TechnicalReference_CANdescs
Technical Reference CANdesc
CANdesc
Technical Reference
Version 3.09.00
Authors
Oliver Garnatz, Mishel Shishmanyan, Stefan Hübner,
Matthias Heil, Katrin Thurow, Patrick Rieder, Amr
Elazhary
Status
Released
2015, Vector Informatik GmbH
Version: 3.09.00
1 / 158
based on template version 5.1.0
Technical Reference CANdesc
1 History Author Date Version Remarks Oliver Garnatz
2003-11-12
2.00.00
Splitting into separate documents and
general revision
Oliver Garnatz
2004-01-13 2.00.01
Added chapter ‘Application interface flow’
Updated format template
Mishel Shishmanyan 2004-03-09 2.01.00
New application callback convention (from
CANdesc 2.09.00)
Mishel Shishmanyan 2004-03-29 2.02.00
New APIs:
DescGetActivityState (from CANdesc
2.10.00)
DescSchedulerTask() (from CANdesc
2.09.00)
Mishel Shishmanyan 2004-04-26 2.03.00
Added more information and limitations
about the ring-buffer mechanism
(12.6.9
“Ring Buffer Mechanism”) New feature:
Support for generic user service (from
CANdesc 2.11.00)
Force CANdesc to send RCR-RP
response (from CANdesc 2.11.00)
Stefan Hübner
2004-07-16 2.03.01
Editorial revision
Oliver Garnatz
2004-08-12 2.04.00
Added chapter 4.2 ReadDataByIdentifier
(SID $22) within the Single- and the Multiple
PID mode is described
Oliver Garnatz
2004-10-08 2.05.00
ESCAN0000982: Description of MainHandler
structure is not readable
ROE transmission unit is described in detail
Stefan Hübner
2004-10-15 2.06.00
Some additional information are provided
Oliver Garnatz
Peter Herrmann
2005-06-22 2.07.00
Added: Service $2C description.
Klaus Emmert
Added: Warning Text added
Mishel Shishmanyan 2005-08.03 2.08.00
API added: Oliver Garnatz
DescStateTask,
DescTimerTask,
DescMayCallStateTaskAgain.
ApplDescFatalError
API modified: DescTask,
ApplDescCheckSessionTransition,
DescGetActivityState,
DescGetStateSession.
API removed: 2015, Vector Informatik GmbH
Version: 3.09.00
2 / 158
based on template version 5.1.0
Technical Reference CANdesc
DescSchedulerTask
Modified description for
ReadDataByIdentifier with long data and
negative response in main-handler.
Oliver Garnatz
2006-03-02 2.09.00
Added: ...prevent the ECU going to sleep
while diagnostic is active
Mishel Shishmanyan 2006-03-24 2.10.00
Added: document overview
Mishel Shishmanyan 2006-04-27 2.11.00
Modified: -12.6.13 DynamicallyDefineDataIdentifier
($2C) (UDS) functions
-12.6.13.1 DescMayCallStateTaskAgain()
Mishel Shishmanyan 2007-02-22 2.12.00
Added: -
12.6.9.3 “DescRingBufferCancel()”
Matthias Heil
2008-01-03 2.13.00
Added:
Caution concerning user main
handler on protocol level l
Matthias Heil
2008-02-29 2.14.00
Added:
Handling of read/write memory by address:
-
9.5 “Read/Write Memory by Address”
- 12.6.8.2
“DescStartMemByAddrRepeatedCall()”
- 12.6.14 ”Memory Access Callbacks” Mishel Shishmanyan 2008-06-06 2.15.00
Removed:
Chapter “ResponseOnEvent Transmission
Unit”
Added:
- 12.6.13.3 “Non-volatile memory support” Mishel Shishmanyan 2008-11-09
2.16.00
Modified:
-
12.6.9 and 12.6.9.1: Added limitation for
UDS and SPRMIB with the ring buffer usage.
-
13.6 …work with the ring-buffer mechanism
Added:
- 12.6.15 Flash Boot Loader Support
- 13.8 …send a positive response without
request after FBL flash job Mishel Shishmanyan 2009-05-18 2.17.00
Modified:
12.6.6.1ApplDescCheckSessionTransition()
Added:
12.6.6.3DescIsSuppressPosResBitSet () Mishel Shishmanyan 2009-08-11
2.18.00
Modified:
Minor editorial changes
5.2 Configure Handlers using
CANdela attributes – added new
data object attributes 2015, Vector Informatik GmbH
Version: 3.09.00
3 / 158
based on template version 5.1.0
Technical Reference CANdesc
Added:
13.9 …enforce CANdesc to use ANSI C
instead of hardware optimized bit type
5.1 Configure DBC attributes for diagnostics
Mishel Shishmanyan 2009-09-17 3.00.00
Added:
6 CANdesc Configuration in GENy
8 Multi Identity
12.6.2 Multi Variant Configuration Functions Mishel Shishmanyan 2010-01-26 3.01.00
Added:
7 CANdescBasic Configuration in GENy Mishel Shishmanyan 2010-12-21 3.02.00
Modified:
12.6.14.1
ApplDescReadMemoryByAddress()
12.6.14.2
ApplDescWriteMemoryByAddress()
12.6.9.2 DescRingBufferWrite() Katrin Thurow
2011-08-25
3.03.00
Added:
8.1 Single Identity Mode
8.3 Multi Identity Mode
13.10 …configure Extended Addressing
13.11 …use Multiple Addressing
12.6.6.7 DescGetSessionIdOfSessionState
Modified:
8 Multi Identity Support
13.8 …send a positive response without
request after FBL flash job Katrin Thurow
2011-09-19
3.04.00
Added:
13.12…use “Dynamic Normal Addressing
Multi TP” with multiple tester
Modified:
13.11 …use Multiple Addressing
Katrin Thurow
2011-11-27
3.05.00
Added:
12.6.17 “Spontaneous Response”
transmission
Modified:
6.2.1 Global CANdesc Settings
Patrick Rieder
2013-01-23 3.06.00
Added:
10 Generic Processing Notifications
12.6.18 Generic Processing Notifications
Modified:
6.2.1 Global CANdesc Settings
12.6.4 Service callback functions
12.6.9 Ring Buffer Mechanism
Small fixes
2015, Vector Informatik GmbH
Version: 3.09.00
4 / 158
based on template version 5.1.0
Technical Reference CANdesc
Patrick Rieder
2013-05-27 3.07.00
Added:
11 Busy Repeat Responder Support
Modified:
13.12 …use “Dynamic Normal Addressing
Multi TP” with multiple tester
Patrick Rieder
2014-07-19 3.08.00
Added:
5.2 Configure the default session state in the
CDD
Modified:
12.6.5 Unknown (User) Service Handling
-
Consistent naming of the Unknown
Service Handling
12.6.17.1
DescSendApplSpontaneousResponse () -
Correct API name
-
Added missing pre-condition
-
Correct spelling and formatting
issues
Patrick Rieder
2014-11-27
3.08.01
Added:
5.3 Configuration of Mode 0x06 in the CDD
file
9.1 ReadDTCInformation (SID $19)
Modified:
Table 6-1
-
Setting “Faultmemory Iteration
Limiter” is dependent on OEM
Amr Elazhary
2015-07-31 3.09.00
Added:
9.1 Clear Diagnostic Information (SID $14)
(UDS2012)
Modified:
12.6.6.1 ApplDescCheckSessionTransition()
-
Added new signature, full message
context, to the callback.
2015, Vector Informatik GmbH
Version: 3.09.00
5 / 158
based on template version 5.1.0
Technical Reference CANdesc
Contents 1 History ........................................................................................................................... 2 2 Introduction................................................................................................................. 12 3 Documents this one refers to… ................................................................................. 13 4 Architecture Overview ................................................................................................ 14
4.1 CANdesc – Internal processing ........................................................................ 14
4.1.1 Diagnostic protocol .......................................................................... 14 4.1.2 How does this flow actually work? .................................................... 15 4.2 Application interface flow ................................................................................. 17
4.2.1 Session- and CommunicationControl ............................................... 17 5 Advanced Configuration ............................................................................................ 19
5.1 Configure DBC attributes for diagnostics ......................................................... 19 5.2 Configure the default session state in the CDD ................................................ 19 5.3 Configuration of Mode 0x06 in the CDD file ..................................................... 20 6 CANdesc Configuration in GENy ............................................................................... 21
6.1 Step One – Importing an ECU Diagnostic Description ..................................... 21 6.2 Step Two – ECU Diagnostic Configuration in GENy ......................................... 22
6.2.1 Global CANdesc Settings ................................................................. 23
6.2.1.1 Generic Processing Notifications (UDS2012) ................. 28 6.2.2 Service Specific Settings .................................................................. 29
6.2.2.1 Generic Service Settings ............................................... 29 6.2.2.2 Predefined (implemented) Services in CANdesc ............ 30 6.2.2.3 Signal Access Enabled Services .................................... 32 6.2.3 Timing Settings ................................................................................ 35 6.2.4 Security Access Settings (UDS2006) ............................................... 36 6.2.5 Security Access Settings (UDS2012) ............................................... 38 6.2.6 Scheduler Settings ........................................................................... 39 7 CANdescBasic Configuration in GENy ..................................................................... 42
7.1 Global CANdescBasic Settings ........................................................................ 42 7.2 Service Specific Settings .................................................................................. 42 7.3 Timing Settings ................................................................................................ 43 7.4 Diagnostic State Configuration ......................................................................... 43 8 Multi Identity Support ................................................................................................. 47
8.1 Single Identity Mode ........................................................................................ 47 2015, Vector Informatik GmbH
Version: 3.09.00
6 / 158
based on template version 5.1.0
Technical Reference CANdesc
8.1.1.1 Configuration in CANdela............................................... 47 8.1.1.2 Configuration in GENy ................................................... 47 8.2 VSG Mode ....................................................................................................... 47
8.2.1 Implementation Limitations............................................................... 48 8.2.2 Configuration in CANdela ................................................................. 49 8.2.3 Configuration in CANdela ................................................................. 50 8.2.4 Configuration in GENy ..................................................................... 51 8.3 Multi Identity Mode ........................................................................................... 51 9 Diagnostic Service Implementation Specifics .......................................................... 52
9.1 Clear Diagnostic Information (SID $14) (UDS2012) ......................................... 52
9.1.1 Tasks performed by CANdesc .......................................................... 52 9.1.2 Task to be performed by the Application ........................................... 52 9.2 ReadDTCInformation (SID $19) ....................................................................... 52
9.2.1 Limitations of the service .................................................................. 52 9.3 ReadDataByIdentifier (SID $22) ....................................................................... 52
9.3.1 Limitations of the service .................................................................. 54 9.3.2 Single PID mode .............................................................................. 55
9.3.2.1 Sending a positive response using linear buffer
access ........................................................................... 55 9.3.2.2 Sending a positive response using ring buffer access .... 56 9.3.2.3 Sending a negative response ......................................... 57 9.3.3 Multiple PID mode ............................................................................ 57
9.3.3.1 Pure linear buffer configuration ...................................... 58
9.3.3.1.1 Sending a positive response ...................... 58 9.3.3.1.2 Sending a negative response ..................... 59 9.3.3.2 Ring buffer active configuration ...................................... 59
9.3.3.2.1 Sending a positive response ...................... 61 9.3.3.2.2 Sending a negative response ..................... 62 9.3.3.2.3 PostHandler execution rule ........................ 63 9.4 DynamicallyDefineDataIdentifier (SID $2C) (UDS) ........................................... 63
9.4.1 Feature set ....................................................................................... 64 9.4.2 API Functions................................................................................... 64 9.4.3 Sequence Charts ............................................................................. 65 9.5 Read/Write Memory by Address (SID $23/$3D) (UDS) .................................... 67
9.5.1 Tasks performed by CANdesc .......................................................... 68 9.5.2 Task to be performed by the Application ........................................... 68 9.5.3 Repeated service calls ..................................................................... 68 10 Generic Processing Notifications .............................................................................. 69 10.1 Using dynamically defined data Identifier ......................................................... 70 2015, Vector Informatik GmbH
Version: 3.09.00
7 / 158
based on template version 5.1.0
Technical Reference CANdesc
11 Busy Repeat Responder Support (UDS2006 and UDS2012) .................................... 71 11.1 Configuration in GENy ..................................................................................... 72 12 CANdesc API ............................................................................................................... 73 12.1 API Categories ................................................................................................. 73
12.1.1 Single Context .................................................................................. 73 12.1.2 Multiple Context (only CANdesc)...................................................... 73 12.2 Data Types ....................................................................................................... 73 12.3 Global Variables ............................................................................................... 73 12.4 Constants ........................................................................................................ 73
12.4.1 Component Version.......................................................................... 73 12.5 Macros ............................................................................................................. 74
12.5.1 Data exchange ................................................................................. 74
12.5.1.1 Splitting 16 bit data ........................................................ 74 12.5.1.2 Splitting 32 bit data ........................................................ 74 12.5.1.3 Assembling 16 bit data ................................................... 74 12.5.1.4 Assembling 32 bit data ................................................... 75 12.6 Functions ......................................................................................................... 75
12.6.1 Administrative Functions .................................................................. 75
12.6.1.1 DescInitPowerOn()......................................................... 75 12.6.1.2 DescInit() ....................................................................... 76 12.6.1.3 DescTask() ..................................................................... 76 12.6.1.4 DescStateTask() ............................................................ 77 12.6.1.5 DescTimerTask() ............................................................ 78 12.6.1.6 DescGetActivityState() ................................................... 79 12.6.2 Multi Variant Configuration Functions ............................................... 80
12.6.2.1 DescInitConfigVariant() .................................................. 80 12.6.2.2 DescGetConfigVariant() ................................................. 81 12.6.3 Service Functions ............................................................................ 82
12.6.3.1 DescSetNegResponse() ................................................ 82 12.6.3.2 DescProcessingDone() .................................................. 83 12.6.4 Service callback functions ................................................................ 84
12.6.4.1 Service PreHandler ........................................................ 86 12.6.4.2 Service MainHandler ...................................................... 87 12.6.4.3 Service PostHandler ...................................................... 89 12.6.5 Unknown (User) Service Handling ................................................... 89
12.6.5.1 How it works .................................................................. 90 12.6.5.2 ApplDescCheckUserService() ........................................ 90 12.6.5.3 DescGetServiceId()........................................................ 91 12.6.5.4 Unknown (User) Service MainHandler ........................... 92 12.6.5.5 Unknown (User) Service PostHandler ............................ 93 2015, Vector Informatik GmbH
Version: 3.09.00
8 / 158
based on template version 5.1.0
Technical Reference CANdesc
12.6.6 Session Handling ............................................................................. 93
12.6.6.1 ApplDescCheckSessionTransition() ............................... 93 12.6.6.2 DescSessionTransitionChecked() .................................. 95 12.6.6.3 DescIsSuppressPosResBitSet () .................................... 95 12.6.6.4 ApplDescOnTransitionSession() .................................... 96 12.6.6.5 DescSetStateSession() .................................................. 97 12.6.6.6 DescGetStateSession() ................................................. 98 12.6.6.7 DescGetSessionIdOfSessionState ................................. 99 12.6.7 CommunicationControl Handling ...................................................... 99
12.6.7.1 ApplDescCheckCommCtrl() ......................................... 100 12.6.7.2 DescCommCtrlChecked() ............................................ 100 12.6.8 Periodic call of ‘Service MainHandler’ ............................................ 101
12.6.8.1 DescStartRepeatedServiceCall() ................................. 101 12.6.8.2 DescStartMemByAddrRepeatedCall() .......................... 103 12.6.9 Ring Buffer Mechanism .................................................................. 103
12.6.9.1 DescRingBufferStart() .................................................. 104 12.6.9.2 DescRingBufferWrite() ................................................. 105 12.6.9.3 DescRingBufferCancel() .............................................. 106 12.6.9.4 DescRingBufferGetFreeSpace() .................................. 107 12.6.9.5 DescRingBufferGetProgress()...................................... 108 12.6.10 Signal Interface of CANdesc .......................................................... 108 12.6.10.1 ApplDesc<Signal-Handler>() ....................................... 109
12.6.10.2 Configuration of direct signal access ............................ 109 12.6.11 State Handling (CANdesc only) ...................................................... 110 12.6.11.1 DescGetState<StateGroup>() ...................................... 110
12.6.11.2 DescSetState<StateGroup>() ....................................... 111
12.6.11.3 ApplDescOnTransition«StateGroup»() ......................... 112 12.6.12 Force “Response Correctly Received - Response Pending” transmission ................................................................................... 113
12.6.12.1 DescForceRcrRpResponse() ....................................... 113
12.6.12.2 ApplDescRcrRpConfirmation() ..................................... 114 12.6.13 DynamicallyDefineDataIdentifier ($2C) (UDS) functions ................ 114 12.6.13.1 DescMayCallStateTaskAgain() ..................................... 115
12.6.13.2 ApplDescCheckDynDidMemoryArea() ......................... 116
12.6.13.3 Non-volatile memory support ....................................... 117 12.6.13.3.1 DescDynDefineDidPowerUp() .................. 119
12.6.13.3.2 DescDynIdMemContentRestored () ......... 120
12.6.13.3.3 DescDynDefineDidPowerDown () ............ 121
12.6.13.3.4 ApplDescStoreDynIdMemContent () ........ 122
12.6.13.3.5 ApplDescRestoreDynIdMemContent () .... 123 12.6.14 Memory Access Callbacks ............................................................. 123 2015, Vector Informatik GmbH
Version: 3.09.00
9 / 158
based on template version 5.1.0
Technical Reference CANdesc
12.6.14.1 ApplDescReadMemoryByAddress() ............................. 123
12.6.14.2 ApplDescWriteMemoryByAddress() ............................. 125 12.6.15 Flash Boot Loader Support ............................................................ 125 12.6.15.1 DescSendPosRespFBL() ............................................. 126
12.6.15.2 ApplDescInitPosResFblBusInfo() ................................. 127 12.6.16 Debug Interface / Assertion ............................................................ 127 12.6.16.1 ApplDescFatalError() ................................................... 127 12.6.17 “Spontaneous Response” transmission .......................................... 131 12.6.17.1 DescSendApplSpontaneousResponse () ..................... 131
12.6.17.2 ApplDescSpontaneousResponseConfirmation() .......... 133 12.6.18 Generic Processing Notifications.................................................... 134 12.6.18.1 ApplDescManufacturerIndication ................................. 134
12.6.18.2 ApplDescManufacturerConfirmation ............................ 135
12.6.18.3 ApplDescSupplierIndication ......................................... 136
12.6.18.4 ApplDescSupplierConfirmation .................................... 137 13 How To… ................................................................................................................... 139 13.1 …implement a protocol service MainHandler ................................................. 139 13.2 …implement a service MainHandler............................................................... 142 13.3 …implement a Signal Handler........................................................................ 143 13.4 …implement a Packet Handler ....................................................................... 144 13.5 …implement a state transition function .......................................................... 144 13.6 …work with the ring-buffer mechanism .......................................................... 146
13.6.1 with asynchronous write ................................................................. 146 13.6.2 with synchronous write ................................................................... 148 13.7 …prevent the ECU going to sleep while diagnostic is active .......................... 149 13.8 …send a positive response without request after FBL flash job ..................... 150 13.9 …enforce CANdesc to use ANSI C instead of hardware optimized bit type .... 150 13.10 …configure Extended Addressing .................................................................. 151
13.11 …use Multiple Addressing .............................................................................. 151
13.12 …use “Dynamic Normal Addressing Multi TP” with multiple tester ................. 153 14 Related documents ................................................................................................... 156 15 Glossary .................................................................................................................... 157 16 Contact ...................................................................................................................... 158
2015, Vector Informatik GmbH
Version: 3.09.00
10 / 158
based on template version 5.1.0
Technical Reference CANdesc
Illustrations Figure 3-1: Manuals and References for CANdesc .............................................................. 13 Figure 4-1: General request flow .......................................................................................... 14 Figure 4-2: DESC run diagram ............................................................................................. 15 Figure 4-3: Request message mapping ............................................................................... 16 Figure 4-4: Request processing stages ................................................................................ 17 Figure 5-1 Default session state configuration in the CDD ................................................... 19 Figure 6-1 CANdesc GENy startup screen ........................................................................... 21 Figure 6-2 Example of GENy global CANdesc settings ........................................................ 23 Figure 6-3 Activated feature “Generic Processing Notifications” ........................................... 28 Figure 6-4 GENy diagnostic service overview ...................................................................... 29 Figure 6-5 GENy generic sub-service setup ......................................................................... 30 Figure 6-6 GENy predefined sub-service setup .................................................................... 31 Figure 6-7 GENy signal API enabled sub-service setup ....................................................... 32 Figure 6-8 GENy signal view of a sub-service ...................................................................... 33 Figure 6-9 GENy signal handler types .................................................................................. 33 Figure 6-10 GENy direct access signal handler settings ...................................................... 34 Figure 6-11 GENy CANdesc timing parameters ................................................................... 36 Figure 6-12 GENy CANdesc security access parameters .................................................... 37 Figure 6-13 Security settings in GENy ................................................................................. 38 Figure 6-14 GENy CANdesc scheduler parameters ............................................................. 40 Figure 7-1 CANdescBasic add a user session ..................................................................... 43 Figure 7-2 CANdescBasic change user session name, id or completely delete user session ..................................................................................................... 44 Figure 7-3 CANdescBasic session configuration at service overview ................................... 45 Figure 7-4 CANdescBasic session configuration at service Id level ..................................... 45 Figure 7-5 CANdescBasic session configuration at sub-service level................................... 46 Figure 8-1 CANdesc multi identity mode .............................................................................. 48 Figure 8-2 Defining VSGs in CANdelaStudio ....................................................................... 50 Figure 8-3 Setting a VSG for service in CANdelaStudio ....................................................... 51 Figure 9-1: Linearly written positive response on single PID request.................................... 55 Figure 9-2: “On the fly” response data writing. ..................................................................... 56 Figure 9-3: Negative response on single PID ....................................................................... 57 Figure 9-4: Linearly written positive response on multiple PIDs (global ring buffer option is off) ............................................................................................................ 58 Figure 9-5: Negative response on multiple PIDs (global ring buffer option is off) .................. 59 Figure 9-6: Linearly written response data on multiple PIDs (global ring buffer option is on) 62 Figure 9-7: Negative response on multiple PIDs (global ring buffer option is on) .................. 62 Figure 9-8: Post-Handler execution sequence. .................................................................... 63 Figure 9-9: Defining a DDID. ................................................................................................ 66 Figure 9-10: Reading a DDID. .............................................................................................. 67 Figure 10-1 Call order of Manufacturer- and Supplier-Notficiation ........................................ 69 Figure 10-2 Read out a DDID with generic processing notifications ..................................... 70 Figure 11-1 Illustration of the feature BusyRepeatResponder .............................................. 71 Figure 11-2 Example of the “Number of Rx(Tx) Channels” settings ...................................... 72 Figure 12-1 DynDID definition restore and tester interaction .............................................. 118 Figure 12-2 Store DynDID definitions ................................................................................. 119 Figure 13-1 GENy TP configuration ................................................................................... 151 Figure 13-2 GENy TP callbacks ......................................................................................... 152 Figure 13-3 GENy TP callbacks (physical addressing) ....................................................... 153 Figure 13-4 GENy TP callbacks (functional addressing) .................................................... 154
2015, Vector Informatik GmbH
Version: 3.09.00
11 / 158
based on template version 5.1.0

Technical Reference CANdesc
2 Introduction This document has not the job to describe the diagnostic itself. The focus of this document
is the technical aspects of the CANdesc component.
Please note
We have configured the programs in accordance with your specifications in the
questionnaire. Whereas the programs do support other configurations than the one
specified in your questionnaire, Vector’s release of the programs delivered to your
company is expressly restricted to the configuration you have specified in the
questionnaire.
2015, Vector Informatik GmbH
Version: 3.09.00
12 / 158
based on template version 5.1.0



