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/I-Term/

    REQ:SF020A_117REQ: SF020A_117

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/I-Term/

    REQ:SF020A_116REQ: SF020A_116

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/I-Term/

    REQ:SF020A_118REQ: SF020A_118

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/I-Term/Constant1

    REQ:SF020A_116REQ: SF020A_116

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/I-Term/From1

    REQ:SF020A_117REQ: SF020A_117

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/I-Term/From2

    REQ:SF020A_117REQ: SF020A_117

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/I-Term/From3

    REQ:SF020A_117REQ: SF020A_117

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/I-Term/From4

    REQ:SF020A_117REQ: SF020A_117

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/I-Term/Goto1

    REQ:SF020A_117REQ: SF020A_117

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/I-Term/Goto2

    REQ:SF020A_116REQ: SF020A_116

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/I-Term/Goto3

    REQ:SF020A_116REQ: SF020A_116

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/I-Term/I-Anti Windup (state)

    REQ:SF020A_117REQ: SF020A_117

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/I-Term/Product

    REQ:SF020A_116REQ: SF020A_116

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/I-Term/Reset

    REQ:SF020A_118REQ: SF020A_118

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/I-Term/Sum

    REQ:SF020A_116REQ: SF020A_116

    Update

    SF020A_HwAgTrakgServo/HwAgTrakgServo/HwAgTrakgServoPer1/PID_Control/PID/P-Term/Product

    REQ:SF020A_112REQ: SF020A_112

    Update


        Simulation Accuracy


        Simulation Runtime Accuracy Diagnostics


        Simulink Model File Integrity


        Upgrading to the Current Simulink Version