Technical Reference CANdesc
3 Documents this one refers to… > User Manuals CANdesc and CANdescBasic (one for both)
> Docu OEM
User ManualTechnicalTechnicalReferenceReferenceGeneralOEMYou are here Figure 3-1: Manuals and References for CANdesc
All common topics with CANdesc and CANdescBasic are described within this technical
reference very detailed.
Read all about OEM-specific differences in the TechnicalReference_OEM.
For faster integration, please refer to the product’s corresponding user manual CANdesc
or CANdescBasic.
2015, Vector Informatik GmbH
Version: 3.09.00
13 / 158
based on template version 5.1.0
Technical Reference CANdesc
4 Architecture Overview This chapter should describe the internal structure and behavior of the CANdesc
component.
4.1 CANdesc – Internal processing 4.1.1 Diagnostic protocol The communication described in the diagnostic protocol consists of a ping-pong
communication between a tester (client) and an ECU (server). The tester requests a
service in the ECU by transmitting a request to him. The ECU should response with a
positive response, if the result of this service is valid or the action is prepared to be done.
Is the result negative or the action could not be executed, the ECU should respond
negative.
The validity checks have typically the same pattern for all services (as shown in Figure
4-1: General request flow). These components which are included in this flow, build up the
main base of the CANdesc component.
ApplicationPrehandler optionalMainhandlerPosthandler optional{
{
{
....
}
}
DescProcessingDone( );
}
Diagnostics - CANdescCheck
SvcCheck
SvcInstCheck
SessionCheck
FormatACKt
positive ResponseRequestnegative ResponseTester Figure 4-1: General request flow
2015, Vector Informatik GmbH
Version: 3.09.00
14 / 158
based on template version 5.1.0
Technical Reference CANdesc
4.1.2 How does this flow actually work? The picture below shows a simply structured description of the module functionality.
Request receptionDispatching the requestIdle mode/Awaiting requestProcessing the requestFinishing processing of the request Figure 4-2: DESC run diagram
Let’s assume that the component is currently in the
“Awaiting request” state.
In this state
it waits for the next diagnostic request and if it is needed – it provides also timing
monitoring.
Once a diagnostic request transmission was initiated from the transport layer, the
component enters in the state
“Request reception”. If the reception is finished, further
physical requests will be blocked until the response is sent. Depending on the used OEM a
functional request in the ISO 14230 standard will be handled parallel1 to physical request.
The ISO 14229-1 standard is more restricted to the parallel handling. Except the Tester
Present Service no other service could be handled parallel.
After the reception of the request is completed the request processing will be prepared.
The component is in the
“Dispatching request” state. The processing of the request is
done at a task level within the next call of the DescTask() function.
First the SID is checked whether supported or not. If not a negative response
‘ServiceNotSupported’ (NRC $11) will be sent.
Next step is to check if the supported SID is permitted in the current Session (Diagnostic
Mode). If not, the negative response ‘ServiceNotSupportedInTheCurrentSession’ (NRC
$7F) is sent automatically by the CANdesc component.
1 Not all services could be handled parallel.
2015, Vector Informatik GmbH
Version: 3.09.00
15 / 158
based on template version 5.1.0




























Technical Reference CANdesc
1Byte n Bytes (n=0..N)
m
Bytes (m = 0..M)
SID
SID _EXT
Application data
Service instance qualificatio n
“Request head
“
Figure 4-3: Request message mapping
After that the CANdesc component validates, if the sub-service (service instance) is
supported or not. This is implemented with a powerful binary search. If the service
instance is not supported, the request will be rejected with the corresponding error code
‘SubFunctionNotSupported’ (NRC $11, for service which have sub-functions) or
‘InvalidFormat’ (NRC $13, for service with data identifiers).
For each service instance which is supported by the current configuration, the CANdesc
component knows the exact length of most requests. (Some requests use variable data
length elements thus a fixed length doesn’t exist.) If the length is known and it does not
match, the dispatcher will reject this request (dependent to the manufacturer specification).
If the complete request length is not known, the application has to do this job.
If the service instance is found, the state checks (e.g. ‘Security Level’) will be performed. If
all of them are passed then the component enters the state
“Processing the request” in
the diagram above. This state consists of several parts that are represented in more
detailed structure shown below. The dotted lines reveal the optional parts for the
implementation. For example – the Pre-, Post- and SignalHandlers are optional and might
not be implemented.
2015, Vector Informatik GmbH
Version: 3.09.00
16 / 158
based on template version 5.1.0
Technical Reference CANdesc
Request analyzedPreHandlerMainHandlerSignal-Handler #0Signal-Handler #1Signal-Handler #kPostHandler Figure 4-4: Request processing stages
After the response is composed CANdesc must be informed about, to start the
transmission of the final response. CANdesc is doing the handshake with the Tester
(automatic transmission of RCR-RP) while the state
“Processing the request” is active.
Within the end of the transmission the state “
Finishing processing of the request” is
entered and the PostHandler (if configured) is called. In this PostHandler the application
has to do the closing (e.g. updating a state machine, prepare the ECU for a reset …). The
session state for example (which is managed by CANdesc) is also updated in a
PostHandler.
4.2 Application interface flow 4.2.1 Session- and CommunicationControl The services SessionControl and CommunicationControl are typically handled by
CANdesc. But the application still has the possibility to reject these service requests. You
can find a detailed description in chapte
r 12.6.6 Session Handling and in chapte
r 12.6.7
CommunicationControl Handling also.
2015, Vector Informatik GmbH
Version: 3.09.00
17 / 158
based on template version 5.1.0
Technical Reference CANdesc
IDLE
Receive a Request
Search
SID
SID $28
Supported Unsupported
SID $10
(SID $29)
SID $xx
SID $xx
ApplDesc<PreHandler>ApplDesc<PreHandler>ApplDesc<PreHandler>callbackcallbackcallbackApplDescCheckSessionTransitionApplDescCheckCommCtrlApplDesc<MainHandler>{{{ ... ... ...DescSessionTransitionChecked();DescCommCtrlChecked(); DescProcessingDone();}}}Transmit
Transmit positive
Transmit positive
Transmit positive
negative
response $50
response $68
response $xx
response
NRC $11
WAIT
WAIT
WAIT
TX acknowledge
TX acknowledge
TX acknowledge
$50
$68
$xx
ApplDescOnCommunicationEnabledApplDescOnSessionTransitionApplDescOnCommunicationDisabledApplDesc<PostHandler>>optional - not all OEMs<IDLE
2015, Vector Informatik GmbH
Version: 3.09.00
18 / 158
based on template version 5.1.0

Technical Reference CANdesc
5 Advanced Configuration 5.1 Configure DBC attributes for diagnostics If the diagnostic messages shall be defined in the communication data-base file (DBC),
and not received via CANdriver ranges (e.g. in case of normal fixed or extended
addressing), the following attributes in the DBC file must exist and shall be set as shown
below.
Attribute Name Object Value Values Description Type Type the default value is
written in bold
DiagRequest
Message Enum
No Specifies (Yes) that the message is a diagnostic
Yes
physical USDT request message.
DiagResponse
Message Enum
No Specifies (Yes) that the message is a diagnostic
Yes
USDT response message.
DiagState
Message Enum
No Specifies (Yes) that the message is a diagnostic
Yes
functional USDT request message.
DiagUudtResponse Message Enum
false Specifies (true) that the message is a diagnostic
true
UUDT response message.
Table 5-1: DBC file diagnostic message attributes
5.2 Configure the default session state in the CDD The configuration of the default session state in the CDD must comply with the following
conditions:
The
qualifier must be set to „Default“ (the name can be different)
It must be the first item in the list of states
An example configuration is shown in
Figure 5-1. Figure 5-1 Default session state configuration in the CDD
2015, Vector Informatik GmbH
Version: 3.09.00
19 / 158
based on template version 5.1.0

Technical Reference CANdesc
Caution
An incorrectly specified default session state qualifier may result in a compile error.
5.3 Configuration of Mode 0x06 in the CDD file If available, CANdesc offers a basic support for the OBD services. For each OBD service
CANdesc will provide one callout on SID level where the user has to implement the
functionality of service 0x06. However, to be able to generate CANdesc properly, OBD
service 0x06 has to be configured properly in the CDD. How to configure the service
properly is described in the application note /AN-IDG-1-013/ available in the download
center on our homepage.
2015, Vector Informatik GmbH
Version: 3.09.00
20 / 158
based on template version 5.1.0

Technical Reference CANdesc
6 CANdesc Configuration in GENy Since version 6.00.00, the CANdesc configuration concept has been improved by splitting
the concrete ECU parameterization and software integration from the diagnostic
specification.
The configuration of CANdesc in GENy consists of two important steps:
Importing a diagnostic description file. Currently only CANdela (CDD) files are supported
therefore in further only the term CDD file will be used.
Setup all service options required by the application like:
Configure the service handlers (pre-, main- and post-handlers)
Setup the service specific settings, like maximum number of dynamically defined items per
DynDID, size of scheduler for periodic data reading, etc.
Setup timing parameters (e.g. periodic rates).
The second step is optional, since after importing a CDD file all important settings will be
already prepared for usage. If there are missing or invalid settings, GENy will notify you at
generation time.
6.1 Step One – Importing an ECU Diagnostic Description After activating the CANdesc component in GENy, you will have the following view:
Figure 6-1 CANdesc GENy startup screen
At this time GENy does not have any CDD file and cannot generate CANdesc. You have to
specify a CDD file, using the button on the option “CANdela document name”.
After selecting the CDD file, the CANdesc component tree view will look like:
2015, Vector Informatik GmbH
Version: 3.09.00
21 / 158
based on template version 5.1.0



Technical Reference CANdesc
Info
Please note, the diagnostic buffer size is now set to a non-zero value. At CDD import
time, GENy calculates a statistic over all services with simple, linear data structure and
sets the buffer size to fit the longest request resp. response message. The message
window will show you which service requires the suggested buffer size:
Complex services like reading the fault memory information or
upload/download/transferdata are excluded from this statistic, since the worst case
response calculation is not possible.
You can still set another value for the buffer size, even lower as the size suggested by
GENy. At generation time, the code generator will check again the set buffer size and
consider more options you have changed (like RingBuffer support) and notify you if the
buffer size is too small.
Now you can try to generate your diagnostic layer, using the default settings.
6.2 Step Two – ECU Diagnostic Configuration in GENy Once the CDD content is imported, there are several options that can and shall be set up
for best match on your ECU integration needs.
2015, Vector Informatik GmbH
Version: 3.09.00
22 / 158
based on template version 5.1.0

Technical Reference CANdesc
What You Can Configure in GENy The goal of splitting the ECU integration configuration from the ECU diagnostic
specification is to provide a simplified view on what the ECU diagnostic application
developer is able to configure without danger of changing the diagnostic specification
provided by the OEM.
If a CANdesc parameter is not available in the source diagnostic description (CDD file),
you will be able to edit it in GENy, even if it is relevant for the diagnostic specification.
The chapters below will show you all configuration parameters of CANdesc that can be set
up in GENy.
What You Can Not Configure in GENy All diagnostic parameters that could affect the ECU behaviour regarding its diagnostic
specification, provided by the concrete OEM or would lead to inconsistency between the
tester expectations on the ECU behaviour are not editable in GENy. If a change is required
on such a parameter, the diagnostic description source shall be modified, to guarantee that
the OEM or/and the tester will take this change into account.
6.2.1 Global CANdesc Settings Under the generic settings you will find the options that affect the overall module
performance, independently of the diagnostic services that shall be supported. In the
picture and the table below follows the description of the settings for CANdesc.
Figure 6-2 Example of GENy global CANdesc settings
2015, Vector Informatik GmbH
Version: 3.09.00
23 / 158
based on template version 5.1.0
Technical Reference CANdesc
Attribute Name Availability Value Type Values Description The default
value is written
in bold
Cycle Time [ms]
Always available.
Integer
10 The DescTask (resp.
1..255
DescTimerTask) function must be
called EXACTLY in the time period
specified here.
This is important since the time
constant will be converted into a
number of function calls and if this
setting doesn't match the real call
cycle, the component internal
timeout monitors will not function
properly.
Generate CANdesc Always available.
Button
This feature is only available after
you have generated the whole
CANbedded package.
NOTE: If you run into problems,
generate the whole package again!
Number of ‘Busy-
OEM dependent
Integer
0 The value is the maximum count of
RepeatRequest’
availability.
0..255
parallel handled diagnostic
responded
requests. Only the first diagnostic
Requests
request will be processed, all other
(additional) request, which will be
received while the first one is in
process, will be also received, but
only responded with NRC $21
('BUSY - repeat request'). If there
are more requests onto the bus
than this number, only the first N
will be responded - all other will be
just ignored.
Flashable ECU
OEM dependent
Boolean
False Depending on the car
availability.
True
manufacturer this option has
different effects. Please, see the
OEM specific technical reference
document for more information.
Ring Buffer Support Always available.
Boolean
False In case your ECU shall send a
True
very long positive response for
some services (usually when
reading fault memory) you can
reserve enough RAM for the
diagnostic buffer to handle the
longest possible response length,
or you can use the built-in ring-
buffer mechanism which allows
usage of smaller buffer. The linear
buffer usage saves ROM and run-
time but needs more RAM, the
ring-buffer saves RAM (you may
send 4095 Byte response with a
20Byte buffer) but requires more
ROM and causes run-time
overhead when used. NOTE: This
2015, Vector Informatik GmbH
Version: 3.09.00
24 / 158
based on template version 5.1.0
Technical Reference CANdesc
Attribute Name Availability Value Type Values Description The default
value is written
in bold
option just unlocks the built-in
support, but the selection usage of
the feature is done at run-time by
your application (for each service
independently).
Forced RCR
In some cases (e.g. prior jump into
-RP
OEM dependent
Boolean
False Response
the FBL (FlashBootLoader), ECU
availability.
True
busy so no task function can be
called for long period of time) it is
necessary to prevent the tester
from ECU response timeout.
Enabling this feature you will be
able to send a RCR-RP
(ResponseCorrectlyReceived-
ResponsePending) response any
time during an active service
processing (main-handler called
but no DescProcessingDone has
been called yet).
Repeated Service
Always available.
Enum
Deactivated In some cases (usually for slow
Call Type
Always
services like reading from
Individual
EEPROM) it is useful to let the
component to poll your application
(service main-handler) until the
service execution is completed.
Otherwise you have to leave the
service's main-handler function
and trigger an own additional
polling task and finalize the service
from there. Using the built-in
polling mechanism you will save
ROM and run-time. Also it prevents
from confusing code structures.
Always: Each main-handler will be
called as long as the application
didn’t call
DescProcessingDone(). Individual: Each main-handler will
decide by itself if it will be called
once or as long as the application
didn’t call
DescProcessingDone(). Production Mode
OEM dependent
Boolean
False Enabling the production mode will
availability.
True
set all options in the possible
safest (uncritical) value.
Some car manufacturers don't
allow all of the features in
production, so they will be turned
off.
Spontaneous
Available if Service Boolean
This setting enables the possibility
False Response
to send diagnostic responses
0x86 is part of the
True
diagnostic
without a preceding request.
configuration.
This feature is needed for Service
0x86 with Transmission Type I.
2015, Vector Informatik GmbH
Version: 3.09.00
25 / 158
based on template version 5.1.0
Technical Reference CANdesc
Attribute Name Availability Value Type Values Description The default
value is written
in bold
The spontaneous response can be
triggered via the API
DescSendApplSpontaneousRespo
nse.
Supplier Notification Available if
Boolean
False If this option is enabled, CANdesc
Support
CANdesc
True
notifies the application on incoming
according to ISO
service requests and outgoing
14229-1 2012 is
responses. CANdesc only notifies
used.
the application if the requested
service is supported in the active
session and security state. For
more details see
10 Generic
Processing Notifications Manufacturer
Available if
Boolean
False If this option is enabled, CANdesc
Notification Support CANdesc
True
notifies the application on incoming
according to ISO
service requests and outgoing
14229-1 2012 is
responses. CANdesc notifies the
used.
application right before the
processing of the request starts
and after a response has been
sent. For more details see
10
Generic Processing Notifications Unknown Services
OEM dependent
Boolean
False In some cases if the diagnostic
Acceptance
availability.
True
database doesn't contain all
necessary service Ids, or you need
a (some) test identifier(s), you can
enable this option which will
redirect all received requests with
unknown service Ids to your
application for additional
acknowledgment and processing.
Unknown Services
OEM dependent
Boolean
False If the option 'Unknown Services
Post Handler Calls
availability.
True
Acceptance' is enabled, you may
use this feature to be notified each
time an unknown service
processing has been
accomplished. This post handler
usage is the same as the one of
the normal services post handlers.
Application Interface Always available.
Boolean
False The SW component provides built-
Assertions
True
in debug support (assertion) to
ease up the integration and test
into the project.
In general, the usage of assertions
is recommended during the
integration and pre-test phases. It
is not recommended to enable the
assertions in production code due
to increased runtime and ROM
needs. The assertion checks the
correctness of the assigned
2015, Vector Informatik GmbH
Version: 3.09.00
26 / 158
based on template version 5.1.0
Technical Reference CANdesc
Attribute Name Availability Value Type Values Description The default
value is written
in bold
condition and calls an error-
handler in case this fails. The error
handler is called with an error and
line number. You can find
information about the defined error
numbers in the Desc.h file.
Internal Assertions
Always available.
Boolean
False The SW component provides built-
True
in debug support (assertion) to
ease up the integration and test
into the project.
In general, the usage of assertions
is recommended during the
integration and pre-test phases. It
is not recommended to enable the
assertions in production code due
to increased runtime and ROM
needs. The assertion checks the
correctness of the assigned
condition and calls an error-
handler in case this fails. The error
handler is called with an error and
line number. You can find
information about the defined error
numbers in the Desc.h file.
List of DANIS
Always available.
String List
Add an arbitrary list of DANIS
drivers
drivers for custom bus access.
Each entry here will result in a user
driver, which can be used to
connect CANdesc to arbitrary
transport layers.
Example:
Adding a driver name “MostTp” will
force CANdesc to generate
templates for a driver with this
name. You will have only to
implement the functions of the
driver skeleton.
UUDT Message
Available only if
Integer
100 This is the maximum time after
Confirmation
UUDT message
1..65535
which a UUDT (Unacknowledged
Timeout [ms]
transmission is
Unsegmented Data Transfer)
supported.
message will be deleted from the
CAN drive request queue and (if
possible) will be replaced by the
next queued message.
Faultmemory
OEM dependent
Integer
0 Limit the iteration depth for fault
Iteration Limiter
availability.
0..255
memory read services.
2015, Vector Informatik GmbH
Version: 3.09.00
27 / 158
based on template version 5.1.0

Technical Reference CANdesc
Attribute Name Availability Value Type Values Description The default
value is written
in bold
Some fault memory ($19) services
can consume much runtime when
performed en bloc. To reduce the
run time of the CANdesc task, use
this option to limit the iteration
depth of the fault memory access
function so your controller can
handle the workload.
ATTENTION: Depending on your
Tp timeout settings, to lower the
number of iterations can result in
an aborted transmission due to
buffer underrun.
A value of 0 (zero) will disable any
limitation.
Variant Mode
OEM dependent
Enum
None Note: This setting is independent
Selection
availability.
Multi Identity from communication identities!
Mode
None: The diagnostics support one
VSG Mode
configuration only.
Multi Identity Mode: The
diagnostics support different
diagnostic variants. One variant is
active a time.
VSG Mode: Diagnostic Entities
(SubServices, DTCs...) are
grouped into VSGs. Several VSGs
can be active at a time.
Table 6-1
GENy global CANdesc settings
6.2.1.1 Generic Processing Notifications (UDS2012) On activation of the feature “Generic Processing Notifications”, GENy shows the names of
the additional callbacks that will be generated. The names of the callbacks are fixed and
cannot be modified (see
Figure 6-3). For a detailed description of the feature see chapter
10 Generic Processing Notifications. Figure 6-3 Activated feature “Generic Processing Notifications”
2015, Vector Informatik GmbH
Version: 3.09.00
28 / 158
based on template version 5.1.0

Technical Reference CANdesc
6.2.2 Service Specific Settings Once the CDD file is imported you can have an overview of the supported services of your
ECU:
Figure 6-4 GENy diagnostic service overview
On this level you can also configure all services that will be supported on service Id level
only.
6.2.2.1 Generic Service Settings Using the CANdesc component tree view you can explore the detailed settings for each
service and its sub-services (if available).
A generic sub-service setup looks like the picture below:
2015, Vector Informatik GmbH
Version: 3.09.00
29 / 158
based on template version 5.1.0

Technical Reference CANdesc
Figure 6-5 GENy generic sub-service setup
Almost all services have a very simple configuration view. You can see the main-handler is
always available and a preview of the call-back name is shown.
You can only add a pre- and / or a post-handler to such a service, if required.
6.2.2.2 Predefined (implemented) Services in CANdesc There are configurations (OEM dependent) where several services are fully implemented
by CANdesc. Such service can be, StartDiagnsoticSession, SecurityAccess,
DynamicallyDefinedDataIdentifier, ReadDataByPeriodicIdentifier, etc.
Those services that will not be handled by the application are marked in GENy as shown
on the picture:
2015, Vector Informatik GmbH
Version: 3.09.00
30 / 158
based on template version 5.1.0

Technical Reference CANdesc
Figure 6-6 GENy predefined sub-service setup
As you can see, the main-handler is grayed and marked as “implemented by CANdesc”.
The same can apply (depends on the service) also to the pre- and post-handlers of the
service.
In the example on the
Figure 6-6 GENy predefined sub-service setup you see that the pre-
handler is still free for usage. This means you can still implement a pre-handler to check
additional conditions prior CANdesc will be able to process the service. For other service it
could be also the post-handler free for implementation.
There are several services that make some exceptions to the predefined implementation
rule:
Service 0x2A:
PreHandler configuration is possible: If a pre-handler is required, it must be enabled on all
sub-functions
of
the
concrete
DID.
The
pre-handler
name
will
be
“ApplDescPreReadPeriodicDid<DID instance name>”.
PreHandler on “stop all” is not used by CANdesc and will not be considered during the
code generation even if it is enabled.
Main-Handler are set to “implemented by CANdesc” since the data reading call-back will
be the corresponding 0x22 DID service call. This means that if the corresponding service
0x22 DID has been set to use the “Signal API”, the periodic reading service will use it too.
Post-Handlers are not supported at all.
2015, Vector Informatik GmbH
Version: 3.09.00
31 / 158
based on template version 5.1.0

Technical Reference CANdesc
Service 0x2C:
PreHandler configuration is possible: If a pre-handler is required, it must be enabled on all
sub-functions
of
the
concrete
DID.
The
pre-handler
name
will
be
“ApplDescPreDynDefineDid<DID instance name>”.
PreHandler on “clear all” is not used by CANdesc and will not be considered during the
code generation even if it is enabled.
Main-Handler are set to “implemented by CANdesc” since the DID definition is always
done by CANdesc.
Post-Handler are not supported at all.
6.2.2.3 Signal Access Enabled Services Some services such as the UDS ones 0x22/0x2A and 0x2E, can be processed on signal
level. This means CANdesc will analyze the request/response data structure and generate
the service main-handler, leaving to the application only the task to provide the signal
values for the response, resp. to write the requested signal values to the ECU memory.
The setting view of such a service is shown below:
Figure 6-7 GENy signal API enabled sub-service setup
2015, Vector Informatik GmbH
Version: 3.09.00
32 / 158
based on template version 5.1.0


Technical Reference CANdesc
Note: For the read dynamically defined DID service, there is no signal access since they
are always implemented by CANdesc internally.
If the “Signal API” option is not enabled this service is to be implemented like any other
diagnostic service. The data object specific settings, described below, will have no effect
on the code generation.
If the “Signal API” option is enabled, CANdesc will generate per default a call-back function
for any data object (signal) the service contains. You can specify more options on each
signal, to achieve the maximum advantage of CANdesc – fully implemented diagnostic
service.
Figure 6-8 GENy signal view of a sub-service
You can have three types of signal handling:
Figure 6-9 GENy signal handler types
2015, Vector Informatik GmbH
Version: 3.09.00
33 / 158
based on template version 5.1.0


Technical Reference CANdesc
FAQ
Constant is only possible if the CDD file has contained constant value for the selected data
object. You can not specify in GENy a constant value for a signal handler.
In case of selected “Direct Access” signal handling, the following options will be enabled:
Figure 6-10 GENy direct access signal handler settings
Attribute Name Availability Value Values Description Type The default value is
written in bold
Signal Handler Type Only for signal API Enum
SignalHandler Select the type of signal handler
enabled services.
Constant
DirectAccess
Constant: The data value is
constant. The data value can be
used directly. This is used only
when the corresponding
subservice uses a signal API main
handler.
Signal Handler: Use a callback
function to get/set the data value.
This function is used only when the
corresponding subservice uses a
signal API main handler.
Direct Access: Directly use a
variable to access the data object.
Also, a signal API main handler
has to be used for this setting to
have any effect.
SignalHandler
Only for signal API String
<DataObjectQThis value is used as base for the
Function Base
enabled services
ualifier>+<Diasignal access function - depending
Name
and a signal
gInstanceQual on how the value is used, the
access through a
ifier> name entered here is prefixed with
2015, Vector Informatik GmbH
Version: 3.09.00
34 / 158
based on template version 5.1.0
Technical Reference CANdesc
Attribute Name Availability Value Values Description Type The default value is
written in bold
SignalHandler is
different prefixes, e.g
selected
ApplDescRead / ApplDescWrite.
You can override the default name,
by specifying an own signal base.
The Prefix (e.g. ApplDesc can not
be overridden).
Signal Variable
Only for signal API String
<DataObjectQThe name of the signal variable.
Name
enabled services
ualifier> Example:
and if
DirectAccess c_dataTemp
signal handling is
g_applData.bit0
selected
Signal Variable
Only for signal API Enum
Ram To create the proper extern
Prototype
enabled services
None
declaration to access the signal
and if
Const
variable, the proper access
DirectAccess User
modifiers have to be specified.
signal handling is
selected
None: No prototype is generated at
all. "DescType.h" where the user
has to define the real typedefs (for
structure access for example).
Ram: The variable is located in
RAM.
Const: The variable is located in
ROM.
User: Set a user defined prototype.
Signal Variable User Only for signal API String
Empty Set the prototype of the signal
Prototype
enabled services
variable.
and if
Example:
DirectAccess signal handling is
boolean
selected
EcuTempType
and if the Signal
Variable Prototype
is set to
User 6.2.3 Timing Settings GENy imports all possible timings that the diagnostic description source provides. Those
parameters that are available in the CDD file are considered as a part of the ECU
specification and are not modifiable in GENy. If a modification of those parameters is
required, please change their values in the diagnostic description file and re-import it in
GENy.
2015, Vector Informatik GmbH
Version: 3.09.00
35 / 158
based on template version 5.1.0


Technical Reference CANdesc
All other parameters can be set up manually, but the default value already matches the
OEM specification.
Figure 6-11 GENy CANdesc timing parameters
6.2.4 Security Access Settings (UDS2006) If the security access service is implemented by CANdesc (see the service handler on the
service 0x27 instances), you can set here the level specific attributes, like attempts to start
the delay time, delay time on power on, etc.
Caution
It is OEM specific property whether the security access parameters will be evaluated
security level specific or not. In case the security access service specification of the
concrete OEM requires only global configuration of these options, the code generator
will calculate the maximum value over all levels for each parameter and this value will
be used by the service implementation in CANdesc.
Example: Level 1 has “Attempt Counter” = 1, and Level 2 has for the same parameter =
3. CANdesc will use then for “Attempt Counter” = 3 for all security levels.
2015, Vector Informatik GmbH
Version: 3.09.00
36 / 158
based on template version 5.1.0

Technical Reference CANdesc
Figure 6-12 GENy CANdesc security access parameters
Attribute Name Availability Value Values Description Type The default value is
written in bold
Attempt Counter
Only if the
Integer
0 Specifies the maximum number of
SecurityAccess
1..255
failed attempts to unlock the ECU.
state group is
If this number is reached, a delay
available
for the next security access try will
be inserted.
If a non-zero value is entered, the
delay time must be set to a non-
zero value too.
Note: This parameter has only
effect only if the SecurityAccess
service is handled by CANdesc.
Initial Delay [ms]
Only if the
Integer
0 Specifies the delay time after the
SecurityAccess
1..65535
maximum retry attempt count has
state group is
been reached.
available
If a non-zero value is entered, the
2015, Vector Informatik GmbH
Version: 3.09.00
37 / 158
based on template version 5.1.0

Technical Reference CANdesc
Attribute Name Availability Value Values Description Type The default value is
written in bold
attempt count must be set to a
non-zero value too.
Note: This parameter has only
effect only if the SecurityAccess
service is handled by CANdesc.
PowerOn Delay [ms] Only if the
Integer
0 Specifies the delay time at power
SecurityAccess
1..65535
on.
state group is
available
If a non-zero value is entered, the
delay time must be set to a non-
zero value too.
Note: This parameter has only
effect only if the SecurityAccess
service is handled by CANdesc.
6.2.5 Security Access Settings (UDS2012) Due to the new features in CANdesc UDS2012, the configuration of the security levels in
GENy has changed.
Figure 6-13 Security settings in GENy
Attribute Name Availability Value Values Description Type The default value is
written in bold
Level Specific Failed Only if the
Boolean
False Switch to select whether a global
Access Attempt
SecurityAccess
True
false attempt counter and delay
Supervision
state group is
timer for all security levels shall be
available
used (false) or if each level has its
own false attempt counter and
delay timer (true).
Use Static Seed
Only if the
Boolean
False For each level can be selected if a
SecurityAccess
True
static seed is used (true) or not
state group is
(false). Static seed means that
2015, Vector Informatik GmbH
Version: 3.09.00
38 / 158
based on template version 5.1.0
Technical Reference CANdesc
Attribute Name Availability Value Values Description Type The default value is
written in bold
available
CANdesc stores the seed and re-
uses the seed in a positive
response to a seed request for that
level, until the level is unlocked.
Failed Attempt
Only if the
Integer
Value The number of failed security
Counter to Delay
SecurityAccess
imported from unlock attempts allowed before a
state group is
the Cdd file. delay is imposed between
available
0..65535
attempts.
Failed Attempt
Only if the
Integer
Value The delay time in ms which is
Delay [ms]
SecurityAccess
imported from imposed if the Failed Attempt
state group is
the Cdd file. Counter limit has been reached.
available
0..65535
Further security access attempts
are discarded, until the delay has
expired.
PowerOn Delay [ms] Only if the
Integer
Value The delay time in ms which is
SecurityAccess
imported from imposed when the ECU is
state group is
the Cdd file. powered on. Requests to unlock
available
0..65535
the security level are declined until
the delay has expired.
6.2.6 Scheduler Settings If the ECU shall support the periodic data reading service, the following settings are
relevant and shall be setup to match the ECU performance and RAM resource availability.
2015, Vector Informatik GmbH
Version: 3.09.00
39 / 158
based on template version 5.1.0

Technical Reference CANdesc
Figure 6-14 GENy CANdesc scheduler parameters
Attribute Name Availability Value Values Description Type The default value is
written in bold
Maximum Count of
Only if the periodic Integer
5 The maximum number of items
Scheduled Items
data reading
1..255
that are sent periodically.
service is available
You can only request at most this
in the ECU
number of periodic DIDs,
configuration.
independently per scheduling rate.
Example:
2015, Vector Informatik GmbH
Version: 3.09.00
40 / 158
based on template version 5.1.0
Technical Reference CANdesc
Attribute Name Availability Value Values Description Type The default value is
written in bold
If set up 5 items for scheduling,
CANdesc will be able to schedule
at most 5 items at fast, 5 items at
slow and 5 items at medium rate.
Note: If the scheduler size exceeds
the total number of available
periodic DIDs, CANdesc will
automatically reduce the size to
the lowest value.
Fast/Medium/Slow
Only if the periodic Integer
OEM Specifies the timings of each
Scheduling Rate
data reading
dependent scheduling rate that the ECU
[ms]
service is available
1..65535
supports.
in the ECU
configuration.
2015, Vector Informatik GmbH
Version: 3.09.00
41 / 158
based on template version 5.1.0


Technical Reference CANdesc
7 CANdescBasic Configuration in GENy As already stated in
6 CANdesc Configuration in GENy since version 6.00.00, the
CANdesc configuration in GENy has been changed. Both CANdesc and CANdescBasic
variants share the same GUI and settings representation in GENy. Due to the reduced
feature set in CANdescBasic, its GENy GUI provides you correspondingly a reduced
configuration option set, covering all of the CANdescBasic requirements.
7.1 Global CANdescBasic Settings CANdescBasic shares the same global settings as the CANdesc variant (please refer to
chapte
r 6.2.1 Global CANdesc Settings).
Info
CANdescBasic does not support any of the multi identity modes!
7.2 Service Specific Settings In CANdescBasic, you don’t have any more an external diagnostic specification document
that shall be imported (like a CDD file). In your software delivery, there is already a
prepared diagnostic configuration template that fulfills the concrete OEM and its diagnostic
protocol requirements.
Info
In CANdescBasic versions, prior 6.00.00, it was possible to import information, out of a
CDD file, whether a service Id is supported or not-supported and any new sessions. In
CANdesc 6.00.00 and newer this feature is temporarily disabled, but you still can
manually configure these changes.
Since CANdescBasic provides only a Sid view over the diagnostic services, its service specific configuration is performed
primarily within the service overview grid in GENy (please refer to chapter
0 Service Specific Settings CANdescBasic also provides a built in support for some of the diagnostic services like
CANdesc, but its scope is reduced (due to lack of enough service definition information)
only to the most important for diagnostic communication services (e.g.
DiagnosticSessionControl, TesterPresent, etc.). You will recognize these services in GENy
as described in chapte
r 6.2.2.2 Predefined (implemented) Services in CANdesc. 2015, Vector Informatik GmbH
Version: 3.09.00
42 / 158
based on template version 5.1.0


Technical Reference CANdesc
7.3 Timing Settings The configuration aspect of the CANdescBasic timings settings is the same as described
in 6.2.3 Timing Settings, with the difference, that here there is no CDD file but a predefined
template.
7.4 Diagnostic State Configuration CANdescBasic has a built in support only for the diagnostic session states. All other states
like SecurityAccess and ECU specific service execution conditions shall be implemented
by the application.
The supplied CANdescBasic template already includes all mandatory session, specified by
the concrete OEM. If some additional sessions needed, you can add them in GENy as
shown below:
Figure 7-1 CANdescBasic add a user session
Info
For any session added by you (user sessions), GENy automatically creates all session
transitions, required by the concrete diagnostic protocol (e.g. UDS, KWP2000).
Examples:
Service 0x10:
<AllExistingSessions>-><NewSsession>,
<NewSession>-><NewSession>
Service 0x20:
<NewSession>-><DefaultSession>
2015, Vector Informatik GmbH
Version: 3.09.00
43 / 158
based on template version 5.1.0


Technical Reference CANdesc
Caution
The allowed session Ids are protocol dependent. For example: on UDS you can not
specify user sessions with Ids greater than 0x7F. On KWP2000 any value is acceptable
for session Id.
The session Id must be a unique value among all sessions, supported by your ECU.
For the user defined session, you can any time change their name, session or completely
remove them:
Figure 7-2 CANdescBasic change user session name, id or completely delete user session
Once a user session has been added, you can configure for each service whether it shall
be supported or not in the new session. You can do this configuration either on the service
overview grid, or if there are some service that have sub-services, for each sub-service.
The pictures below show each of the service level configuration views.
2015, Vector Informatik GmbH
Version: 3.09.00
44 / 158
based on template version 5.1.0


Technical Reference CANdesc
Figure 7-3 CANdescBasic session configuration at service overview
Figure 7-4 CANdescBasic session configuration at service Id level
2015, Vector Informatik GmbH
Version: 3.09.00
45 / 158
based on template version 5.1.0

Technical Reference CANdesc
Figure 7-5 CANdescBasic session configuration at sub-service level
2015, Vector Informatik GmbH
Version: 3.09.00
46 / 158
based on template version 5.1.0

Technical Reference CANdesc
8 Multi Identity Support CANdesc allows you to use multiple diagnostic configuration sets – a use case where the
ECU always communicates over the same connection, but shall implement different
functionality depending on some hardware (jumper) setting.
All supported configuration sets are described in the following chapters.
Info
Please note:
The multi identity feature of CANdesc is:
firstly supported in CANdesc 6.00.00;
not supported at all in the CANdescBasic variant.
8.1 Single Identity Mode CANdesc has a static configuration set – once all services and communication
connections are configured, and the program code is flashed into the ECU there are no
more configuration changes possible.
8.1.1.1 Configuration in CANdela You need just to prepare the corresponding CDD variant for your ECU configuration in
CANdelaStudio.
8.1.1.2 Configuration in GENy Import the CDD file and the corresponding variant in GENy (please refer to
chapter 6.2
Step Two – ECU Diagnostic Configuration in GENy for details).
8.2 VSG Mode The VSG mode is a special multi identity mode, which has the following characteristics:
> Allows to support multiple diagnostic configuration variants – each variant reflects a
VSG from the imported CDD file, and additionally there is a base variant that contains
all services that does not belong to any VSG.
> One or several configuration variants can be simultaneously activated during the ECU
initialization. The base variant is always active.
2015, Vector Informatik GmbH
Version: 3.09.00
47 / 158
based on template version 5.1.0






Technical Reference CANdesc
CANdesc
APPL
CANdesc
CANdesc
DIAG CFG
TP
> Figure 8-1 CANdesc multi identity mode
CANdesc will be initialized with the base variant at ECU start up sequence. If required,
additional variant(s) can be activated by the application (please refer to chapter
12.6.2
Multi Variant Configuration Functions for more information about the variant initialization).
8.2.1 Implementation Limitations In order to generate the correct NRC for a requested service Id (e.g. 0x7F
(ServiceNotSupprtedInActiveSession), CANdesc considers all of its sub-services
diagnostic session specific execution precondition and calculates a diagnostic session
filter for the SID. In case of a multi-identity such a calculation shall be made for all of the
diagnostic configuration variants, which will cost a lot of ROM resources.
In order to keep CANdesc ROM resources as low as possible the service Id specific
session filtering is created considering the superset of all sub-services it contains,
independently of their configuration affiliation. Depending on the active configuration set in
the ECU, this limitation can lead to the following effect:
A requested service will be responded with the NRC 0x12 (SubfunctionNotSupported) or
0x31(requestOutOfRange), depending on if it has a sub-function or not, instead of the
NRC 0x7F. Such a configuration could be for example:
Service 0x22 (ReadDataByIdentifier) supports only two DIDs:
0xF100 - supported only in the default diagnostic sessions and available only in variant 1;
0xF101 – supported only in a non-default session and available only in variant 2.
CANdesc will summarize in this case, that service 0x22 is allowed in any diagnostic
session since there is at least one DID supported in at least one of each session.
Now let’s assume the ECU is powered up with active variant 2. If the client sends a
request 0x22 0xF100 while in the default diagnostic session, CANdesc will respond with
2015, Vector Informatik GmbH
Version: 3.09.00
48 / 158
based on template version 5.1.0

Technical Reference CANdesc
the NRC 0x31 (DID not supported), instead of the 0x7F (none of the DIDs in the active
configuration is executable in the default session -> the service Id itself is not executable in
the session -> NRC 0x7F would be expected).
8.2.2 Configuration in CANdela > If multiple diagnostic configuration sets shall be selectable in CANdesc, you will need
a CDD with several VSGs where each describes a diagnostic configuration set.
Caution
CANdesc supports the multiple diagnostic configurations only on service/sub-service
availability level. Therefore the following limitations must be considered while creating
the separate CDD files resp. CANdela variants for CANdesc:
> A service can be completely deactivated within a VSG;
> A sub-service (e.g. DID, sub-function, etc.) can be completely deactivated within a
VSG;
> If a service exist in multiple VSGs, then it must have exactly the same properties
> Execution pre-conditions (e.g. diagnostic session, security access, etc.)
> Support of SPRMIB
> Addressing mode (physical/function)
> Response behavior (response on physical/function request)
> If a sub-service exist in multiple VSGs, then it must have exactly the same
properties
> Execution pre-conditions (e.g. diagnostic session, security access, etc.), resp.
trigger of state transitions.
> Addressing mode (physical/function)
> Response behavior (response on physical/function request)
> Protocol information semantic (sub-function, identifier, etc.)
> Request resp. response content must be identical – same data structure, data
types, and constant value (if any available)
> Service 0x31 (RoutineControlByIdentifier) specifics
> The multi-identity varying is allowed only on RID level. If a RID is supported in
multiple variants, then the sub-functions supported by this RID must be the same
(i.e. it is not allowed to have one variant with only “start” sub-function and one with
“start and stop” for the one and same RID).
> Service 0x2F (IoControlByIdentifier) specifics
> The multi-identity varying is allowed only on DID level. If a DID is supported in
multiple variants, then the control options supported by this DID must be the same
(i.e. it is not allowed to have one variant with only “ShortTermAdjustment” and one
with “ShortTerm-Adjustment and ReturnControlToEcu” for the one and same DID).
> > If at least one of the above requirements is not fulfilled, the variant that violates the
rule will not be imported.
> 2015, Vector Informatik GmbH
Version: 3.09.00
49 / 158
based on template version 5.1.0

Technical Reference CANdesc
8.2.3 Configuration in CANdela Please follow the steps below on how to configure VSG in CANdelaStudio.
1.
2. Defining all available VSGs for the concrete ECU.
3. In CANdelaStudio, select the Vehichle System Groups view and add all necessary
VSGs into the VSG pool.
Figure 8-2 Defining VSGs in CANdelaStudio
The name of the created VSG will be used later by CANdesc for the diagnostic
configuration constants that the CANdesc application shall use during the configuration
activation phase (please refer to chapte
r 12.6.2 Multi Variant Configuration Functions). Once all of the required VSGs are created, you can start with the service to VSG
assignment.
4. Service to VSG assignment
5. Using CANdelaStudio you can assign any diagnostic instance to none, one or multiple
VSGs. Those services that do belong to a diagnostic instance without a VSG
assignment will be considered as services of the base variant (services that are always
available).
2015, Vector Informatik GmbH
Version: 3.09.00
50 / 158
based on template version 5.1.0

Technical Reference CANdesc
6.
Figure 8-3 Setting a VSG for service in CANdelaStudio
8.2.4 Configuration in GENy In order to put GENy into VSG mode, you have to select it on the CANdesc component
root. Please refer to the chapter
6.2.1 Global CANdesc Settings for details about the
variant selection option.
Now import the CDD file, containing the VSGs in GENy as described in chapte
r 6.1 Step
One – Importing an ECU Diagnostic Description. That is all.
8.3 Multi Identity Mode Multi Identy Mode is not supported by CANdesc.
2015, Vector Informatik GmbH
Version: 3.09.00
51 / 158
based on template version 5.1.0

Technical Reference CANdesc
9 Diagnostic Service Implementation Specifics 9.1 Clear Diagnostic Information (SID $14) (UDS2012) Caution
This section does not apply to all ECU configurations. It is only applied in special cases
where clear diagnostic information is supported!
The sevice ClearDiagnosticInformation is used by the client to clear diagnostic information
in a memory of one or multiple server(s).
9.1.1 Tasks performed by CANdesc To a certain degree CANdesc validates the request. The validation of service-level states
(session, security and user states) is performed by CANdesc before CANdesc calls the
application callback.
9.1.2 Task to be performed by the Application The application has to verify the length of the request and also has to check if the passed-
on groupOfDTC parameter is valid.
9.2 ReadDTCInformation (SID $19) 9.2.1 Limitations of the service When CANdesc is used with an AR3 DEM from Vector, some sub-functions of service
0x19 are implemented internally. The DEM generates lists of the available Snapshot and
ExtendedData records which are used by CANdesc for iteration. In case the services are
internally implemented, the maximum amount of Snapshot records and Extended Data
records supported by CANdesc is limited to 240 records each.
9.3 ReadDataByIdentifier (SID $22) This service has the purpose to read some predefined data records (PID). Each PID has a
concrete data structure which is designed by CANdelaStudio.
As the standard case the request contains a single PID. This results in a single response
containing the data structure of the record.
2015, Vector Informatik GmbH
Version: 3.09.00
52 / 158
based on template version 5.1.0
Technical Reference CANdesc
Single PIDSing mode le PID( mode well knokn w case ca) se examplexe for Pe fID or P$1ID 2$1 34Tester‘s reque
Te
st:
ster‘s reque
$22 $12 $34
ECU‘s response:
ECU‘s respon
$62 $12 $34 Data bl
Da
ock
The UDS allows to request multiple PIDs in a single request. This results is also a single
response including the data structure of each requested PID.
MultipMulletip PID mod PIe exaD modmple fore exa mple for PIDsPID : $1234, $1$ABCD$ATester‘s reque
Te
st:
ster‘s reque
$22 $12 $34 $AB
$A $CD
ECU‘s response:
ECU‘s respon
$62 $12 $34 Data bl
Da
ock $AB
$A $CD
Data bl
Da
ock
CANdesc will hide this multiple PID processing from the application. To do that some minor
limitations in the interface has to be made (see chapte
r 9.3.2 Single PID mode). To show
the differences, we discuss first the standard case. In the standard case there is no
multiple PID processing possible. The second chapter
(9.3.3 Multiple PID mode) is
showing the multiple PID processing.
Which mode is used depends on the configuration (typically the OEM).
2015, Vector Informatik GmbH
Version: 3.09.00
53 / 158
based on template version 5.1.0
Technical Reference CANdesc
9.3.1 Limitations of the service Session management
This service contains no sub-function identifier which means the global state group
“session” may not be selected as a “relevant group” for any instance of this service. If
there is a need for a PID to be rejected under a certain session, all PIDs must follow this
rule and be specified to be rejected for this session. As a result the whole SID $22 will be
rejected for this session. This behavior is harmonized with the UDS protocol specification,
which allows service identifiers to be rejected in a session but no parameter identifiers.
2015, Vector Informatik GmbH
Version: 3.09.00
54 / 158
based on template version 5.1.0
Technical Reference CANdesc
9.3.2 Single PID mode The Single PID mode is configured automatically, if the number of PIDs that can be
requested at the same time, is limited to one PID. If more than one PID is requested, the
request will be rejected with ‘RequestOutOfRange’ (NRC $31).
If the multiple PID mode of CANdesc is deactivated, the service $22 will be executed and
processed like any other diagnostic service without any additional specifics or limitations.
9.3.2.1 Sending a positive response using linear buffer access Tester
CANdesc
Application
Check all states if the
SId[$22],Pid[$xxxx]
"read PID" service can
StateGroupsCheck for Pid
be executed.
If available execute the pre-handler and
ApplDescPreReadDataById_xxxx
check if the application rejected the service.
ApplDescReadDataById_xxxx
Execute the main-handler
Write data (pMsgContext->resData)
to fill the response data.
Set total response data length
(pMsgContext->resDataLen = N)
DescProcessingDone()
RSid[$62], PID[$xxxx], Data[N]
The positive response transmission will be
initiated after the DescProcessingDone
gets called.
Figure 9-1: Linearly written positive response on single PID request
2015, Vector Informatik GmbH
Version: 3.09.00
55 / 158
based on template version 5.1.0
Technical Reference CANdesc
9.3.2.2 Sending a positive response using ring buffer access Tester
CANdesc
Application
Check all states if the
SId[$22],Pid[$xxxx]
"read PID" service may
StateGroupsCheck for Pid
be executed.
If available execute the pre-handler and check if
ApplDescPreReadDataById_xxxx
the application rejected the service.
Execute the main-handler
ApplDescReadDataById_xxxx
to fill the response data.
Set total response data length
(pMsgContext->resDataLen = N)
DescRingBufferStart()
Write data (DescRingBufferWrite())
FF (RSid[$62], PID[$xxxx], Data[3])
The positive response transmission will be initiated after
the DescRingBufferStart gets called and there are at
least 7 bytes ready to be transmitted (i.e. 3 data bytes).
Write data (DescRingBufferWrite())
CF(Data[N-3])
Figure 9-2: “On the fly” response data writing.
2015, Vector Informatik GmbH
Version: 3.09.00
56 / 158
based on template version 5.1.0
Technical Reference CANdesc
9.3.2.3 Sending a negative response Due to the fact that the negative response handling has changed in the multiple PID mode,
we recommend to do the same handling in the Single PID mode, too. Please refer the
chapte
r 9.3.3.2 “Ring buffer active configuration” for the recommended negative response
handling.
Tester
CANdesc
Application
Check all states if the
SId[$22],Pid[$xxxx]
"read PID" service can
StateGroupsCheck for Pid
be executed.
If available execute the pre-handler and
check if the application rejected the service.
ApplDescPreReadDataById_xxxx
Execute the main-handler
ApplDescReadDataById_xxxx
to fill the response data.
DescSetNegresponse(errorCode)
The main-handler still can
register any errors.
DescProcessingDone()
RSid[$7F], Sid[$22], ErrorCode[errorCode]
The negative response transmission will be
initiated after the DescProcessingDone
gets called.
Figure 9-3: Negative response on single PID
9.3.3 Multiple PID mode The Multiple PID mode is configured automatically if the number of PIDs, that can be
requested at the same time, is greater than one. If more than this predetermined number
of PIDs is requested, the request will be rejected with ‘RequestOutOfRange’ (NRC $31).
In this configuration some minor limitations must be taken into account while using the
CANdesc interfaces.
For the service “ReadDataByIdentifier” the ring-buffer feature can be used. Depending on
the usage of this feature, there are two main use cases for the multiple PID mode.:
2015, Vector Informatik GmbH
Version: 3.09.00
57 / 158
based on template version 5.1.0
Technical Reference CANdesc
9.3.3.1 Pure linear buffer configuration The ring-buffer feature is deactivated in general.
If the system doesn’t use any ring buffer access for filling the response, the PID pipeline is
still quite simple and therefore with less limitations to the CANdesc API usage and
application performance.
9.3.3.1.1 Sending a positive response Tester
CANdesc
Application
SId[$22],Pid0[$xxxx],Pid1[$yyyy]
Before the requested PIDs will be processed, check
StateGroupsCheck for PID0[$xxxx]
all PIDs':
1. States (may be executed)
2. Pre-handlers.
ApplDescPreReadDataById_xxxx
StateGroupsCheck for PID1[$yyyy]
ApplDescPreReadDataById_yyyy
ApplDescReadDataById_xxxx
Execute the first PID's
main-handler to fill the response
data.
Write data (pMsgContext->resData)
Set total response data length
(pMsgContext->resDataLen = N)
Once the service execution of
the current PID has been
accomplished...
DescProcessingDone()
...execute the next
queued one.
ApplDescReadDataById_yyyy
Write data (pMsgContext->resData)
Set total response data length
(pMsgContext->resDataLen = M)
DescProcessingDone()
FF (RSid[$62], PID0[$xxxx], Data[3])
CF[i](Data[N-3],PID1[$yyyy]Data[M)
The positive response transmission will be
initiated after all PIDs have called
DescProcessingDone and all the data ...
Figure 9-4: Linearly written positive response on multiple PIDs (global ring buffer option is off)
2015, Vector Informatik GmbH
Version: 3.09.00
58 / 158
based on template version 5.1.0
Technical Reference CANdesc
9.3.3.1.2 Sending a negative response This example depicts the case where from two requested PIDs the first one may not be
accessible and rejects the service execution.
Tester
CANdesc
Application
Before requested PIDs will be processed check all
SId[$22],Pid0[$xxxx],Pid1[$yyyy]
PIDs':
StateGroupsCheck for PID0[$xxxx]
1. States (may be executed)
2. Pre-handlers.
ApplDescPreReadDataById_xxxx
StateGroupsCheck for PID1[$yyyy]
ApplDescPreReadDataById_yyyy
ApplDescReadDataById_xxxx
Execute the first PID's
main-handler to fill the response
data.
DescSetNegResponse(errorCode)
Once the service execution of
the current PID has been
accomplished...
DescProcessingDone()
Skip further processing
of the list
RSid[$7F], Sid[$22], ErrorCode[errorCode]
The second PID's
Main-handler will not be
executed.
...stops the further
processing a...
Figure 9-5: Negative response on multiple PIDs (global ring buffer option is off)
9.3.3.2 Ring buffer active configuration Attention: The Ring-Buffer in ‘Multiple PID‘ services can be first-time used since CANdesc
version 2.13.00
Different concepts for the buffer handling were discussed while development. Two
solutions with different pros and cons are discussed here:
Multiple buffer
Normally each service handler (MainHandler routine) has the whole diagnostic buffer
available (apart from the protocol header bytes hidden by CANdesc). Based on this logic
the service $22 using PID pipelining has the same tasks as the normal service processor:
executing a PID handler and provide him the whole diagnostic buffer for response data.
This will hide the whole process and makes the application’s life easier (no exceptions for
the implementation). To realize this concept means to provide a separate diagnostic buffer
for each PID which size is the same as the main one (configured by GENtool). This is a
fast and quite simple solution but requires too much RAM to be reserved for only the case
that sometimes the testers would like to use the maximum capacity of the ECU (i.e.
requests as many PIDs as possible for this ECU in a single request).
Pros: less ROM usage
2015, Vector Informatik GmbH
Version: 3.09.00
59 / 158
based on template version 5.1.0
Technical Reference CANdesc
Cons: very high RAM usage
virtual multiple buffer
This concept is more generically designed and will not have additional ROM overhead if
the pipeline size will be increased. An intelligent buffer concept gives the application the
whole size of the buffer for each MainHandler call.
Once the whole data for the current PID has been written, the data supplement will stop
(because the next PID handler will not be called). The transmission in the transport layer is
started and some time later it runs into buffer under-run. This ‘signal’ is used to call the
next PID MainHandler. This MainHandler has to provide his data very quick. Otherwise the
response transmission will stop (due to a continuously buffer under-run).
Pros: less RAM usage (practically independent of the maximum list size).
Cons: moderate ROM overhead / the response data must be composed very quickly.
The virtual multiple buffer concept is the implemented solution. The application can choose
for each PID separately to write the data linearly or by using the ring buffer.
performance requirements
The application has performance requirements:
If linear access has been chosen, the whole response data of each MainHandler must be
filled within the lower duration of the P2 time and the TP confirmation timeout. Normally the
P2 time is shorter than the transport layers confirmation timeout so just take into account
that each Main-Handler must be able to fill its response data within a time far shorter than
the P2 time.
If ring buffer access has been chosen, the application has to call the
“DescRingBufferWrite” fast enough to keep TP from confirmation timeout.
Negative response on PID
The negative response handling
is changed in the multiple PID mode! This affects all
protocol-services with a activated ‘May be combined’ property. The UDS specification
encloses only the SIDs: $22 and $2A. For all other services the negative response
handling is not changed!
If the application has to reject a request (e.g. ignition key check) it has to do that in the
PreHandler. The application is
not allowed to call “DescSetNegResponse()” to send a
negative response in any MainHandler.
This limitation is based on the concept to check all reject conditions in PreHandlers before
starting the transmission. This is necessary because after CANdesc has executed the first
MainHandler (which starts the positive response transmission) there will be no chance to
send a negative response.
The usage of the concept: CANdesc starts to call all PreHandlers of this multiple PID
request. If no negative response is set, CANdesc will start to call the corresponding
MainHandlers. Within the first call of DescProcessingDone() the transmission is initiated.
Note (for version 3.02.00 of CANdesc and above): 2015, Vector Informatik GmbH
Version: 3.09.00
60 / 158
based on template version 5.1.0
Technical Reference CANdesc
In case the application sets an error code during the main-handler execution in non-debug
(released) version of the component, depending on the situation will lead to:
For service $22:
First DID of the list main-handler: sending a negative response to service $22;
Second or any of the succeeding DIDs in the list: transmission interruption.
For service $2A:
Ignoring the scheduled response.
9.3.3.2.1 Sending a positive response Tester
CANdesc
Application
SId[$22],Pid0[$xxxx],Pid1[$yyyy]
Before requested PIDs will be processed check all
StateGroupsCheck for PID0[$xxxx]
PIDs':
1. States (may be executed)
ApplDescPreReadDataById_xxxx
2. Pre-handlers.
StateGroupsCheck for PID1[$yyyy]
ApplDescPreReadDataById_yyyy
ApplDescReadDataById_xxxx
Execute the first PID's
main-handler to fill the response
data.
Write data (pMsgContext->resData)
Set total response data length
(pMsgContext->resDataLen = N)
DescProcessingDone()
FF (RSid[$62], PID0[$xxxx], Data[3])
With the first called
DescProcessingDone() starts
the response transmission.
CF[i](Data[N-3])
Once the whole data of the current PID has
been sent the next PID main-handler will be
ApplDescReadDataById_yyyy
called to supply the response data.
Write data (pMsgContext->resData)
CF[j](Data[N-k],PID1[$yyyy]Data[m])
Set total response data length
(pMsgContext->resDataLen = M)
DescProcessingDone()
CF[l](Data[M-m])
2015, Vector Informatik GmbH
Version: 3.09.00
61 / 158
based on template version 5.1.0
Technical Reference CANdesc
Figure 9-6: Linearly written response data on multiple PIDs (global ring buffer option is on)
9.3.3.2.2 Sending a negative response Tester
CANdesc
Application
SId[$22],Pid0[$xxxx],Pid1[$yyyy]
Before requested PIDs will be processed check all
StateGroupsCheck for PID0[$xxxx]
PIDs':
1. States (may be executed)
2. Pre-handlers.
ApplDescPreReadDataById_xxxx
StateGroupsCheck for PID1[$yyyy]
ApplDescPreReadDataById_yyyy
DescSetNegResponse(errorCode)
If error has been set - no
main-hadnler processing will
follow.
RSid[$7F], Sid[$22], ErrorCode[errorCode]
Send immediately
negative response.
Figure 9-7: Negative response on multiple PIDs (global ring buffer option is on)
2015, Vector Informatik GmbH
Version: 3.09.00
62 / 158
based on template version 5.1.0
Technical Reference CANdesc
9.3.3.2.3 PostHandler execution rule All PostHandlers are executed after the finished response transmission (like a normal
PostHandler).
Independent of the ring-buffer option setting (enabled or disabled), the execution of the
service $22 PostHandler(s) has the following rule which has to be taken into account:
calling the Post-Handler of a specific PID means: either the PreHandler of this PID
has been previously called or its MainHandler.
The following sequence chart depicts this:
Tester
CANdesc
Application
SId[$22],Pid0[$xxxx],Pid1[$yyyy],
Before requested PIDs will be processted check all
Pid2[$zzzz]
StateGroupsCheck for PID0[$xxxx]
PIDs':
1. States (may be executed)
2. Pre-handlers.
ApplDescPreReadDataById_xxxx
PID0, PID1and PID2 have all
post-handlers configured.
StateGroupsCheck for PID1[$yyyy]
PID1 has no pre-handler
cofigured.
StateGroupsCheck for PID2[$zzzz]
ApplDescPreReadDataById_zzzz
DescSetNegResponse(errorCode)
If error has been set - no
main-hadnler processing will
follow.
RSid[$7F], Sid[$22], ErrorCode[errorCode]
Send immediately
negative response.
ApplDescPostReadDataById_xxxx
PID1 has a post-handler but since
the application doesn't know about
its reception - no post-handler will
ApplDescPostReadDataById_zzzz
be called.
Figure 9-8: Post-Handler execution sequence.
9.4 DynamicallyDefineDataIdentifier (SID $2C) (UDS) The DynamicallyDefineDataIdentifier service allows the client (tester) to dynamically define
in a server (ECU) a data identifier that can be read via the ReadDataByIdentifier service at
a later time.
The intention of this service is to provide the client with the ability to group one or more
data elements into a data superset that can be requested en masse via the
2015, Vector Informatik GmbH
Version: 3.09.00
63 / 158
based on template version 5.1.0
Technical Reference CANdesc
ReadDataByIdentifier or ReadDataByPeriodicIdentifier service. The data elements to be
grouped together can either be referenced by:
a source data identifier, a position and size or,
a memory address and a memory length, or,
a combination of the two methods listed above using multiple requests to define the single
data element. The dynamically defined dataIdentifier will then contain a concatenation of
the data parameter definitions.
The definition of the dynamically defined data identifier can either be done via a single
request message or via multiple request messages. This allows for the definition of a
single data element referencing source identifier(s) and memory addresses. The server
has to concatenate the definitions for the single data element. A redefinition of a
dynamically defined data identifier can be achieved by clearing the current definition and
start over with the new definition.
At last the dynamically defined data identifier consists of a list of (non-dynamically) defined
data identifiers and memory area ranges that can be used in any combination.
For more information, see /ISO 14229-1/
9.4.1 Feature set These are the supported subfunctions for service $2C (DynamicallyDefineDataIdentifier):
Subfunction Name Hex Value defineByIdentifier
01
defineByMemoryAddress
02
clearDynamicallyDefinedDataIdentifier 03
9.4.2 API Functions The reception of a Service $2C request will either delete a DynamicDataIdentifier (DDID)
or PeriodicDataIdentifier (PDID) by subfunction $03 or build a DDID/PDID by (several
times) using subfunction $01 and/or $02.
For subfunction $02 (defineByMemoryAddress) there is a new application callback
function (see chapte
r 12.6.13 “DynamicallyDefineDataIdentifier ($2C) (UDS) functions”). It
allows the application to permit or deny the extension of the DDID/PDID by accessing the
defined memory range. The callback function must check, if the requested memory area is
readable for the external Tester and if the current security state of the ECU permits the
extension of the DDID/PDID. See chapter
12.6.13.2 for the full set of checks to be
executed.
Please note that later, when reading the DDID by using service $22
(ReadDataByIdentifier), further (security) checks for each element of the DDID’s list are
executed to verify that e.g. the (then active) security state permits the
reading of the
memory area or DID. These checks (of Service $22 and $23) are done in the traditional
sequence of Pre-, Main- and PostHandler.
2015, Vector Informatik GmbH
Version: 3.09.00
64 / 158
based on template version 5.1.0
Technical Reference CANdesc
The reception of a Service $22 request starts a new context in CANdesc. Typically the
requested data can not be asked from the application by using one single callback function
but must be constructed sequentially by collecting data for each part of the DDID’s
definition list:
A requested basic source data identifier (DID) is asked of the application by the respective
callback (as for Service $22 request), the result data is stripped down to the defined
position and size
A memory address is read by its defined function (typically the same as used for a Service
$23 request) and the defined ‘size’ bytes are collected.
As recommended from /ISO 14229-1/ to prevent data consistency problems a recursive
definition of DDIDs is NOT supported.
The Service $22 response data is collected by splitting the service request into these basic
tasks, then running the well known internal functions that were defined for them, collect
their results and build up the Service $22 response. Therefore, each of the above tasks
starts a new context, executes the defined Pre-, Main- and Post-Handler where
Application-Callbacks get data, delivers its result and finally ends its context.
The recursive evaluation of DDIDs enforces the usage of MultiContext mode.
We would like to point out that the described operating sequence above is completely run
within CANdesc and totally transparent for the application except for the additional API
callback function. Using Service $2C or $2A switches CANdesc to MultiContext mode – if
your application isn’t prepared to support MultiContext mode (by using the defined macros)
you’ll get compiler errors about inconsistent argument lists.
9.4.3 Sequence Charts Service $2C – Define a DDID
The following picture exemplifies the sequence of defining a DDID by several call of
Service DynamicallyDefineDataIdentifier ($2C).
In our example the first Service $2C request defines the DDID $F300 to return two
independent
memory
areas.
For
both
areas
the
callback
function
ApplDescCheckDynDidMemoryArea() is triggered and in this example the application
permits both accesses.
The consecutive Service $2C request extends the DDID $F300 by (some fragments of) the
existing DID $F010. As the here executed PreHandler does not set a Negative Response
Code, CANdesc considers the extension of the DDID valid and enlarges the DDID
definition.
A third Service $2C request tries to extend the DDID $F300 once more by another memory
area. In our example the call fails, as the specified memory area ($0000) is not valid for
this ECU. The service is negative responded and the previous DDID specification is left
untouched.
2015, Vector Informatik GmbH
Version: 3.09.00
65 / 158
based on template version 5.1.0
Technical Reference CANdesc
sd Define a new DDID v ia Serv ice $2C requestTesterCANdescApplicationDefine DDID $F300 as
$2C 02 F300 12 ABCD04 FEDC05
4-byte memory block at
address $ABCD and
5-byte block at $FEDC
check for
ApplDescCheckDynDidMemoryArea
Addr. $ABCD,
memBlockOk
Size $04
check for
ApplDescCheckDynDidMemoryArea
Addr. $FEDC,
Size $05
memBlockOk
PosResponse ($6C 02)
$2C 01 F300 F010 ...
Extend the DDID $F300
PreHandler for DID F010
by using
existing DID $F010
No Neg. RCode
set --> success
PosResponse ($6C 01)
$2C 02 F300 12 000004
Further extention fails
due invalid address
value ($0000) in
ApplDescCheckDynDidMemoryArea
request
check for Addr.
memBlockInvAddress
$0000 fails!
NegResponse ($7F 2C 31)
Figure 9-9: Defining a DDID.
Service $22 – Read a DDID
The above defined DDID is now read by Service ReadDataByIdentifier ($22). Within
CANdesc the DDID is disassembled into its elements: One (virtual) request for the first
memory range, another request for the second memory range and finally a request for the
predefined DID $F010.
2015, Vector Informatik GmbH
Version: 3.09.00
66 / 158
based on template version 5.1.0

Technical Reference CANdesc
sd Read defined DDID v ia Serv ice $22 requestTesterCANdescApplicationRead DDID $F300 that
$22 F300
was defined as:
Addr ABCD, Size 04
$23 12 ABCD04
+ Addr FEDC, Size 05
+ DID F010, Pos .., Size ..
execute virtual
$23 request
PreHandler
MainHandler
PostHandler
$23 12 FEDC05
execute virtual
$23 request
PreHandler
MainHandler
PostHandler
$22 F010
execute virtual
$22 request ...
PreHandler
MainHandler
PostHandler
... and cut out the
required bytes
from the result
concatenate
the results
PosResponse ($62)
Figure 9-10: Reading a DDID.
Between
CANdesc and the
application the sequence looks same as if the tester would
have sent 3 requests: (1) ReadMemoryByAddress ($23) on first address range, (2)
ReadMemoryByAddress ($23) on second address range, and finally (3)
ReadDataByIdentifier ($22) on the DID $F010. Keep in mind: this is just a picture for the
succession of events/API-calls - these requests are not real, the messages are never seen
on the bus, the internal sequence is actually slightly different but for the application it looks
the same!
9.5 Read/Write Memory by Address (SID $23/$3D) (UDS) Caution
This chapter does not apply to all ECU configurations. Only in special cases the
memory access support will be available!
2015, Vector Informatik GmbH
Version: 3.09.00
67 / 158
based on template version 5.1.0









Technical Reference CANdesc
The services $23 (ReadMemoryByAddress) and $3D (WriteMemoryByAddress) are
handled uniformly in CANdesc.
Basically the memory by address requests look like this:
$23
FID
address length $3D
FID
address length data The application need not concern itself with the details how the address and length are
formatted. If a valid FID is recognized, CANdesc will extract the address and length
information from the request and call an appropriate application callback.
See also:
ApplDescReadMemoryByAddress
(12.6.14.1) ApplDescWriteMemoryByAddress
(12.6.14.2) 9.5.1 Tasks performed by CANdesc To a certain degree CANdesc validates the request.
The basic format checks and service level state validation – this means e.g. security and
session validation – are performed before calling the application callback.
Service level state validation means that the request will be denied if all diagnostic
instances of service $23 or $3D are not allowed in the current state.
In case of WriteMemoryByAddress the application has linear access to the whole data
block to write.
9.5.2 Task to be performed by the Application CANdesc currently does not provide state validation on format identifier level or memory
address / memory block level.
This means, that for example different memory addresses shall require different security
levels, the application will have to verify that the ECU currently is in an appropriate state to
access the requested memory area.
9.5.3 Repeated service calls The repeated service call feature is available for the memory access callbacks.
Because they have a different prototype than a normal main handler, the usual API
‘DescStartRepeatedServiceCall (see
12.6.8.1)’ can not be used with the memory access
callbacks.
Instead, a new API call ‘DescStartMemByAddrRepeatedCall (see
12.6.8.2)’ has been
added.
To abort the repeated service call, use the usual API.
2015, Vector Informatik GmbH
Version: 3.09.00
68 / 158
based on template version 5.1.0
Technical Reference CANdesc
10 Generic Processing Notifications If CANdesc UDS2012 is used, the feature “Generic Processing Notifications” is provided.
Upon activating this feature, CANdesc will notify the application when the processing of a
request starts and ends. Thereby, the notification mechanism is two-staged. On each
stage there are two application callbacks, one indication and one confirmation callback.
On the first stage “Manufacturer Notification Support”, CANdesc will notify the application
right before the processing of a fully received request starts, by calling the function
ApplDescManufacturerIndication(). When the processing of the request has been finished,
the response has been sent and all PostHandlers were called, CANdesc notifies the
application again by calling the function
ApplDescManufacturerConfirmation().
The application callbacks of the second stage “Supplier Notification Support” are named
accordingly
ApplDescSupplierIndication() and
ApplDescSupplierConfirmation(). The
indication callback is called by CANdesc after it has verified that the requested service is
supported in the active session, security state and user states. The confirmation callback
is also called after the response has been sent, and all PostHandlers were called, but right
before the call to
ApplDescManufacturerConfirmation(). Thus, the manufacturer and
supplier callbacks are called in a nested way
. Figure 3-1 illustrates the order of the
notification callbacks related to the processing of a service request.
ApplicationPrehandlerManufacturer MainhandlerSupplier IndicationConfirmationPosthandlerSupplier Manufacturer IndicationConfirmationCANdescCheck SID
… Check Format
Check Session/Security
t
Requestpositive Response
negative ResponseTester Figure 10-1 Call order of Manufacturer- and Supplier-Notficiation
2015, Vector Informatik GmbH
Version: 3.09.00
69 / 158
based on template version 5.1.0
Technical Reference CANdesc
10.1 Using dynamically defined data Identifier The Service DynamicallyDefineDataIdentifier allows the definition of data identifiers with
other data identifiers or memory areas. These DDIDs can be read via service
ReadDataByIdentifier. When reading a DDID, for each source element a virtual request is
processed by CANdesc to get the information for this source element from the
application(see chapte
r 9.4). Because CANdesc processes the virtual requests equal to
normal requests, the notification functions will not only be called for the $22 request
containing the DDID, but also for each virtual request. The application has to consider
these additional calls, in case a DDID is requested.
Figure 10-2 shows an example of reading a DDID with service $22.
sd Read defined DDID v ia Serv ice $22 request w ith Generic Processing NotificationsTester
CANdesc
Application
Read DDID $F300 that
$22 F300()
was defined as:
Addr ABCD, Size 04
Manufacturer Indication()
+ Addr FEDC, Size 05
Confirmation calls
+ DID F010, Pos .., Size ..
Supplier Indication()
execute virtual
for the request to
$23 request
read the DDID
$23 12 ABCD04()
Manufacturer Indication()
Nested confirmation
Supplier Indication()
calls for the virtual
request
PreHandler()
MainHandler()
PostHandler()
Supplier Confirmation()
Manufacturer Confirmation()
...
Process further
virtual requests
...
PosResponse ($62)
PostHandler()
Supplier Confirmation()
Manufacturer Confirmation()
Figure 10-2 Read out a DDID with generic processing notifications
2015, Vector Informatik GmbH
Version: 3.09.00
70 / 158
based on template version 5.1.0
Technical Reference CANdesc
11 Busy Repeat Responder Support (UDS2006 and UDS2012) Busy Repeat Responder is a feature, that allowes CANdesc to respond to incoming
requests during the processing of another request. Such parallel requests are properly
received and in the next task cycle of CANdesc responded negatively with NRC
BusyRepeatRequest (0x21).
Figure 11-1 illustrates the functionality of the Busy Repeat Responder mechanism. During
the processing of Request 1, Requests 2 and 3 from Tester 2 are responded negatively
with NRC BusyRepeatRequest. After the processing of request 1 has finished and a
positive response has been sent, Request 4 from Tester 2 can be processed properly.
sd BusyRepeatResponderTester 1
Tester 2
CANdesc
Request 1()
CANdesc has received a
request from Tester 1 and
starts the processing
Request 2()
Neg Response Busy()
Parallel requests from
another tester are responded
Request 3()
negatively with NRC
BusyRepeatRequest
Neg Response Busy()
Pos Response for Request 1()
After CANdesc has finished
Request 4()
the processing of the request
from Tester 1, Requests from
Tester 2 can be processed
Pos Response for Request 4()
again.
Figure 11-1 Illustration of the feature BusyRepeatResponder
Preconditions that must be fulfilled when using the feature Busy Repeat Responder:
> The TP must be an ISO TP from Vector with TP Class “Dynamic Normal Addressing
Multi TP” or “Dynamic Normal Fixed Addressing Multi TP”
> In the TP configuration the feature “Extended API – Overrun Reception” must be active
> In the TP configuration the number of Rx channels and Tx Channels must be > 1
> In case of Dynamic Normal Addressing Multi TP, a dispatcher needs to be
implemented in the application (for a detailed description see chapte
r 13.12) 2015, Vector Informatik GmbH
Version: 3.09.00
71 / 158
based on template version 5.1.0

Technical Reference CANdesc
> Restrictions when using the feature Busy Repeat Responder:
> Only physical parallel requests are responded negatively. Functional parallel requests
will NOT get a negative response.
11.1 Configuration in GENy To activate the feature Busy Repeat Responder use the setting in the CANdesc
component root (please refer to chapte
r 6.2.1 Global CANdesc Settings). Furthermore, the feature requires additional configuration in the TP component. The
feature “Extended API – Overrun Reception” must be enabled. This setting is available in
the group “Advanced Configuration”. To be able to receive another request while one is
under processing, the “Number of Rx Channels” and “Number of Tx Channels” must be at
least two. The number of channels can be configured in the TP Connection Groups:
Figure 11-2 Example of the “Number of Rx(Tx) Channels” settings
In case of “Dynamic Normal Addressing Multi TP” a dispatcher needs to be implemented in
the application. The description of the GENy configuration to integrate the dispatcher is
described in chapter
13.12 …use “Dynamic Normal Addressing Multi TP” with multiple
tester. 2015, Vector Informatik GmbH
Version: 3.09.00
72 / 158
based on template version 5.1.0
Technical Reference CANdesc
12 CANdesc API 12.1 API Categories 12.1.1 Single Context
This API category is used if no parallel processing is necessary. This is typical for the ISO
14229 specification.
12.1.2 Multiple Context (only CANdesc)
This API category is used if parallel processing is necessary. This means not that
CANdesc can work with multiple instances, but only one functional request can be
processed parallel to a working physical request.
12.2 Data Types The following standard data types are used in this document:
vuint8 Represents 8 bit unsigned integer value.
vsint8 Represents 8 bit signed integer value.
vuint16 Represents 16 bit unsigned integer value.
vsint16 Represents 16 bit signed integer value.
vuint32 Represents 32 bit unsigned integer value.
vsint32 Represents 32 bit signed integer value.
Table 12-1: standard data types
Additional data types used in this document are described in the corresponding function
description.
12.3 Global Variables -
12.4 Constants 12.4.1 Component Version
The version of the CANdesc component consist of 3 parts in the following format:
MM.SS.BB,
Where:
> MM is the main version of the component,
> SS is the subversion of the component,
> BB is the bug-fix version of the component.
To get the current CANdesc version, the application could use the following shared data:
2015, Vector Informatik GmbH
Version: 3.09.00
73 / 158
based on template version 5.1.0
Technical Reference CANdesc
Name Type Description g_descMainVersion
BCD
Contains the main version part.
g_descSubVersion
BCD
Contains the subversion part.
g_descBugFixVersion
BCD
Contains the bug-fix version part.
Table 12-2: Version API data
Note: The version of the module is the same as the version of the generator’s DLL file.
12.5 Macros 12.5.1 Data exchange
The CANdesc provides a generic API for splitting a multi-byte (up to 4 bytes) variable to a
byte sequence with platform transparent access to each byte, and assembling a multi-byte
(up to 4 bytes) variable from a sequence of bytes.
12.5.1.1 Splitting 16 bit data
The following function could be used to get platform independent access to the
corresponding bytes of 16 bit data variable:
vuint8 DescGetHiByte(16BitData) vuint8 DescGetLoByte(16BitData) 12.5.1.2 Splitting 32 bit data
The following function could be used to get platform independent access to the
corresponding bytes of 32 bit data variable:
vuint8 DescGetHiHiByte(32BitData) vuint8 DescGetHiLoByte(32BitData) vuint8 DescGetLoHiByte(32BitData) vuint8 DescGetLoLoByte(32BitData) 12.5.1.3 Assembling 16 bit data
The application can create the 16 bit signal from a byte stream using the following API:
uint16 DescMake16Bit(hiByte, loByte)
where the
hiByte, loByte are the corresponding bytes for the returned 16 bit data.
2015, Vector Informatik GmbH
Version: 3.09.00
74 / 158
based on template version 5.1.0
Technical Reference CANdesc
12.5.1.4 Assembling 32 bit data
The application can create the 32 bit signal from a byte stream using the following API:
uint32 DescMake32Bit(HiHiByte, HiLoByte, LoHiByte, LoLoByte)
where the
HiHiByte, HiLoByte, LoHiByte, LoLoByte are the corresponding bytes for the
returned 32 bit dat
12.6 Functions 12.6.1 Administrative Functions 12.6.1.1 DescInitPowerOn() DescInitPowerOn Available since 2.00.00 Is Reentrant Is callback Prototype
Single Context
void
DescInitPowerOn (DescInitParam initParameter)
Multi Context
void
DescInitPowerOn (DescInitParam initParameter)
Parameter initParameter
Manufacturer specific type, please refer ‘CANdesc: OEM
specifics’ document
Return code -
-
Functional Description
PowerOn Initialization of the CANdesc.
This function has to be called once before all other functions of CANdesc after PowerOn.
Pre-conditions
Correctly initialized CAN-driver via
CanInitPowerOn() and TransportLayer via
TpInitPowerOn().
Call context
Background-loop level with global disabled interrupts
Particularities and Limitations > DescInitPowerOn (initParameter) must be called after
TpInitPowerOn() was called
(please refer to the /TPMC/ documentation), otherwise the reserved diagnostic
connection will be los
2015, Vector Informatik GmbH
Version: 3.09.00
75 / 158
based on template version 5.1.0
Technical Reference CANdesc
12.6.1.2 DescInit() DescInit Available since 2.00.00 Is Reentrant Is callback Prototype
Single Context
void
DescInit (DescInitParam initParameter)
Multi Context
void
DescInit (DescInitParam initParameter)
Parameter initParameter
Manufacturer specific type, please refer ‘CANdesc Part IV:
OEM specifics’ document
Return code -
-
Functional Description
Re-initialization of CANdesc.
This function can be called to re-initialize CANdesc (e.g. after WakeUp). All internal states
will be set to default, except the states in this initParameter (e.g. Session or
CommunicationControl).
Pre-conditions
CANdesc was once initialized via
DescInitPowerOn () Call context
Background-loop level with global disabled
12.6.1.3 DescTask() DescTask Available since 2.00.00 Is Reentrant Is callback Prototype
Single Context
void
DescTask (void)
Multi Context
void
DescTask (void)
2015, Vector Informatik GmbH
Version: 3.09.00
76 / 158
based on template version 5.1.0
Technical Reference CANdesc
Parameter -
-
Return code -
-
Functional Description
The function
DescTask() has to be called periodically (cycle time TDescCallCycle) by the
application.
Within the context of this function the interaction with the application is performed. In
addition the monitoring of the timings is done, therefore the accuracy of the timings
depends on the call cycle and on the accuracy of the calls.
Pre-conditions -
Call context
Background-loop level or OSEK-OS Task. The task should have a lower or equal priority
than all other interaction to the CANdesc component.
Particularities and Limitations > May not be called if the
DescStateTask() and
DescTimerTask() are called.
> 12.6.1.4 DescStateTask() DescStateTask Available since 4.00.00 Is Reentrant Is callback Prototype
Single Context
void
DescStateTask (void)
Multi Context
void
DescStateTask (void)
Parameter -
-
Return code -
-
2015, Vector Informatik GmbH
Version: 3.09.00
77 / 158
based on template version 5.1.0
Technical Reference CANdesc
Functional Description
Motivation: Using a single task function for timers and processing leads either to slow
processing or to faster timers which costs runtime for the ECU. The timers need very
stable cyclical call but the processing tasks may be done “as soon as possible” (i.e. using
OSEK to be assigned to lower priority task).
The function
DescStateTask() has to be called periodically by the application. It is not a
timer task – it has no specific time period. As smaller this tasks call period is, so faster will
be the service processing.
This task function will process received request and to control the transmission of the
responses. Depending on the ECU requirements it is recommended to call this task as
soon as possible to avoid delays of the response (e.g. dynamically defined DID,
scheduled data, etc.), but
take into account that within this task the corresponding
MainHandler will be executed too. Pre-conditions -
Call context
Background-loop level or OSEK-OS Task. The Task should have a lower or equal priority
than all other interaction to the CANdesc component.
Particularities and Limitations > May not be called if the
DescTask() is used (reentrancy is forbidden).
> 12.6.1.5 DescTimerTask() DescTimerTask Available since 4.00.00 Is Reentrant Is callback Prototype
Single Context
void
DescTimerTask (void)
Multi Context
void
DescTimerTask (void)
Parameter -
-
Return code -
-
2015, Vector Informatik GmbH
Version: 3.09.00
78 / 158
based on template version 5.1.0
Technical Reference CANdesc
Functional Description
Motivation: Using a single task function for timers and processing leads either to slow
processing or to faster timers which costs runtime for the ECU. The timers need very
stable cyclical call but the processing tasks may be done “as soon as possible” (i.e. using
OSEK to be assigned to lower priority task).
The function
DescTimerTask() has to be called periodically by the application in the
configured task period. It can be called as slow as possible to free run time resources.
Pre-conditions -
Call context
Background-loop level or OSEK-OS Task. The Task should have a lower or equal priority
than all other interaction to the CANdesc component.
Particularities and Limitations > May not be called if the
DescTask() is used. This will lead to either reentrancy
(consistency) problems or/and to timing issues.
> 12.6.1.6 DescGetActivityState() DescGetActivityState Available since 2.00.00 Is Reentrant Is callback Prototype
Single Context
DescContextActivity DescGetActivityState (void)
Multi Context
DescContextActivity DescGetActivityState (vuint8 iContext)
Parameter iContext
reference to the corresponding request context
2015, Vector Informatik GmbH
Version: 3.09.00
79 / 158
based on template version 5.1.0
Technical Reference CANdesc
Return code 1. kDescContextIdle
There is currently no request processing (even when
scheduler is active).
2. kDescContextActiveRxBegin
Currently request reception is active.
Reception finished, request will be processed.
3. kDescContextActiveRxEnd
The request was received, is under processing now
4. kDescContextActiveProcess
DescProcessingDone called waiting for data before
starting the transmission.
5. kDescContextActiveProcessEnd Ready for response transmission.
Transmission of the response is currently active.
6. kDescContextActiveTxReady
Transmission/processing ended. Post-processing will be
7. kDescContextActiveTx
performed.
8. kDescContextActivePostProcess
Functional Description
Motivation: Sometimes the knowledge about the presence of a tester is necessary. A typical
use-case is to avoid the ECU from going into sleep mode.
A non-default session indicates that a tester is present. But how can this be done, if the ECU is
in the default session?
Due to that fact the ECU application can call the function
DescGetActivityState() any time to
check if CANdesc has something to do or is in idle mode. This can be used e.g. to change the
state of the ECU sleep mode.
Note: The return value is bit coded and any senseful combination of the above mentioned
values is possible (e.g.
kDescContextActiveRxBegin |
kDescContextActivePostProcess).
Please check always with bit test (and operation) and not using the value comparison.
Pre-conditions -
Call context -
Particularities and Limitations > 12.6.2 Multi Variant Configuration Functions 12.6.2.1 DescInitConfigVariant() DescInitConfigVariant Available since 6.00.00 Is Reentrant Is callback Prototype
Single Context and Multi Context
void
DescInitConfigVariant (DescVariantMask varMask)
2015, Vector Informatik GmbH
Version: 3.09.00
80 / 158
based on template version 5.1.0
Technical Reference CANdesc
Parameter varMask
Contains the VSG(s) that shall be active additionally to the base
variant
Return code -
-
Functional Description
After CANdesc has been initialized via one of the APIs
DescInitPowerOn
or
DescInit;
the base variant will be only active (please refer to chapter
8 Multi Identity for more
details). If additionally other variants shall be activated, this API shall be called with a
parameter value that represents the variants (multiple variants can be OR-ed) that shall
be activated.
The variant values that shall be used for building the API parameter value are located in
the desc.h file. The naming convention is as follows:
kDescVariant<variant/VSG qualifier> Pre-conditions -Multi- variant (VSG) mode is activated for CANdesc.
Call context -
Particularities and Limitations > Shall not interrupt the DescTask function.
> Best place to call this API is immediately after the CANdesc initialization API-call while
the interrupts are still locked.
12.6.2.2 DescGetConfigVariant() DescGetConfigVariant Available since 6.00.00 Is Reentrant Is callback Prototype
Single Context and Multi Context
DescVariantMask
DescGetConfigVariant (void)
Parameter -
2015, Vector Informatik GmbH
Version: 3.09.00
81 / 158
based on template version 5.1.0
Technical Reference CANdesc
Return code Variant mask
Represents the bit-mapped value of the currently active variants
in the ECU.
Functional Description
This API returns the bit-mapped value of the currently active variants set in CANdesc.
The variant values that shall be used for checking the API return value are located in the
desc.h file. The naming convention is as follows:
kDescVariant<variant/VSG qualifier> Pre-conditions -Multi- variant (VSG) mode is activated for CANdesc.
Call context - This API can be called from any call-context.
Particularities and Limitations > -
12.6.3 Service Functions 12.6.3.1 DescSetNegResponse() DescSetNegResponse Available since 2.00.00 Is Reentrant Is callback Prototype
Single Context
void
DescSetNegResponse (DescNegResCode errorCode)
Multi Context
void
DescSetNegResponse (vuint8 iContext, DescNegResCode errorCode)
Parameter iContext
reference to the corresponding request context
errorCode
the
errorCode is the one of the provided error code constants
of CANdesc in the desc.h file with the following naming
convention:
kDescNrc<error name>.
Return code -
-
2015, Vector Informatik GmbH
Version: 3.09.00
82 / 158
based on template version 5.1.0
Technical Reference CANdesc
Functional Description
In the PreHandler or in the MainHandler function the application has the possibility of
forcing negative response with a certain negative response code for the current request
when it is necessary.
Pre-conditions -
Call context
Within a ‘Service PreHandler’ function and within or after a ‘Service MainHandler’ function
Particularities and Limitations > Once an error was set it can not be overwritten or reset.
> This function does not finish the processing of the request. It just sets a certain error
and after that the application must confirm that the request processing was completely
finished by calling DescProcessingDone().
12.6.3.2 DescProcessingDone() DescProcessingDone Available since 2.00.00 Is Reentrant Is callback Prototype
Single Context
void
DescProcessingDone (void)
Multi Context
void
DescProcessingDone (vuint8 iContext)
Parameter iContext
reference to the corresponding request context
Return code -
-
Functional Description
After completing the request execution the application must call the API function.
By calling this function, depending on the previous actions of the application the CANdesc
module will either send a response (positive/negative depending on the error state
machine) or no response will be send if the application/CANdesc decides that there must
be no response (please refer the Part III User Manual)
Pre-conditions -
Call context
Within or after a ‘Service MainHandler’ function
2015, Vector Informatik GmbH
Version: 3.09.00
83 / 158
based on template version 5.1.0
Technical Reference CANdesc
Particularities and Limitations
12.6.4 Service callback functions
In CANdesc 6 the naming convention of the service callback function has changed due to
standardization reasons. In
Table 12-3, the new naming convention can be found. Earlier
versions of CANdesc (< 6.0) used always Service-Qualifiers and Instance-Qualifiers from
the CDD file. Since CANdesc 6, for Service-Qualifiers always standardized names are
used, whereas for Instance-Qualifiers either a standardized name or the name from the
CDD file is used. The names of the service callback functions are based on the following
pattern:
ApplDesc[Pre|Post]<ServiceQualifier><DiagInstanceQualifier>
When migrating to CANdesc 6 the service callbacks have to be renamed according to the
new naming convention.
Service SubService Instance-Qualifier Service-Qualifier 0x01
Default
0x10
0x02
Programming
StartSession
0x03
Extended
0x01
Hard
0x02
KeyOffOn
0x11
0x03
Soft
EcuReset
0x04
EnableRapidShutDown
0x05
DisableRapidShutDown
0x14
None
DiagInfo
Clear
0x01
RNODTCBSM
ReadDtc
0x02
RDTCBSM
0x03
RDTCSSI
0x04
RDTCSSBDTC
0x05
RDTCSSBRN
0x06
RDTCEDRBDN
0x07
RNODTCBSMR
0x08
RDTCBSMR
0x19
0x09
RSIODTC
0x0A
RSUPDTC
0x0B
RFTFDTC
0x0C
RFCDTC
0x0D
RMRTFDTC
0x0E
RMRCDTC
0x0F
RMMDTCBSM
0x10
RMDEDRBDN
0x11
RNOMMDTCBSM
2015, Vector Informatik GmbH
Version: 3.09.00
84 / 158
based on template version 5.1.0
Technical Reference CANdesc
Service SubService Instance-Qualifier Service-Qualifier 0x12
RNOOBDDTCBSM
0x13
ROBDDTCBSM
0x14
RDTCFDC
0x15
RDTCWPS
0x16
RDTCRDIDBDN
0x41
RWWHOBDNDTCBMR
0x42
RWWHOBDDTCBMR
0x55
RWWHOBDDTCWPS
0x22
Any
Instance-Qualifier from CDD
ReadDid
0x23
None
MemoryByAddress
Read
0x24
Any
Instance-Qualifier from CDD
ReadScalingDid
Odd Id
GetSeed
0x27
Instance-Qualifier from CDD
Even Id
SendKey
0x00
EnableRxEnableTx
0x01
EnableRxDisableTx
0x28
CommCtrl
0x02
DisableRxEnableTx
0x03
DisableRxDisableTx
0x01
ReadDidSlow
0x02
ReadDidMed
0x2A
Instance-Qualifier from CDD
0x03
ReadDidFast
0x04
ReadDidStop
0x01
DynDefineByDid
0x2C
0x02
Instance-Qualifier from CDD
DynDefineByAddr
0x03
DynDefineClear
0x2E
Any
Instance-Qualifier from CDD
WriteDid
0x00
IoCtrlRetCtrlToEcu
0x01
IoCtrlRstToDefault
0x2F
Instance-Qualifier from CDD
0x02
IoCtrlFrzCurrState
0x03
IoCtrlShortTermAdj
0x01
RtnCtrlStart
0x31
0x02
Instance-Qualifier from CDD
RtnCtrlStop
0x03
RtnCtrlReqRes
0x34
None
RequestDownload
0x35
None
RequestUpload
0x36
None
TransferData
0x37
None
RequestTransferExit
0x3D
None
MemoryByAddress
Write
0x3E
0x00
TesterPresent
Send
0x84
None
SecuredDataTransmission
2015, Vector Informatik GmbH
Version: 3.09.00
85 / 158
based on template version 5.1.0
Technical Reference CANdesc
Service SubService Instance-Qualifier Service-Qualifier 0x01
Enable
0x85
ControlDtcSetting
0x02
Disable
0x00
Stop
0x01
OnDtcStatChg
0x02
OnTmrInt
0x03
OnChgOfDid
0x04
ReportActEv
0x05
Start
0x06
Clear
0x07
OnCompOfVal
0x86
Roe
0x40
StStop
0x41
StOnDtcStatChg
0x42
StOnTmrInt
0x43
StOnChgOfDid
0x44
StReportActEv
0x45
StStart
0x46
StClear
0x47
StOnCompOfVal
0x01
VerifyFixedBaudrate
0x87
0x02
VerifySpecificBaudrate
LinkControl
0x03
TransitionBaudrate
Table 12-3 Naming convention of service callback functions in CANdesc 6
12.6.4.1 Service PreHandler ApplDescPre<Service-Qualifier + Instance-Qualifier>> Available since 2.00.00 Is callback Prototype
Single Context
void
ApplDescPre<Service-Qualifier + Instance-Qualifier> (void)
Multi Context
void
ApplDescPre<Service-Qualifier + Instance-Qualifier> (vuint8 iContext)
Parameter iContext
the current request context location
Return code -
-
2015, Vector Informatik GmbH
Version: 3.09.00
86 / 158
based on template version 5.1.0
Technical Reference CANdesc
Functional Description
The PreHandler is executed before the Service MainHandler is called. In the PreHandler,
the application can hook any (especially application-specific) state validations. One
PreHandler implementation may be shared with different service instances (only
CANdesc).
To allow quite complex operations to take place, the application has access to the request
data using the context data structure (if given).
Pre-conditions
Must be configured to ‘User’ in attribute ‘PreHandlerSupport’’
Call context
From
DescTask() Particularities and Limitations
12.6.4.2 Service MainHandler ApplDesc<Service-Qualifier + Instance-Qualifier> Available since 2.00.00 Is callback Prototype
Single Context
void
ApplDesc<Service-Qualifier + Instance-Qualifier> (DescMsgContext* pMsgContext)
Multi Context
void
ApplDesc<Service-Qualifier + Instance-Qualifier> (DescMsgContext* pMsgContext)
Parameter pMsgContext
typedef struct
{
DescMsg reqData;
DescMsgLen reqDataLen;
DescMsg resData;
DescMsgLen resDataLen;
DescMsgAddInfo msgAddInfo;
vuint8 iContext;
t_descUsdtNetBus busInfo;
} DescMsgContext;
2015, Vector Informatik GmbH
Version: 3.09.00
87 / 158
based on template version 5.1.0
Technical Reference CANdesc
DescMsgAddInfo DescBitType reqType :2; /* 0x01: Phys 0x02: Func */
DescBitType resOnReq :2; /* 0x01: Phys 0x02: Func */
DescBitType suppPosRes:1; /* 0x00: No 0x01: Yes */
Read access
pMsgContext->reqData pointer to the first byte of the already extracted request data.
pMsgContext->reqDataLen length of the extracted request data.
pMsgContext->iContext the current request context location
(used only as a handle -
DO NOT MODIFY).
pMsgContext->msgAddInfo.reqType the current request addressing method. Could be either
‚kDescFuncReq’ or ‚kDescPhysReq’
(bitmapped).
pMsgContext->msgAddInfo.suppPosRes if set, no positive response will be sent. (UDS only).
pMsgContext->busInfo
the current request communication information (i.e. driver type (CAN,
MOST, FlexRay, etc.), addressing information, communication channel
number, tester address (if applicable) etc.
Write access
pMsgContext->resData
pointer to the first position where the response data can be written.
pMsgContext->resDataLen length of the written data.
pMsgContext->msgAddInfo.resOnReq can be used to disable the response transmission on the current
request. If set to ‘0’ no response will be transmitted. Physical and
function can be set separately (bitmapped).
Return code -
-
Functional Description
The MainHandler processes the service request.
Perform length validation for varying length information of request.
Disassemble any data received with the request telegram and process it,.
Assemble any data to be send with the response and update current response length.
Confirm that the processing is finished.
Pre-conditions
Must be configured to ‘User’ in attribute ‘MainHandlerSupport’
Call context
From
DescTask() Particularities and Limitations > If used as MainHandler for Protocol Services, the Protocol-Service-Qualifier is used
instead
2015, Vector Informatik GmbH
Version: 3.09.00
88 / 158
based on template version 5.1.0
Technical Reference CANdesc
12.6.4.3 Service PostHandler ApplDescPost<Service-Qualifier + Instance-Qualifier> Available since 2.00.00 Is callback Prototype
Single Context
void
ApplDescPost<Service-Qualifier + Instance-Qualifier> (vuint8 status)
Multi Context
void
ApplDescPost<Service-Qualifier + Instance-Qualifier> (vuint8 iContext,
vuint8 status)
Parameter iContext
the current request context location
status (bit-coded)
kDescPostHandlerStateOk The positive response was transmitted successfully
kDescPostHandlerStateNegResSent It was a negative response
kDescPostHandlerStateTxFailed A transmission error occurred
Return code -
-
Functional Description
Any state transition may not be performed before the current service is finished
completely (the last frame of the response is sent successfully).
The PostHandler is executed after a confirmation of the message transmission is received
and is designated for state adaptation – all other things are already done when the
PostHandler is called.
Pre-conditions
Must be configured to ‘User’ in attribute ‘PostHandlerSupport’
Call context
From
DescTask() Particularities and Limitations > If used as PostHandler for Protocol Services, the Protocol-Service-Qualifier is used
instead
> You can override the given name extension (Service-Qualifier + Instance-Qualifier) by
using the ‘PostHandlerOverrideName’.
12.6.5 Unknown (User) Service Handling
In some cases the ECU shall support a service which is not described in the common way
for CANdesc (by means of CANdelaStudio/GENtool). With a little bit more effort inside the
application than for the known services the ECU is still be able to support those unknown
services. The effort results from the fact that CANdesc knows nothing about this service
2015, Vector Informatik GmbH
Version: 3.09.00
89 / 158
based on template version 5.1.0
Technical Reference CANdesc
(e.g. session, security or other states described in the CDD configuring CANdesc,
addressing methods allowed for those services, etc.) and therefore the application must do
this work for each unknown service by itself. In fact for CANdesc there is only one
unknown service and it is up to the application to differentiate between multiple unknown
service(s).
Attention: This feature is available since version 2.11.00 of CANdesc(Basic).
12.6.5.1 How it works
If the feature “Unknown Services Acceptance” is enabled in the GENtool CANdesc uses
following handling:
if a service was not recognized by its SID, before the automatic negative response
transmission will be sent, the application will be called (see
12.6.5.2
ApplDescCheckUserService) to check this SID too. If it can not recognize it as a valid one
the usual negative response will be sent.
If the application has accepted the SID, then a special Unknown Service MainHandler will
be called (see
12.6.5.4 Unknown (User) Service MainHandler). If in GENtool “Unknown Services Post Handler Calls” is set, after the request processing
has been accomplished, a special Unknown service PostHandler will be called (see
12.6.5.5 Unknown (User) Service PostHandler). Note:
Since CANdesc doesn’t distinguish among unknown services, a special API was designed
to get the application the opportunity to dispatch among the SIDs (in MainHandler and in
the PostHandler).
The unknown services are processed on service id level which means the application shall
dispatch and do the whole format check of these requests. The state management shall be
performed bye application, too.
12.6.5.2 ApplDescCheckUserService() ApplDescCheckUserService Available since 2.11.00 Is callback Prototype
Single Context
vuint8
ApplDescCheckUserService (DescMsgItem sid)
Multi Context
vuint8
ApplDescCheckUserService (DescMsgItem sid)
Parameter sid
The service identifier which is currently under processing.
2015, Vector Informatik GmbH
Version: 3.09.00
90 / 158
based on template version 5.1.0
Technical Reference CANdesc
Return code kDescOk
Return this value if the service id is a “user defined” one.
Return this value if the service id is unknown for the application
kDescFailed
too.
Functional Description
The currently received request contains a service Id unkown to CANdesc. Within this
function the ECU application has to decide immediately if the SID is known or not.
Depending on the return value, CANdesc will process this request further or will reject it
by sending a negative response ‘ServiceNotSupported’.
Pre-conditions
The “Unknown Services Acceptance” option is enabled in the GENtool configuration.
Call context
From
DescTask() (in KWP diagnostics also from RxInterrupt).
Particularities and Limitations
12.6.5.3 DescGetServiceId() DescGetServiceId Available since 2.11.00 Is Reentrant Is callback Prototype
Single Context
DescMsgItem
DescGetServiceId (void)
Multi Context
DescMsgItem
DescGetServiceId (vuint8 iContext)
Parameter iContext
The current request context location
Return code DescMsgItem
The service id which is currently under processing.
Functional Description
Reports the service id of the currently processed unknown-service request.
Pre-conditions
The “Unknown Services Acceptance” option is enabled in the GENtool configuration.
Call context
From
DescTask() 2015, Vector Informatik GmbH
Version: 3.09.00
91 / 158
based on template version 5.1.0
Technical Reference CANdesc
Particularities and Limitations > This function may be called at any time within a diagnostic request life cycle starting at
the call of the MainHandler and ending by the PostHandler (if configured) or (if none
configured) by calling
DescProcessingDone 12.6.5.4 Unknown (User) Service MainHandler ApplDescUserServiceHandler Available since 2.11.00 Is callback Prototype
Single Context
void
ApplDescUserServiceHandler (DescMsgContext* pMsgContext)
Multi Context
void
ApplDescUserServiceHandler (DescMsgContext* pMsgContext)
Parameter pMsgContext
Please refer to sectio
n 12.6.4.2 Service MainHandler for details about
this parameter.
Read Access
pMsgContext->reqData pointer to the first byte after the service Id.
The other members of the parameter are described i
n 12.6.4.2 Service
MainHandler Write access
pMsgContext->resData pointer to the first byte after the response SID, where the data (incl. sub-
parameters) will be written.
The other members of the parameter are described i
n 12.6.4.2 Service
MainHandler Return code -
-
Functional Description
This MainHandler is called for all unknown service requests at service id level, so the
application has to do following:
Perform service id dispatching (if more than one user defined service shall be used).
Perform length validation for varying length information of request.
Perform parameter (if any) validation.
Disassemble any data received with the request telegram and process it.
Assemble any data to be send with the response and update current response length
Confirm that the processing is finished.
Pre-conditions
The “Unknown Services Acceptance” option was enabled in the GENtool configuration.
Call context
From
DescTask() 2015, Vector Informatik GmbH
Version: 3.09.00
92 / 158
based on template version 5.1.0
Technical Reference CANdesc
Particularities and Limitations > Please refer the sectio
n 12.6.4.2 Service MainHandler. > DescGetServiceId() may be called here to dispatch the SID of the currently processed
unknown service (please refer to
12.6.5.3 DescGetServiceId) 12.6.5.5 Unknown (User) Service PostHandler ApplDescPostUserServiceHandler Available since 2.11.00 Is callback Prototype
Single Context
void
ApplDescPostUserServiceHandler (vuint8 status)
Multi Context
void
ApplDescPostUserServiceHandler (vuint8 iContext, vuint8 status)
Parameter iContext, status
Please refer to section
12.6.4.3 Service PostHandler for
information.
Return code -
-
Functional Description
The functionality of the user service PostHandler is the same as the one of the normal
service PostHandler. Please refer to
12.6.4.3 Service PostHandler for more details.
Pre-conditions
The “Unknown Services Post Handler Calls” option was enabled in the GENtool
configuration.
CANdesc version >= 2.11.00
Call context
From
DescTask() Particularities and Limitations > Please refer to sectio
n 12.6.4.3 Service PostHandler for information.
> DescGetServiceId() may be called here to dispatch the SID of the currently post-
processed user service (please refer to
12.6.5.3 DescGetServiceId) 12.6.6 Session Handling 12.6.6.1 ApplDescCheckSessionTransition() ApplDescCheckSessionTransition Available since 2.00.00 Is callback 2015, Vector Informatik GmbH
Version: 3.09.00
93 / 158
based on template version 5.1.0
Technical Reference CANdesc
Prototype
Single Context
void
ApplDescCheckSessionTransition (DescStateGroup newState, DescStateGroup
formerState)
Multi Context
void
ApplDescCheckSessionTransition (vuint8 iContext, DescStateGroup newState,
DescStateGroup formerState)
Full message Context
void
ApplDescCheckSessionTransition (DescMsgContext* pMsgContext, DescStateGroup
newState, DescStateGroup formerState)
Parameter pMsgContext
Pointer to the current message context (refer t
o 12.6.4.2) iContext
the current request context location
newState
the CANdesc component has change to this session state
formerState
the CANdesc component has change from this session state
Return code -
-
Functional Description
This hook function will be called, while session request is received (SID $10). If the
application wants to discard this request, an error must be set (via
DescSetNegResponse() ).
The application always has to confirm this hook function via
DescSessionTransitionChecked().
Both above functions can be called also outside of the context of this function (e.g.
application task waiting for results form an I/O port). CANdesc will send RCR-RP
response as long as the application delays the confirmation for the session transition.
In some cases the application has to know whether the SPRMIB in the request was set or
not. Since this API call does not contain this information, a dedicated API in CANdesc
provides it:
DescIsSuppressPosResBitSet (). Pre-conditions
At least one DiagnosticSessionControl service must be configured to ‘OEM’ in attribute
‘MainHandlerSupport’
Call context
From
DescTask() 2015, Vector Informatik GmbH
Version: 3.09.00
94 / 158
based on template version 5.1.0
Technical Reference CANdesc
Particularities and Limitations > Call the API function
DescSessionTransitionChecked() to end the service processing
> 12.6.6.2 DescSessionTransitionChecked() DescSessionTransitionChecked Available since 2.00.00 Is Reentrant Is callback Prototype
Single Context
void
DescSessionTransitionChecked (void)
Multi Context
void
DescSessionTransitionChecked (vuint8 iContext)
Parameter iContext
the current request context location
Return code -
-
Functional Description
After the application has finished the processing in the hook function
ApplDescCheckSessionTransition() this function must be called.
Pre-conditions
At least one DiagnosticSessionControl service must be configured to ‘OEM’ in attribute
‘MainHandlerSupport’
Call context
Within or after a ‘
ApplDescCheckSessionTransition()’
function
Particularities and Limitations > If this function will be called late, the CANdesc component sends automatically the
RCR-RP responses
12.6.6.3 DescIsSuppressPosResBitSet () DescIsSuppressPosResBitSet Available since 5.07.14 Is Reentrant Is callback Prototype
Single Context
2015, Vector Informatik GmbH
Version: 3.09.00
95 / 158
based on template version 5.1.0
Technical Reference CANdesc
DescBool
DescIsSuppressPosResBitSet (void)
Multi Context
DescBool
DescIsSuppressPosResBitSet (vuint8 iContext)
Parameter iContext
the current request context location
Return code kDescTrue
The SPRMIB is set.
The SPRMIB is NOT set.
kDescFalse
Functional Description
This API can be always called while a diagnostic service processing is ongoing to get the
information about the SPRMIB state. All main-handlers do contain this information already
in the pMsgContext parameter so use it instead of this API.
In some other cases the application does not have access to the pMsgContext, and there
the API can be used.
Pre-conditions
Only for UDS configurations.
May be called only while a diagnostic service processing is ongoing. Otherwise invalid
data can be reported.
Call context
Any.
Particularities and Limitations > 12.6.6.4 ApplDescOnTransitionSession() ApplDescOnTransitionSession Available since 2.00.00 Is Reentrant Is callback Prototype
Single Context
void
ApplDescOnTransitionSession (DescStateGroup newState,
DescStateGroup formerState)
Multi Context
void
ApplDescOnTransitionSession (DescStateGroup newState,
DescStateGroup formerState)
2015, Vector Informatik GmbH
Version: 3.09.00
96 / 158
based on template version 5.1.0
Technical Reference CANdesc
Parameter newState
the CANdesc component has change to this session state
formerState
the CANdesc component has change from this session state
Return code -
-
Functional Description
After the positive response of a SessionControl request the session will transit to the
requested session. This function informs the application that such a transition occurs.
Pre-conditions -
Call context
From
DescTask()
interrupts might be disabled
Particularities and Limitations > Only informational function
12.6.6.5 DescSetStateSession() DescSetStateSession Available since 2.00.00 Is Reentrant Is callback Prototype
Single Context
void
DescSetStateSession (DescStateGroup newSession)
Multi Context
void
DescSetStateSession (DescStateGroup newSession)
Parameter newSession
the CANdesc component will change to this session state
Return code -
-
Functional Description
By this function the state of the SessionState-group can be changed by the ECU
application. The transition notification function ‘ApplDescOnTransitionSession’ will be
called to notify the application about the new session.
2015, Vector Informatik GmbH
Version: 3.09.00
97 / 158
based on template version 5.1.0
Technical Reference CANdesc
Pre-conditions -
Call context -
Particularities and Limitations > Please refer to sectio
n 12.6.11.2 "DescSetState<StateGroup>()” for more details.
12.6.6.6 DescGetStateSession() DescGetStateSession Available since 2.00.00 Is Reentrant Is callback Prototype
Single Context
currentSession
DescGetStateSession (void)
Multi Context
currentSession
DescGetStateSession (void)
Parameter -
Return code currentSession
Functional Description
This function returns the current session state. Since the states are bit-coded the
evaluation expressions may be optimized for multiple use cases.
Example: Code execution only when either default or extended session is active.
lState = DescGetStateSession();
if ( (lState & (kDescStateSession<Default>) | kDescStateSession<Extended>)) != 0 )
{
/*execute code*/
}
Pre-conditions -
Call context -
2015, Vector Informatik GmbH
Version: 3.09.00
98 / 158
based on template version 5.1.0
Technical Reference CANdesc
Particularities and Limitations > Please refer to sectio
n 12.6.11.1 “DescGetState<StateGroup>()” for more details.
12.6.6.7 DescGetSessionIdOfSessionState DescGetSessionIdOfSessionState Available since 3.00.00 Is Reentrant Is callback Prototype
Any Context
DescMsgItem
DescGetSessionIdOfSessionState (DescStateGroup sessionState)
Parameter sessionState
- Must be one of the valid session states (i.e. the value of the
API
DescGetStateSession() ).
Return code DescMsgItem
- Is the corresponding session identifier value.
Functional Description
This function provides a conversion from a session state to its corresponding session
identifier (e.g. calling this function with parameter
kDescStateSessionDefault will return
0x01).
Pre-conditions -
Call context -
Particularities and Limitations > 12.6.7 CommunicationControl Handling
This API is provided, if the ECU supports the serviceCommunicationControl (UDS) or
service 0x28/0x29 Dis-/EnableNormalMessageTransmission (KWP).
2015, Vector Informatik GmbH
Version: 3.09.00
99 / 158
based on template version 5.1.0
Technical Reference CANdesc
12.6.7.1 ApplDescCheckCommCtrl() ApplDescCheckCommCtrl Available since 2.00.00 Is callback Prototype
Single Context
void
ApplDescCheckCommCtrl (DescOemCommControlInfo* commControlInfo)
Multi Context
void
ApplDescCheckCommCtrl (vuint8 iContext,
DescOemCommControlInfo* commControlInfo)
Parameter iContext
The current request context location
commControlInfo
OEM dependent
Return code -
-
Functional Description
The execution of this service is completely done within the CANdesc component. This
hook function can be used to permit the application to reject the execution under some
circumstance. If the application wants to discard this request, an error must be set (via
DescSetNegResponse()).
The application always has to confirm this hook function (via
DescCommCtrlChecked()).
Pre-conditions
The CommunicationControl service must be activated and the attribute
‘MainHandlerSupport’ has to be set to ‘OEM’
Call context
From
DescTask() Particularities and Limitations > If the API function
DescCommCtrlChecked() will be not called, the service processing
will not end
12.6.7.2 DescCommCtrlChecked() DescCommCtrlChecked Available since 2.00.00 Is Reentrant Is callback Prototype
Single Context
2015, Vector Informatik GmbH
Version: 3.09.00
100 / 158
based on template version 5.1.0
Technical Reference CANdesc
void
DescCommCtrlChecked (void)
Multi Context
void
DescCommCtrlChecked (vuint8 iContext)
Parameter iContext
the current request context location
Return code -
-
Functional Description
The CANdesc component calls a hook function to check for the execution permission of
the CommunicationControl service. Within or after this hook function
(
ApplDescCheckCommCtrl()) the application can set an error
(
DescSetNegResponse()) to reject the request. This function is used to terminate the
hook function
ApplDescCheckCommCtrl(). Pre-conditions
The CommunicationControl service must be activated and the attribute
‘MainHandlerSupport’ has to be set to ‘OEM’
Call context
Within or after
ApplDescCheckCommCtrl() Particularities and Limitations > 12.6.8 Periodic call of ‘Service MainHandler’ 12.6.8.1 DescStartRepeatedServiceCall() DescStartRepeatedServiceCall Available since 2.00.00 Is Reentrant Is callback Prototype
Single Context
void
DescStartRepeatedServiceCall (DescMainHandler descMainHandler)
Multi Context
void
DescStartRepeatedServiceCall (vuint8 iContext, DescMainHandler descMainHandler)
Parameter descMainHandler
Reference to a function. The function prototype must be based
on a ‘Service MainHandler’.
2015, Vector Informatik GmbH
Version: 3.09.00
101 / 158
based on template version 5.1.0
Technical Reference CANdesc
iContext
The current request context location
Return code -
-
Functional Description
The application can use this function to get a periodic call to the specified function (in the
parameter) from the CANdesc component.
It is possible to use the same ‘Service MainHandler’ function as it is called in.
Pre-conditions Call context
Within or after a ‘Service MainHandler’ function
Particularities and Limitations > CANdesc can do no validation, if this pointer is valid.
> Is the parameter NULL, the periodic calls will get stopped.
> The function is called in the same cycle time (context) as the DescTask()
2015, Vector Informatik GmbH
Version: 3.09.00
102 / 158
based on template version 5.1.0
Technical Reference CANdesc
12.6.8.2 DescStartMemByAddrRepeatedCall() DescStartMemByAddrRepeatedCall Available since 5.06.04 Is Reentrant Is callback Prototype
Single Context
void
DescStartMemByAddrRepeatedCall ()
Multi Context
void
DescStartMemByAddrRepeatedCall (vuint8 iContext)
Parameter iContext
The current request context location
Return code -
-
Functional Description
The application can use this function to get a periodic call to the current Read/Write
memory by address handler.
Pre-conditions Call context
Within ApplDescReadMemoryByAddress or ApplDescWriteMemoryByAddress.
Particularities and Limitations > The memory access handler is called in the same cycle time (context) as the
DescTask()
12.6.9 Ring Buffer Mechanism
The ring-buffer option can be used to save RAM when some responses are quite long and
reserving such space of RAM is impossible. In contrast to the linear responses, where the
response data will be first written and then the transmission to the tester will be initiated,
the ring-buffer concept starts a transmission as soon as it has either the whole data (for
short [single frame] responses) or at least enough data to fill a first-frame of a multi-frame
transmission. Once the ring buffer has been activated and the response transmission
initiated, the application must supply enough data to keep the transmission away from lack
of data. In multiple PID mode, the application can decide in each PID main handler to use
the ring buffer or not. However, if one of the PIDs has dynamic length, the ring buffer
mechanism can not be used for any PID in the list.
2015, Vector Informatik GmbH
Version: 3.09.00
103 / 158
based on template version 5.1.0

Technical Reference CANdesc
Note
The ring buffer should only be used for long responses, because using the ring buffer
instead of the linear buffer causes a runtime overhead.
12.6.9.1 DescRingBufferStart() DescRingBufferStart
Available since 2.00.00 Is Reentrant Is callback Prototype
Single Context
void
DescRingBufferStart (void)
Multi Context
void
DescRingBufferStart (vuint8 iContext)
Parameter iContext
reference to the corresponding request context
Return code -
-
Functional Description
After completing the request validation the application can decide (in runtime), if the ring-
buffer mechanism should be used or not.
By calling this function, the decision is made to use the ring-buffer. Otherwise
DescProcessingDone() should be called, after filling the response data (in a linear way).
Either DescProcessingDone() or DescRingBufferStart() will finish the response handling.
Depending on the previous actions of the application the CANdesc module will either send
a response (positive/negative depending on the error state machine) or no response will
be send if the application/CANdesc decides that there must be no response (please refer
the Part III User Manual).
The transmission of the positive response will not start immediately. The application has to
fill the ring-buffer first. If the ring-buffer has enough data, the transmission will be started
(internally).
Pre-conditions - ring-buffer has been enabled in the configuration
Call context
Within or after a ‘Service MainHandler’ function
2015, Vector Informatik GmbH
Version: 3.09.00
104 / 158
based on template version 5.1.0
Technical Reference CANdesc
Particularities and Limitations > This API
must not be called from any of the other handler type (Pre- or PostHandlers)
> Either DescProcessingDone() or DescRingBufferStart() must be used to finish the
response handling.
> Total response length must be written before!
> No response data must be written before!
> This function
must not be called in interrupt context
> Limitation: Until CANdesc version 2.13.00 it was not possible to use the Ring-Buffer in
‘Multiple PID’ services (as described in section
9.3.3 Multiple PID mode) > UDS limitation: Always check the SPRMIB prior starting the ring-buffer. If this bit is
set, the ring-buffer shall not be started. Instead DescProcessingDone() must be called
(see
13.6). > When Repeated Service Call feature is used for polling a function that fills the Ring-
Buffer, then the function DescStartRepeatedServiceCall() must be called
after the
function DescRingBufferStart().
12.6.9.2 DescRingBufferWrite() DescRingBufferWrite Available since 2.00.00 Is Reentrant Is callback Prototype
Single Context
vuint8
DescRingBufferWrite (DescMsg data, DescMsgLen dataLength)
Multi Context
vuint8
DescRingBufferWrite (vuint8 iContext, DescMsg data, DescMsgLen dataLength)
Parameter iContext
Reference to the corresponding request context
DescMsg
Pointer to application data, which should be copied into ring-
buffer.
DescMsgLen
Amount of data, which should be copied (from pointer data) into
ring-buffer.
Return code vuint8
kDescOk If the copy process was successful
kDescFailed
if the data are
not copied into the ring-buffer
2015, Vector Informatik GmbH
Version: 3.09.00
105 / 158
based on template version 5.1.0
Technical Reference CANdesc
Functional Description
The application writes data into the ring-buffer by this function. It is not necessary that the
application must write the data in the context of a special API function.
The write order is always linear! The first written byte is the first byte in the response
message.
Pre-conditions
ring-buffer has been enabled in the configuration;
DescRingBufferStart() must be called first, to activate the ring-buffer mechanism.
Call context - This API shall not interrupt the DescTask. Required for the case the currently ongoing
transmission is interrupted due to a communication error, and the application still writes
into the buffer.
Particularities and Limitations > dataLength must be lower or equal to the ring-buffer size, else the function will
always fail
> CANdesc has already filled the first bytes (SID, etc.) into the ring-buffer. So in the first
call of DescRingBufferWrite() the dataLength must lower as the buffer size + these byte
12.6.9.3 DescRingBufferCancel() DescRingBufferCancel Available since 5.01.00 Is Reentrant Is callback Prototype
Single Context
void
DescRingBufferCancel (void)
Multi Context
void
DescRingBufferCancel (vuint8 iContext)
Parameter iContext
Reference to the corresponding request context
Return code -
-
2015, Vector Informatik GmbH
Version: 3.09.00
106 / 158
based on template version 5.1.0
Technical Reference CANdesc
Functional Description
The application may call this API once the a data acquisition error has been occurred after
the ring-buffer has been activated vi
a DescRingBufferStart(). CANdesc will automatically determine the appropriate action depending on its current
internal state:
if the response data transmission has not been started yet, a negative response will be
sent back.
If the response transmission has been started – a transmission interrupt will occur – the
tester will not get a complete response.
Pre-conditions
ring-buffer has been enabled in the configuration
DescRingBufferStart() must be called before to activate the ring-buffer mechanism
Call context -
Particularities and Limitations > 12.6.9.4 DescRingBufferGetFreeSpace() DescRingBufferGetFreeSpace Available since 2.00.00 Is Reentrant Is callback Prototype
Single Context
DescMsgLen
DescRingBufferGetFreeSpace (void)
Multi Context
DescMsgLen
DescRingBufferGetFreeSpace (vuint8 iContext)
Parameter iContext
reference to the corresponding request context
Return code DescMsgLen
The amount of free space/bytes in the ring-buffer.
Functional Description
This function returns the amount of free space/bytes in the ring-buffer.
Pre-conditions
ring-buffer has been enabled in the configuration
DescRingBufferStart() must be called before to activate the ring-buffer mechanism
2015, Vector Informatik GmbH
Version: 3.09.00
107 / 158
based on template version 5.1.0
Technical Reference CANdesc
Call context -
12.6.9.5 DescRingBufferGetProgress() DescRingBufferGetProgress Available since 2.00.00 Is Reentrant Is callback Prototype
Single Context
DescMsgLen
DescRingBufferGetProgress (void)
Multi Context
DescMsgLen
DescRingBufferGetProgress (vuint8 iContext)
Parameter iContext
reference to the corresponding request context
Return code DescRingBufferProgress Current byte position in the whole response.
Functional Description
This function returns the progress of the copy process.
Pre-conditions
ring-buffer has been enabled in the configuration
DescRingBufferStart() must be called before to activate the ring-buffer mechanism
Call context -
Particularities and Limitations > 12.6.10 Signal Interface of CANdesc
CANdesc will provide a signal interface to the ECU application. This can help the ECU
application to assemble the response automatically. No further code changes are
necessary, if a signal will move or change its size.
The current implementation has only support for a synchronous signal interface. This
means the ECU application has to provide the signal value within the call/context of the
Signal Handler function (while reading) or to write thewithin the call/context of the Signal
Handler function (while writing).
2015, Vector Informatik GmbH
Version: 3.09.00
108 / 158
based on template version 5.1.0
Technical Reference CANdesc
12.6.10.1 ApplDesc<Signal-Handler>() ApplDesc<Signal-Handler> Available since 2.00.00 Is callback Prototype
Single Context
-
ApplDesc<Service-Qualifier + Data-Object-Qualifier + Instance-Qualifier> (-)
Multi Context
-
ApplDesc<Service-Qualifier + Data-Object-Qualifier + Instance-Qualifier> (-)
Parameter vuint8, vsint8,
Available for write services.
vuint16, vsint16,
Type depend on signal type
vuint32, vsint32,
DescMsg (vuint8*)
DescMsg (vuint8*)
Available for read services and signals > 32 bit (N bit)
Return code vuint8, vsint8,
Available for read services.
vuint16, vsint16,
Type depend on signal type.
vuint32, vsint32
Functional Description
A Signal Handler is generated if the Service MainHandler is configured to be generated. In
this case, writing Signal Handlers are generated for all dataObjects transported with the
request and reading Signal Handlers are generated for all dataObjects transported with
the response (read/write from application point of view).
The data type of the Signal Handler argument depends on the dataObject which is to be
processed.
Pre-conditions
Must be configured to ‘generated’ in attribute ‘MainHandlerSupport’
Call context
From
DescTask() Particularities and Limitations > You can override the given name extension (Service-Qualifier + Data-Object-Qualifier
+ Instance-Qualifier) by using the SignalHandlerOverrideName.
12.6.10.2 Configuration of direct signal access
Application
variable
for
direct
access
(default
=
not
set)
If this variable is specified, an access to the given external (= application) variable is
generated. Nothing has to be done by the application. The external variable must be
defined inside the application.
2015, Vector Informatik GmbH
Version: 3.09.00
109 / 158
based on template version 5.1.0
Technical Reference CANdesc
SignalHandlerOverrideName
(default
=
not
set).
You can adapt the name of the Signal Handler setting this value. By using this “Override
Name” it is also possible to reuse an already existing Signal Handler
12.6.11 State Handling (CANdesc only) 12.6.11.1 DescGetState<StateGroup>() DescGetState<StateGroup> Available since 2.00.00 Is Reentrant Is callback Prototype
Single Context
DescStateGroup
DescGetState<StateGroup-Qualifier> (void)
Multi Context
DescStateGroup
DescGetState<StateGroup-Qualifier> (void)
Parameter -
-
Return code DescStateGroup
The current state of the state group
Functional Description
This function returns the current session state. Since the states are bit-coded the
evaluation expressions may be optimized for multiple use cases.
Example: Code execution only when either the current state of this group is either state X
or state Y.
lState = DescGetState<
StateGroupQualifier >();
if ( (lState & (kDescState<
StateGroupQualifier ><StateQualifier_X>) |
kDescState<
StateGroupQualifier ><StateQualifier_Y>)) != 0 )
{
/*execute code*/
}
Pre-conditions -
Call context -
Particularities and Limitations > For each state of a state-group a constant is defined in desc.h:
kDescState<StateGroup-Qualifier><StateQualifier> 2015, Vector Informatik GmbH
Version: 3.09.00
110 / 158
based on template version 5.1.0
Technical Reference CANdesc
12.6.11.2 DescSetState<StateGroup>() DescSetState<StateGroup> Available since 2.00.00 Is Reentrant Is callback Prototype
Single Context
void
DescSetState<StateGroup-Qualifier> (DescStateGroup newState)
Multi Context
void
DescSetState<StateGroup-Qualifier> (DescStateGroup newState)
Parameter DescStateGroup
the state in which the state group should be changed
Return code -
-
Functional Description
By this function the state of the state-group can be changed by the ECU application. The transition
notification function ‘ApplDescOnTransition< StateGroupQualifier >’ will be called to notify the
application about the new state.
Example:
DescSetState<StateGroupQualifier>(kDescState<StateGroupQualifier><StateQualifier>);
This line will force CANdesc to change the state of the given state group to the new one.
Pre-conditions -
Call context -From a task with priority lower or equal to the DescTask.
Particularities and Limitations > For each state of a state-group a constant will be defined in desc.h:
kDescState<StateGroup-Qualifier><State-Qualifier> > The
ApplDescOnTransition<StateGroup-Qualifier>() notification function is called in any
case. Also if the newState is the same as the current stat
2015, Vector Informatik GmbH
Version: 3.09.00
111 / 158
based on template version 5.1.0
Technical Reference CANdesc
12.6.11.3 ApplDescOnTransition«StateGroup»() ApplDescOnTransition«StateGroup» Available since 2.00.00 Is Reentrant Is callback Prototype
Single Context
void
ApplDescOnTransition<StateGroup-Qualifier>(DescStateGroup newState,
DescStateGroup formerState)
Multi Context
void
ApplDescOnTransition<StateGroup-Qualifier> (DescStateGroup newState,
DescStateGroup formerState)
Parameter newState
the CANdesc component has changed to this session state
formerState
the CANdesc component has changed from this session state
Return code -
-
Functional Description
This notification function will be called each time a transition has happened.
Pre-conditions -
Call context
From
DescTask()
interrupts might be disabled
Particularities and Limitations > For each state of a state-group a constant will be defined in desc.h:
kDescState<StateGroup-Qualifier><StateName-Qualifier> > For some exceptions (e.g. Session) the newState can be the same as the formerState.
2015, Vector Informatik GmbH
Version: 3.09.00
112 / 158
based on template version 5.1.0
Technical Reference CANdesc
12.6.12 Force “Response Correctly Received - Response Pending” transmission
In some cases it is useful for the application to be sure that it has enough time to
accomplish a process without causing the tester to get response timeout. In such cases
the application can use the “force RCR-RP” mechanism of CANdesc, which prevents
timeout between the tester and the ECU application.
How it works:
This feature is mostly applicable when a FlashBootLoader (FBL) is available for the ECU.
Before starting it, the application wants to assure that there is enough time to perform
reset and activate the FBL before the tester gets response timeout. The RCR-RP
mechanism notifies the tester that some action is ongoing and so resets the timeout timer
in the tester.
To transmit a ‘Response Correctly Received - Response Pending’ response the application
has to call the
DescForceRcrRpResponse() function. To be sure this response is
transmitted, the application has to wait for the transmission confirmation of this forced
RCR-RP response (the function
ApplDescRcrRpConfirmation). Depending on its
transmission status parameter the application can decide how the processing shall
continue (a jump to FBL or to close the request processingth negative response).
12.6.12.1 DescForceRcrRpResponse() DescForceRcrRpResponse Available since 2.11.00 Is Reentrant Is callback Prototype
Single Context
void
DescForceRcrRpResponse(void)
Multi Context
void
DescForceRcrRpResponse(vuint8 iContext)
Parameter iContext
reference to the corresponding request context
Return code -
-
Functional Description
Calling this function the application can force CANdesc to send immediately (not later than
the next call of DescTask() function) a RCR-RP response.
Pre-conditions
CANdesc was configured to use this option (enabled in the GENtool).
2015, Vector Informatik GmbH
Version: 3.09.00
113 / 158
based on template version 5.1.0
Technical Reference CANdesc
Call context
Task or interrupt.
Particularities and Limitations > This function can be called:
after a call of a MainHandler function (e.g.
ApplDescCheckSessionTransition())
and until the call of
ApplDescResponsePendingOverrun() or
ApplDescResponsePendingOvertimed() or
pConfirmation(). 12.6.12.2 ApplDescRcrRpConfirmation() ApplDescRcrRpConfirmation Available since 2.11.00 Is callback Prototype
Single Context
void
ApplDescRcrRpConfirmation(vuint8 status)
Multi Context
void
ApplDescRcrRpConfirmation(vuint8 iContext, vuint8 status)
Parameter iContext
Reference to the corresponding request context
status
If the transmission was successful, the parameter value will be
kDescOk. Otherwise –
kDescFailed. Return code -
-
Functional Description
Once the RCR-RP response has been forced, this function will be called in any case. The
transmission status is reported by the status parameter.
Pre-conditions
CANdesc was configured to use this option (enabled in the GENtool).
Call context
CAN Driver TX-ISR TP Confirmation this function
Particularities and Limitations > Be aware of time consuming implementation for this function (interrupt call context).
12.6.13 DynamicallyDefineDataIdentifier ($2C) (UDS) functions
Since this feature is only for some OEM available, please refer to the OEM specific documentation
to find out if is applicable for your configuration.
2015, Vector Informatik GmbH
Version: 3.09.00
114 / 158
based on template version 5.1.0
Technical Reference CANdesc
12.6.13.1 DescMayCallStateTaskAgain() DescMayCallStateTaskAgain Available since 4.00.00 Is Reentrant Is callback Prototype
Single Context
DescBool
DescMayCallStateTaskAgain (void)
Multi Context
DescBool
DescMayCallStateTaskAgain (void)
Parameter -
-
Return code kDescTrue
TRUE if you may call again the state task within this application
task cycle.
kDescFalse
FALSE if the DescStateTask() must not be called again.
Functional Description
Motivation: The
DescStateTask() can be called as fast as possible but it still can not be
enough fast for complex service processing (e.g. DDIDs containing long descriptions) to
match fast timing-performance requirements. This function provides the info if the
application may call again the state-task in the same task context without causing endless
loop (important for non-preemptive OS environments).
Example of the API usage:
void ApplDiagTask(void) /* application function called as fast as possible */
{
do /* pump the state task as long as needed */
{
DescStateTask();
}
while(
DescMayCallStateTaskAgain() == kDescTrue);
}
2015, Vector Informatik GmbH
Version: 3.09.00
115 / 158
based on template version 5.1.0
Technical Reference CANdesc
Pre-conditions - Preprocessor define “
DESC_ENABLE_HIPERFORMANCE_DYNDID_MODE” is
available (using user-config file in GENtool).
- The application uses the split-task concept (i.e. calls
DescState-/TimerTask() instead of
DescTask()).
Call context
Background-loop level or OSEK-OS Task. The Task should have a lower or equal priority
than all other interaction to the CANdesc component.
Particularities and Limitations > 12.6.13.2 ApplDescCheckDynDidMemoryArea() ApplDescCheckDynDidMemoryArea Available since 3.02.00 Must be Reentrant Is callback Prototype
Any Context
DescDynDidMemCheckResult
ApplDescCheckDynDidMemoryArea (
DescDynDidMemBlockAddress srcAddr,
DescDynDidMemBlockSize len );
Parameter srcAddr
Start address (Service $2C 02 request parameter ‘memoryAddress’).
len
Length of block to read (Service $2C 02 request parameter
‘memorySize’).
Return code
memBlockOk
Permit the access to requested memory block and extend the DDID.
memBlockInvAddress
Forbid the access due invalid requested memory address
(requestOutOfRange).
memBlockInvSize
Forbid the access due invalid requested block length
(requestOutOfRange).
memBlockInvSecurity
Forbid the access due current security mode settings prohibit the DDID
definition (securityAccessDenied).
memBlockInvCondition Forbid the access due other restrictions (conditionsNotCorrect).
If the memory access if forbidden, the Service $2C Request is negative responded with NRC 22
(conditionsNotCorrect), 31 (requestOutOfRange) or 33 (securityAccessDenied).
2015, Vector Informatik GmbH
Version: 3.09.00
116 / 158
based on template version 5.1.0

Technical Reference CANdesc
Functional Description
This callback function is triggered when defining a DDID that shall read bytes from the ECU’s
memory (Service Request $2C 02). The application can permit the (re-)definition of the DDID or
forbid it.
The service request is responded according to this.
The application must check
if the given srcAddr and following len bytes are valid ECU addresses and if they are readable,
if the current security state allows to define the DDID right now,
if there are other conditions that may forbid the definition of the DDID.
If all checks allow the DDID definition, the callback function must return memBlockOk.
FYI: When later reading the defined DDIDs by service $22, the standard checks [of Service $23
ReadMemoryByAddress] are executed, that perform security checks before accessing the
memory.
So, above security check with service $2C shall prove that the current security state permits the
definition of the DDID, the security check in service $22 (resp. $23) proves [in the context of the
then existing security state] the actual
reading of the memory range.
Pre-conditions -
Call context
From
DescTask() Particularities and Limitations 12.6.13.3 Non-volatile memory support
For some car-manufactures CANdesc provides NVRAM support for the dynamically
defined DID definitions. There are some APIs that must be operated and some call-backs
to be implemented by the application in order to get the NVRAM support fully operational.
The following diagrams show the two oeprations on NVRAM – restore (at power on) and st
ore (usuall prior power off) data.
Restore data at ECU power on Caution
At each CANdesc initialization (e.g. ECU reset/ power on) the “restore” procedure must
be performed!
2015, Vector Informatik GmbH
Version: 3.09.00
117 / 158
based on template version 5.1.0

Technical Reference CANdesc
Figure 12-1 DynDID definition restore and tester interaction
2015, Vector Informatik GmbH
Version: 3.09.00
118 / 158
based on template version 5.1.0


Technical Reference CANdesc
Store data at ECU power down Info The store operation can be performed at any time not only at power down.
Figure 12-2 Store DynDID definitions
12.6.13.3.1 DescDynDefineDidPowerUp() DescDynDefineDidPowerUp Available since 5.06.09 Is Reentrant Is callback Prototype
Single Context
void
DescDynDefineDidPowerUp (void)
Multi Context
void
DescDynDefineDidPowerUp (void)
2015, Vector Informatik GmbH
Version: 3.09.00
119 / 158
based on template version 5.1.0
Technical Reference CANdesc
Parameter -
-
Return code -
-
Functional Description
Once the ECU has been powered one/reset or just need to be reinitialized, this API must
be called to restore the dynamically defined DID content.
Usually called after the NVRAM manager is initialized.
Pre-conditions - Service 0x2C needs to store the DynDID definitions to the NVRAM (OEM specific
requirement)
Call context - any
Particularities and Limitations > Must be called after DescInitPowerOn().
12.6.13.3.2 DescDynIdMemContentRestored () DescDynIdMemContentRestored Available since 5.06.09 Is Reentrant Is callback Prototype
Single Context
void
DescDynIdMemContentRestored (DescDynDidStorageInfo storageInfo)
Multi Context
void
DescDynIdMemContentRestored (DescDynDidStorageInfo storageInfo)
Parameter storageInfo.nvData
Not used
The size (in bytes) of the restored table.
storageInfo.nvDataSize The stored checksum, calculated by CANdesc at store time.
storageInfo.checkSum
Return code -
-
2015, Vector Informatik GmbH
Version: 3.09.00
120 / 158
based on template version 5.1.0
Technical Reference CANdesc
Functional Description
After CANdesc has requested the application to restore the DynDID data
(“ApplDescRestoreDynIdMemContent ()”), this API must be called to notify CANdesc that
the DynDID content has been restored and can be used.
Pre-conditions - Service 0x2C needs to store the DynDID definitions to the NVRAM (OEM specific
requirement)
Call context - any
Particularities and Limitations > none
12.6.13.3.3 DescDynDefineDidPowerDown () DescDynDefineDidPowerDown Available since 5.06.09 Is Reentrant Is callback Prototype
Single Context
void
DescDynDefineDidPowerDown (void)
Multi Context
void
DescDynDefineDidPowerDown (void)
Parameter -
-
Return code -
-
Functional Description
If the ECU has to be reset or just power off /shutdown, this API must be called to store the
current DID definitions.
In order to save E2PROM write cycles, the application may perform compare to the
current E2PROM content and decide whether to store the table content or not.
Pre-conditions - Service 0x2C needs to store the DynDID definitions to the NVRAM (OEM specific
requirement)
Call context - any
2015, Vector Informatik GmbH
Version: 3.09.00
121 / 158
based on template version 5.1.0
Technical Reference CANdesc
Particularities and Limitations > Shall be called prior power-down/shutdown execution
> May be called any time to store the current content of the DynDID tables.
12.6.13.3.4 ApplDescStoreDynIdMemContent () ApplDescStoreDynIdMemContent Available since 5.06.09 Is Reentrant Is callback Prototype
Single Context
void
ApplDescStoreDynIdMemContent (DescDynDidStorageInfo storageInfo)
Multi Context
void
ApplDescStoreDynIdMemContent (DescDynDidStorageInfo storageInfo)
Parameter storageInfo.nvData
The pointer to the data to be stored;
The size (in bytes) of the table;
storageInfo.nvDataSize The checksum value, calculated by CANdesc, to be stored.
storageInfo.checkSum
Return code -
-
Functional Description
Once this API is called by CANdesc, the application must trigger a write E2PROM
procedure to store the data given by CANdesc and the checksum value.
In order to save E2PROM write cycles, the application may perform compare to the
current E2PROM content and decide whether to store the table content or not.
Pre-conditions - Service 0x2C needs to store the DynDID definitions to the NVRAM (OEM specific
requirement)
Call context - any
Particularities and Limitations > CANdesc does not keep the data pointed by the parameter pointer during the write
operation! The application must mirror the data if needed!
2015, Vector Informatik GmbH
Version: 3.09.00
122 / 158
based on template version 5.1.0
Technical Reference CANdesc
12.6.13.3.5 ApplDescRestoreDynIdMemContent () ApplDescRestoreDynIdMemContent Available since 5.06.09 Is Reentrant Is callback Prototype
Single Context
void
ApplDescRestoreDynIdMemContent (DescDynDidStorageInfo storageInfo)
Multi Context
void
ApplDescRestoreDynIdMemContent (DescDynDidStorageInfo storageInfo)
Parameter storageInfo.nvData
The pointer to the data to where the stored data shall be written
The size (in bytes) of the table expected.
storageInfo.nvDataSize Not used
storageInfo.checkSum
Return code -
-
Functional Description
Once this API is called by CANdesc, the application must trigger a read E2PROM
procedure to restore the data for CANdesc and the checksum value.
Once the read process has completed, the API
“DescDynIdMemContentRestored ()” must
be called to acknowledge the operation status to CANdesc.
Pre-conditions - Service 0x2C needs to store the DynDID definitions to the NVRAM (OEM specific
requirement)
Call context - any
Particularities and Limitations > 12.6.14 Memory Access Callbacks 12.6.14.1 ApplDescReadMemoryByAddress() ApplDescReadMemoryByAddress Available since 5.06.04 Is Reentrant Is callback 2015, Vector Informatik GmbH
Version: 3.09.00
123 / 158
based on template version 5.1.0
Technical Reference CANdesc
Prototype
Any Context
void
ApplDescReadMemoryByAddress (DescMsgContext* pMsgContext,
t_descMemByAddrInfo* pMemInfo)
Parameter pMsgContext
Please refer to sectio
n 12.6.4.2 Service MainHandler for
details about this parameter.
pMsgContext->resData
The response buffer pointer
pMsgContext->resDataLen The actual response length
pMemInfo->address
The address to read from
pMemInfo->length
The number of bytes to read
Return code -
-
Functional Description
This callback is called for read memory by address requests. The application has to do
following:
Perform memory block validation (negative response can be set by calling
DescSetNegResponse()). Optional: Perform additional state validations (negative response can be set by calling
DescSetNegResponse()). Copy the requested memory contents into the response buffer.
Set the response data length to the number of bytes copied.
Confirm that the processing is finished (by calling
DescProcessingDone()). Pre-conditions > The read memory by address service is supported.
> Please refer to chapter
9.5 Read/Write Memory by Address (SID $23/$3D) (UDS) for
more details of the availability of this API. If you don’t see this API provided in desc.h,
then this feature is not supported for your project.
Call context
From
DescTask() Particularities and Limitations > To call this handler periodically, ‘DescStartMemByAddrRepeatedCall’ needs to be used
2015, Vector Informatik GmbH
Version: 3.09.00
124 / 158
based on template version 5.1.0
Technical Reference CANdesc
12.6.14.2 ApplDescWriteMemoryByAddress() ApplDescWriteMemoryByAddress Available since 5.06.04 Is Reentrant Is callback Prototype
Any Context
void
ApplDescWriteMemoryByAddress (DescMsgContext* pMsgContext,
t_descMemByAddrInfo* pMemInfo)
Parameter pMsgContext
Please refer to sectio
n 12.6.4.2 Service MainHandler for
details about this parameter.
pMsgContext->reqData
The pointer to the data to store
pMemInfo->address
The address to write to
pMemInfo->length
The number of bytes to write
Return code -
-
Functional Description
This callback is called for write memory by address requests. The application has to do
following:
Perform memory block validation (negative response can be set by calling
DescSetNegResponse()). Optional: Perform additional state validations (negative response can be set by calling
DescSetNegResponse()). Copy the provided data into the memory area.
Confirm that the processing is finished (by calling
DescProcessingDone()). Pre-conditions > The write memory by address service is supported.
> Please refer to chapter
9.5 Read/Write Memory by Address (SID $23/$3D) (UDS) for
more details of the availability of this API. If you don’t see this API provided in desc.h,
then this feature is not supported for your project.
Call context
From
DescTask() Particularities and Limitations > To call this handler periodically, ‘DescStartMemByAddrRepeatedCall’ needs to be used
12.6.15 Flash Boot Loader Support
CANdesc provides some features to comply with the HIS flash boot loader procedures.
2015, Vector Informatik GmbH
Version: 3.09.00
125 / 158
based on template version 5.1.0
Technical Reference CANdesc
These features are not released for all OEMs so if the below listed APIs are not available
in your CANdesc version, then for the OEM, you currently use CANdesc, does not require,
resp. has another FBL procedures.
12.6.15.1 DescSendPosRespFBL() DescSendPosRespFBL Available since 4.05.00 Is Reentrant Is callback Prototype
Any Context
void
DescSendPosRespFBL (t_descFblPosRespType posRespSId)
Parameter posRespSId
One of the following values are allowed:
> kDescSendFblPosRespEcuHardReset
> kDescSendFblPosRespDscDefault.
Return code -
-
Functional Description
The application shall call this function as soon as possible after the initialization of the
CANdesc component is done and the ECU is able to communicate.
Once this function called, CANdesc will try to send the corresponding positive response
as follows:
> kDescSendFblPosRespEcuHardReset – a positive response to EcuHardReset ($51
$01) will be sent.
> kDescSendFblPosRespDscDefault – a positive response to DiagnosticSessionControl
Default session ($50 $01 $P2time $P2Star/10) will be sent.
If CANdesc is currently busy with a new tester request, there will be no response sent by
this API.
Pre-conditions
The FBL positive response feature is supported.
Call context
Any.
Particularities and Limitations > See
13.8 2015, Vector Informatik GmbH
Version: 3.09.00
126 / 158
based on template version 5.1.0
Technical Reference CANdesc
12.6.15.2 ApplDescInitPosResFblBusInfo() ApplDescInitPosResFblBusInfo Available since 5.07.04 Is Reentrant Is callback Prototype
Any Context
vuint8
ApplDescInitPosResFblBusInfo (t_descUsdtNetBus* pBusInfo)
Parameter pBusInfo
Reference to the bus information structure that will be
initialized here.
pBusInfo->busType
The bus driver that will send the response
pBusInfo->comChannel
The communication channel on which the response will be
sent. (relevant only on multi channel systems)
pBusInfo->testerId
The tester address which will be respond to. (relevant only on
bus systems with source/target addresses)
Return code kDescOk
Operation was successful, the FBL positive response will be
sent.
kDescFailed
Operation failed – no FBL positive response will be sent.
Functional Description
This callback is called once the application decided to call the API
DescSendPosRespFBL
to get the concrete addressing information.
The application shall initialize only the parameter described above. The optional ones can
be skipped if not relevant on your system.
Pre-conditions
The FBL positive response feature is supported.
Call context
From
DescSendPosRespFBL context.
Particularities and Limitations > -
12.6.16 Debug Interface / Assertion 12.6.16.1 ApplDescFatalError() ApplDescFatalError Available since 2.00.00 Is Reentrant Is callback 2015, Vector Informatik GmbH
Version: 3.09.00
127 / 158
based on template version 5.1.0
Technical Reference CANdesc
Prototype
Single Context
void
ApplDescFatalError (vuint8 errorCode, vuint16 lineNumber)
Multi Context
void
ApplDescFatalError (vuint8 errorCode, vuint16 lineNumber)
Parameter errorCode
The errorCode is a classification of the assertion. The
errorCodes can be also found in file ‘desc.h’. The errorCodes
are listed below:
lineNumber
A line number of file ‘desc.c’ from which this function is called.
Return code -
-
Functional Description
The CANdesc debug interface is similar to assertion constructof common programming
languages. Assertions are code checks which are written so that they should always
evaluate to true. If an assertion is false, it indicates a possible bug in the program, corrupt
system state or a misoperation of the user-interface.
CANdesc is calling the function ApplDescFatalError() function to indicate a evaluation of
an assertion to false. If this will happen it is recommended to halt the program's execution
immediately. This could be reach by an endless loop in that call-back.
The assertions can be disabled in the GenTool settings. The resource (ROM and runtime)
consumption can be reduced by disabling the assertions.
Error codes
kDescAssertWrongTpTxChannel (0x00):
The wrong TP channel is used – verify the TP interface to the CANdesc component
kDescAssertIndexTableInvalidReference (0x02):
Internal generation failure.
kDescAssertSvcTableUnreachableItem (0x03):
Internal generation failure.
kDescAssertSvcTableInvalidReference (0x04):
Internal generation failure.
kDescAssertSvcTableInconsistentNumber (0x05):
Internal generation failure.
2015, Vector Informatik GmbH
Version: 3.09.00
128 / 158
based on template version 5.1.0
Technical Reference CANdesc
kDescAssertMissingMainHandler (0x06):
Internal generation failure.
kDescAssertInvalidContextId (0x08):
Wrong iContext should be used - Check the consistency of the iContext parameter in the
application.
kDescAssertSvcTableIndexOutOfRange (0x09):
Internal generation failure.
kDescAssertSvcInstTableIndexOutOfRange (0x0A):
Internal generation failure.
kDescAssertContextIdWasModified (0x0B):
The iContext member of the pMsgContext parameter in the MainHandler functions are
illegal modified – verify the MainHandler functions in the application
kDescAssertProcessingDoneCallAfterResFlushing (0x0E):
DescProcessingDone() is called at least twice for one request – check the call of
DescProcessingDone() in the application.
kDescAssertTooLongSingleFrameResponse (0x0F):
Response lengthof a periodic DID is exceeding the SingleFrame length – check the
response length for periodic DIDs.
kDescAssertApplLackOfConfirmation (0x11):
The time for response processing is too long – verify if the call of DescProcessingDone()
is done in any case.
kDescAssertZeroStateValue (0x13):
The state parameter is zero – check state handling
kDescAssertInvalidContextMode (0x16):
Internal runtime error
kDescAssertUnexpectedWriteIntoRingBuffer (0x17):
DescRingBufferWrite() is called without activated ring-buffer
kDescAssertRingBufferWriteExceedsTheResLen (0x18):
DescRingBufferWrite() is called to often
kDescAssertIllegalUsageOfNegativeResponse (0x1A):
After call of DescProcessingDone() a negative response is set
2015, Vector Informatik GmbH
Version: 3.09.00
129 / 158
based on template version 5.1.0
Technical Reference CANdesc
kDescAssertDiagnosticBufferOverflow (0x1B):
currently not available
kDescAssertFuncReqWoResMayNotUseRingBuffer (0x1C):
It is not possible to use the ring-buffer feature for functional request (KWP only)
kDescAssertSchedulerTimerEventWithoutAnyPID (0x1E):
Internal runtime error
kDescAssertSchedulerRingBufferIsActivated (0x1F):
For periodic DIDs it is not possible to use the ring-buffer.
kDescAssertUnknownTpTransmissionType (0x21):
Internal runtime error
kDescAssertIllegalAddRequestCount (0x22):
Internal runtime error
kDescAssertNoSidCanBeReportedInIdleMode (0x23):
Call of DescGetSeriveId() while not a user-service is processed
kDescAssertInvalidUsageOfForceRcrRpApi (0x24):
The DescForceRcrRpResponse() function is used illegal.
kDescAssertPidResLenToCddDefNotMatched (0x26):
The response length set by the application do not fit to the response length defined in
CANdela (cdd).
kDescAssertPidResLenToCurrLinearFreeSpace (0x27):
Internal runtime error
kDescAssertMissingDataForTransmission (0x28):
Internal runtime error
kDescAssertSchedulerFreeCellNotFound (0x29):
Internal runtime error
kDescAssertInvalidStateParameterValue (0x2A):
The state parameter value is wrong – check state handling in your application
kDescAssertNoFreeICNChannel (0x2B):
Internal runtime error
2015, Vector Informatik GmbH
Version: 3.09.00
130 / 158
based on template version 5.1.0
Technical Reference CANdesc
kDescAssertInvalidDescICNClient (0x2C):
Internal runtime error
kDescAssertNoFreeMsgContext (0x2D):
Internal runtime error
kDescAssertUnExpectedContextWithResponse (0x2E):
A response will be sent out of a wrong context.
kDescAssertIllegalCallOfRingBufferCancel (0x2F):
The API
DescRingBufferCancel() has been called for a response that is not using the ring-
buffer concept (e.
g. DescRingBufferStart() was not called).
kDescNetAssertWrongIsoTpRxChannel (0x40):
The wrong TP channel is used – verify the TP interface to the CANdesc component
kDescNetAssertWrongIsoTpTxChannel (0x41):
The wrong TP channel is used – verify the TP interface to the CANdesc component
kDescNetAssertWrongBusType (0x42):
The wrong bus type is used – verify the TP interface to the CANdesc component
kDescAssertDescIcnIllegalTargetPointer (0x50):
Internal runtime assertion
Pre-conditions
At least on type of assertions are activated
Call context
Form ISR or task level. The interrupts might be disabled
Particularities and Limitations > After a call of this function the system is not stable anymore. It can not be guaranteed
that this component or the whole system is still working in correct manner.
12.6.17 “Spontaneous Response” transmission To implement the service $86 (Respone On Event) it is necessary to transmit a message
without a previous request. If the same CAN ID have to be used for this reponse as for the
diagnostics response, CANdesc provides an API to trigger the transmission.
12.6.17.1 DescSendApplSpontaneousResponse () DescSendApplSpontaneousResponse Available since 6.09.00 Is Reentrant Is callback 2015, Vector Informatik GmbH
Version: 3.09.00
131 / 158
based on template version 5.1.0
Technical Reference CANdesc
Prototype
Any Context
DescBool
DescSendApplSpontaneousResponse (DescMsg resData,
DescMsgLen resLen,
t_descUsdtNetBus* pBusInfo)
Parameter resData
Pointer to an application buffer with response data (including
posive response header).
resLen
Number of bytes to be sent (up to 4095 bytes).
pBusInfo
Reference to the bus information structure that will be initialized
here.
pBusInfo->busType
The bus driver that will send the response.
pBusInfo->comChannel
The communication channel on which the response will be sent.
(relevant only on multi channel systems).
pBusInfo->testerId
The tester address which will be respond to (relevant only on
bus systems with source/target addresses).
Return code kDescTrue
Operation was successful, the response will be sent.
kDescFalse
Operation failed – no response will be sent.
Functional Description Calling this function the application can force CANdesc to send immediately a
spontaneous response.
If CANdesc is currently busy with a tester request, there will be no response sent by this
API and kDescFalse will be returned.
If this API returns kDescTrue, the application shall wait for the
ApplDescSpontaneousResponseConfirmation() prior initiating a new spontaneous
transmission.
Pre-conditions
The API is available under one of the following conditions:
CANdesc was configured to use this option (enabled in the GENtool). Only
possible to configure if Service 0x86 is contained in the cdd.
For specific OEMs in case FBL behavior according to HIS is required (please refer
to
13.8…send a positive response without request after FBL flash job) Call context
Task or interrupt.
Particularities and Limitations > -
2015, Vector Informatik GmbH
Version: 3.09.00
132 / 158
based on template version 5.1.0
Technical Reference CANdesc
12.6.17.2 ApplDescSpontaneousResponseConfirmation() ApplDescSpontaneousResponseConfirmation Available since 6.09.00 Is callback Prototype
Single Context
void
ApplDescSpontaneousResponseConfirmation(vuint8 status)
Multi Context
void
ApplDescSpontaneousResponseConfirmation (vuint8 iContext, vuint8 status)
Parameter iContext
Will be always “kDescPrimContext”.
status
If the transmission was successful, the parameter value will be
kDescOk. Otherwise –
kDescFailed. Return code -
-
Functional Description
Once the spontaneous response has been successfully triggered (ref.
DescSendApplSpontaneousResponse ()), this function will be called in any case. The
transmission status is reported by the status parameter.
Pre-conditions
Only available if the API
DescSendApplSpontaneousResponse () is available.
Call context
CAN Driver TX-ISR TP Confirmation this function
Particularities and Limitations > Be aware of time consuming implementation for this function (interrupt call context).
2015, Vector Informatik GmbH
Version: 3.09.00
133 / 158
based on template version 5.1.0
Technical Reference CANdesc
12.6.18 Generic Processing Notifications 12.6.18.1 ApplDescManufacturerIndication ApplDescManufacturerIndication Available since 6.13.00 Is callback Prototype
Single Context
void
ApplDescManufacturerIndication(vuint8 sid,
vuint8* data,
vuint16 length,
vuint8 reqType,
t_descUsdtNetBus* pBusInfo)
Multi Context
void
ApplDescManufacturerIndication(vuint8 iContext,
vuint8 sid,
vuint8* data,
vuint16 length,
vuint8 reqType,
t_descUsdtNetBus* pBusInfo)
Parameter iContext
The current request context location
(used only as a handle -
DO NOT MODIFY).
sid
The service identifier of the received service request.
data
Pointer to the first byte of the request data (without service
identifier byte).
length
Length of the request data (without service identifier byte)
reqType
The current request addressing method. Could be either
‚kDescFuncReq’ or ‚kDescPhysReq’
(bitmapped).
pBusInfo
The current request communication information (i.e. driver type
(CAN, MOST, FlexRay, etc.), addressing information,
communication channel number, tester address (if applicable)
etc.
Return code -
-
2015, Vector Informatik GmbH
Version: 3.09.00
134 / 158
based on template version 5.1.0
Technical Reference CANdesc
Functional Description
This function is called right before CANdesc starts the processing of a received request.
Pre-conditions
Only available if the feature “Manufacturer Notification Support” is activated and CANdesc
UDS2012 is used.
Call context
From
DescTask() Particularities and Limitations > 12.6.18.2 ApplDescManufacturerConfirmation ApplDescManufacturerConfirmation Available since 6.13.00 Is callback Prototype
Single Context
void
ApplDescManufacturerConfirmation(vuint8 status)
Multi Context
void
ApplDescManufacturerConfirmation(vuint8 iContext,
vuint8 status)
Parameter iContext
The current request context location
(used only as a handle -
DO NOT MODIFY).
status
kDescPostHandlerStateOk The positive response was transmitted successfully
kDescPostHandlerStateNegResSent It was a negative response
kDescPostHandlerStateTxFailed A transmission error occurred
Return code -
-
Functional Description
This function is called after the processing of a request has been finished, a response has
been sent (or sending has failed) and all service PostHandlers were called.
Pre-conditions
Only available if the feature “Manufacturer Notification Support” is activated and CANdesc
UDS2012 is used.
2015, Vector Informatik GmbH
Version: 3.09.00
135 / 158
based on template version 5.1.0
Technical Reference CANdesc
Call context
From
DescTask () Particularities and Limitations > 12.6.18.3 ApplDescSupplierIndication ApplDescSupplierIndication Available since 6.13.00 Is callback Prototype
Single Context
void
ApplDescSupplierIndication(vuint8 sid,
vuint8* data,
vuint16 length,
vuint8 reqType,
t_descUsdtNetBus* pBusInfo)
Multi Context
void
ApplDescSupplierIndication(vuint8 iContext,
vuint8 sid,
vuint8* data,
vuint16 length,
vuint8 reqType,
t_descUsdtNetBus* pBusInfo)
Parameter iContext
The current request context location
(used only as a handle -
DO NOT MODIFY).
sid
The service identifier of the received service request.
data
Pointer to the first byte of the request data (without service
identifier byte).
length
Length of the request data (without service identifier byte)
reqType
The current request addressing method. Could be either
‚kDescFuncReq’ or ‚kDescPhysReq’
(bitmapped).
2015, Vector Informatik GmbH
Version: 3.09.00
136 / 158
based on template version 5.1.0
Technical Reference CANdesc
pBusInfo
The current request communication information (i.e. driver type
(CAN, MOST, FlexRay, etc.), addressing information,
communication channel number, tester address (if applicable)
etc.
Return code -
-
Functional Description
This function is called during the processing of a request, after CANdesc has verified that
the requested service is allowed in the active session and security state.
Pre-conditions
Only available if the feature “Supplier Notification Support” is activated and CANdesc
UDS2012 is used.
Call context
From
DescTask() Particularities and Limitations > 12.6.18.4 ApplDescSupplierConfirmation ApplDescSupplierConfirmation Available since 6.13.00 Is callback Prototype
Single Context
void
ApplDescSupplierConfirmation(vuint8 status)
Multi Context
void
ApplDescSupplierConfirmation(vuint8 iContext,
vuint8 status)
Parameter iContext
The current request context location
(used only as a handle -
DO NOT MODIFY).
status
kDescPostHandlerStateOk The positive response was transmitted successfully
kDescPostHandlerStateNegResSent It was a negative response
kDescPostHandlerStateTxFailed A transmission error occurred
Return code -
-
2015, Vector Informatik GmbH
Version: 3.09.00
137 / 158
based on template version 5.1.0
Technical Reference CANdesc
Functional Description
This function is called after the processing of a request has been finished, a response has
been sent (or sending has failed) and all service PostHandlers were called. It is called
before
ApplDescManufacturerConfirmation().
Pre-conditions
Only available if the feature “Supplier Notification Support” is activated and CANdesc
UDS2012 is used.
Call context
From
DescTask () Particularities and Limitations > 2015, Vector Informatik GmbH
Version: 3.09.00
138 / 158
based on template version 5.1.0
Technical Reference CANdesc
13 How To… 13.1 …implement a protocol service MainHandler //1. Read ProtocolService
// - dynamic length
// - PIDs
void DESC_API_CALLBACK_TYPE
ApplDescManiOnTimerEvent_storeEvent(DescMsgContext
* pMsgContext)
{
/* Check the length */ if(pMsgContext
->reqDataLen
> 2)
{
/* Check the sub-parameters */ vuint16 param;
/* Compose one parameter combining the HiByte and the LoByte in this order*/ param
= DescMake16Bit(pMsgContext
->reqData[0], pMsgContext
->reqData[1]);
/* Dispatch the parameter */ switch(param)
{
case 0xFFFF
: if(pMsgContext
->reqDataLen
!= 0xFFFF)
{
/* Write some data (skip the parameter offsets 0 und 1) */ pMsgContext
->resData[2]
= DescGetLoByte(0x1234);
pMsgContext
->resData[3]
= DescGetHiByte(0x1234);
/* Set the response length */ pMsgContext
->resDataLen
= 4;
}
else {
DescSetNegResponse(pMsgContext
->iContext, kDescNrcInvalidFormat);
}
break;
default: /* unknown parameter */ DescSetNegResponse(pMsgContext
->iContext, kDescNrcInvalidFormat);
}
}
else {
DescSetNegResponse(pMsgContext
-iContext, kDescNrcInvalidFormat);
}
/* In this case we did everything in the main-handler */ DescProcessingDone(pMsgContext
->iContext);
}
//2. Read ProtocolService
// - dynamic length
// - sub-function 2015, Vector Informatik GmbH
Version: 3.09.00
139 / 158
based on template version 5.1.0
Technical Reference CANdesc
void DESC_API_CALLBACK_TYPE
ApplDescManiOnTimerEvent_storeEvent(DescMsgContext
* pMsgContext)
{
/* Check the length */ if(pMsgContext
->reqDataLen
> 1)
{
/* Dispatch the sub-function */ switch(pMsgContext
->reqData[0])
{
case 0xFF
: if(pMsgContext
->reqDataLen
!= 0xFFFF)
{
/* Format check ok: write some data (skip the parameter) */ pMsgContext
->resData[1]
= DescGetLoByte(0x1234);
pMsgContext
->resData[2]
= DescGetHiByte(0x1234);
/* Set the response length */ /* Hint: if the response length wasn't set, zero value is assumed! */ pMsgContext
->resDataLen
= 3;
}
else {
/* Wrong sub-parameter format */ DescSetNegResponse(pMsgContext
->iContext, kDescNrcInvalidFormat);
}
break;
default: /* Unknown sub-function */ DescSetNegResponse(pMsgContext
->iContext,
kDescNrcSubfunctionNotSupported);
}
}
else {
DescSetNegResponse(pMsgContext
-iContext, kDescNrcInvalidFormat);
}
/* In this case we did everything in the main-handler */ DescProcessingDone(pMsgContext
->iContext);
}
//3. Write ProtocolService
// - dynamic length
// - PIDs
void DESC_API_CALLBACK_TYPE
ApplDescManiOnTimerEvent_storeEvent(DescMsgContext
* pMsgContext)
{
/* Check the sub-parameters */ vuint16 param;
/* Check the length */ if(pMsgContext
->reqDataLen
> 2)
{
/* Compose one parameter combining the HiByte and the LoByte in this order
*/ param
= DescMake16Bit(pMsgContext
->reqData[0], pMsgContext
->reqData[1]);
/* Dispatch the parameter */ switch(param)
{
2015, Vector Informatik GmbH
Version: 3.09.00
140 / 158
based on template version 5.1.0
Technical Reference CANdesc
case 0xFFFF
: if(pMsgContext
->reqDataLen
!= 0xFFFF)
{
/* Copy from the request data to your application */ /* Use the data pointed by: pMsgContext->reqData[2],
pMsgContext->reqData[3], etc.*/ }
else {
DescSetNegResponse(pMsgContext
->iContext, kDescNrcInvalidFormat);
}
break;
default: /* unknown parameter */ DescSetNegResponse(pMsgContext
->iContext, kDescNrcRequestOutOfRange);
}
}
else {
DescSetNegResponse(pMsgContext
-iContext, kDescNrcInvalidFormat);
}
/* In this case we did everything in the main-handler */ /* Hint: if the response length wasn't set, zero value is assumed! */ DescProcessingDone(pMsgContext
->iContext);
}
//4. Write ProtocolService
// - dynamic length
// - Sub-function
void DESC_API_CALLBACK_TYPE
ApplDescManiOnTimerEvent_storeEvent(DescMsgContext
* pMsgContext)
{
/* Check the sub-parameters */ vuint16 param;
/* Check the length */ if(pMsgContext
->reqDataLen
> 2)
{
/* Compose one parameter combining the HiByte and the LoByte in this order*/ param
= DescMake16Bit(pMsgContext
->reqData[0], pMsgContext
->reqData[1]);
/* Dispatch the parameter */ switch(param)
{
case 0xFFFF
: if(pMsgContext
->reqDataLen
!= 0xFFFF)
{
/* Copy from the request data to your application */ /* Use the data pointed by: pMsgContext->reqData[2],
pMsgContext->reqData[3], etc.*/ }
else {
DescSetNegResponse(pMsgContext
->iContext, kDescNrcInvalidFormat);
}
break;
default: /* unknown sub-function /
DescSetNegResponse(pMsgContext->iContext,
2015, Vector Informatik GmbH
Version: 3.09.00
141 / 158
based on template version 5.1.0
Technical Reference CANdesc
kDescNrcSubfunctionNotSupported);
}
}
else {
DescSetNegResponse(pMsgContext
-iContext, kDescNrcInvalidFormat);
}
/* In this case we did everything in the main-handler */ /* Hint: if the response length wasn't set, zero value is assumed! */ DescProcessingDone(pMsgContext
->iContext);
}
13.2 …implement a service MainHandler //5. Read Service
// - dynamic length
// - sub-function/PID
void DESC_API_CALLBACK_TYPE
ApplDescManiOnTimerEvent_storeEvent(DescMsgContext
* pMsgContext)
{
/* Check the length */ if(pMsgContext
->reqDataLen
!= 0xFFFF)
{
/* Format check ok: write some data */ pMsgContext
->resData[0]
= DescGetLoByte(0x1234);
pMsgContext
->resData[1]
= DescGetHiByte(0x1234);
/* Set the response length */ /* Hint: if the response length wasn't set, zero value is assumed! */ pMsgContext
->resDataLen
= 2;
}
else {
/* Wrong sub-function format */ DescSetNegResponse(pMsgContext
->iContext, kDescNrcInvalidFormat);
}
/* In this case we did everything in the main-handler */ DescProcessingDone(pMsgContext
->iContext);
}
//6. Read Service
// - static length
// - sub-function/PID
void DESC_API_CALLBACK_TYPE
ApplDescManiOnTimerEvent_storeEvent(DescMsgContext
* pMsgContext)
{
/* Format check ok: write some data */ pMsgContext
->resData[0]
= DescGetLoByte(0x1234);
pMsgContext
->resData[1]
= DescGetHiByte(0x1234);
/* Set the response length */ /* Hint: if the response length wasn't set, zero value is assumed! */ pMsgContext
->resDataLen
= 2;
/* In this case we did everything in the main-handler */ 2015, Vector Informatik GmbH
Version: 3.09.00
142 / 158
based on template version 5.1.0
Technical Reference CANdesc
DescProcessingDone(pMsgContext
->iContext);
}
//7. Write Service
// - dynamic length
// - sub-function/PID
void DESC_API_CALLBACK_TYPE
ApplDescManiOnTimerEvent_storeEvent(DescMsgContext
* pMsgContext)
{
/* Check the length */ if(pMsgContext
->reqDataLen
!= 0xFFFF)
{
/* Format check ok: write some data */ /* Copy from the request data to your application */ /* Use the data pointed by: pMsgContext->reqData[0],
pMsgContext->reqData[1], etc.*/ }
else {
/* Wrong sub-function format */ DescSetNegResponse(pMsgContext
->iContext, kDescNrcInvalidFormat);
}
/* In this case we did everything in the main-handler */ /* Hint: if the response length wasn't set, zero value is assumed! */ DescProcessingDone(pMsgContext
->iContext);
}
//8. Write Service
// - static length
// - sub-function/PID
void DESC_API_CALLBACK_TYPE
ApplDescManiOnTimerEvent_storeEvent(DescMsgContext
* pMsgContext)
{
/* Copy from the request data to your application */ /* Use the data pointed by: pMsgContext->reqData[0], pMsgContext->reqData[1],
etc.*/ /* In this case we did everything in the main-handler */ /* Hint: if the response length wasn't set, zero value is assumed! */ DescProcessingDone(pMsgContext
->iContext);
}
13.3 …implement a Signal Handler //1. ReadSignalHandler
// - length <= 4Byte
// Limitations: No DescProcessingDone() or DescSetNegResponse() allowed.
vuintx DESC_API_CALLBACK_TYPE
ApplDescGetTemp(
void)
{
/* Return directly the signal value */ return (vuintx)0xFFFF;
2015, Vector Informatik GmbH
Version: 3.09.00
143 / 158
based on template version 5.1.0
Technical Reference CANdesc
}
//2. ReadSignalHandler
// - length > 4Byte
// Limitations: No DescProcessingDone() or DescSetNegResponse() allowed.
DescMsgLen DESC_API_CALLBACK_TYPE
ApplDescGetTemp(DescMsg tgt)
{
/* Copy the signal data into the buffer pointed by "tgt".*/ /* Return the amount of written bytes */ return 0;
}
//3. WriteSignalHandler
// - length <= 4Byte
// Limitations: No DescProcessingDone() or DescSetNegResponse() allowed.
void DESC_API_CALLBACK_TYPE
ApplDescGetTemp(vuintx data)
{
/* "data" contains the signal value as-is from the request.
Copy it into your application. */ }
//4. ReadSignalHandler
// - length > 4Byte
// Limitations: No DescProcessingDone() or DescSetNegResponse() allowed.
DescMsgLen DESC_API_CALLBACK_TYPE
ApplDescGetTemp(DescMsg src)
{
/* Copy the signal data from the buffer pointed by "src".*/ /* Return the amount of copied bytes */ return 0;
}
13.4 …implement a Packet Handler //1. ReadPacketHandler
// Limitations: No DescProcessingDone() or DescSetNegResponse() allowed.
void DESC_API_CALLBACK_TYPE
ApplDescGetTemp(DescMsg pMsg)
{
/* Copy the signal value into the "pMsg" buffer. */ pMsg[0]
= DescGetLoByte(0x1234);
pMsg[1]
= DescGetLoByte(0x1234);
}
13.5 …implement a state transition function //1. StateTransitionNotification
// Limitations: No DescProcessingDone() or DescSetNegResponse() allowed. 2015, Vector Informatik GmbH
Version: 3.09.00
144 / 158
based on template version 5.1.0
Technical Reference CANdesc
void DESC_API_CALLBACK_TYPE
ApplDescOnTransitionSession(DescStateGroup
formerState, DescStateGroup newState)
{
/* You are just notified that this state group has performed a transition from
* "formerState" to the "newState". */ }
2015, Vector Informatik GmbH
Version: 3.09.00
145 / 158
based on template version 5.1.0
Technical Reference CANdesc
13.6 …work with the ring-buffer mechanism 13.6.1 with asynchronous write TPMC
Desc
Appl_MainHandler
Appl_MainHandler_2
EEPROM
Appl_PostHandler
Driver
call
Analyze and validate request
It is not possible to write data as in
Write response length the standard way if a ring-buffer will
be used (standard way is, to write to
DescMsgContext->ResData)
DescRingBufferStart()
DescRingBufferWrite(* dataPtr, dataLength)
Now - it is possibel to
Enough data are
write data to the ring-buffer
stored in the
ring-buffer to start
the transmission
DescRingBufferWrite(* dataPtr, dataLength)
DescRingBufferWrite(* dataPtr, dataLength)
StartTransmission
Not enough free
bytes to write
new data
TP reads
asynchronous the
DescRingBufferGetFreeSpace
data out of the
ring-buffer
return countOfFreeBytesInRingBuffer
TpCopyToCan
DescRingBufferGetFreeSpace
return countOfFreeBytesInRingBuffer
DescRingBufferWrite(* dataPtr, dataLength)
TpCopyToCan
DescRingBufferGetProgress
return currentBytePosition
FinishTransmission
Call of Service Post Handler
//1. Read Service (with asynchronous Ring-Buffer)
// - static length
// - sub-function/PID
vuint8 g_iContext;
2015, Vector Informatik GmbH
Version: 3.09.00
146 / 158
based on template version 5.1.0
Technical Reference CANdesc
void DESC_API_CALLBACK_TYPE
ApplDescReadDTC(DescMsgContext
* pMsgContext)
{
vuint8 lData;
/* Format check already done by CANdesc */ /* Analysis of request has to done by ECU application */ /* Set the response length */ pMsgContext
->resDataLen
= 16;
/* Fill the first data */ lData
= 5;
/* Store iContext for further interaction with CANdesc */ g_iContext
= pMsgContext
->iContext;
/* check only on services with sub-function (e.g. 0x19) */ if(pMsgContext
->msgAddInfo.suppPosRes != 0)
{
/* since no response required – skip further processing */ DescProcessingDone(pMsgContext
->iContext);
}
else
{
/* Now we have to set CANdesc into the Ring-Buffer mode */ DescRingBufferStart(pMsgContext
->iContext);
/* Now it is possible to write into the Ring-Buffer */ DescRingBufferWrite(pMsgContext
->iContext, &lData, 1);
/* Now trigger e.g. an EEPROM read event */ ...
}
}
EEPROM_TASK(xyz)
{
vuint8 lDTC[3];
... /* Wait for EEPROM event */ /* EEPROM event is finished with reading */ {
DescRingBufferWrite(g_iContext, &lDTC, 3);
/* Now trigger next EEPROM reading */ }
}
2015, Vector Informatik GmbH
Version: 3.09.00
147 / 158
based on template version 5.1.0
Technical Reference CANdesc
13.6.2 with synchronous write Desc
Appl_MainHandler
Appl_MainHandler_2
EEPROM
Appl_PostHandler
Driver
call
Analyze and validate request
write response length
DescRingBufferStart
DescRingBufferWrite(* dataPtr, dataLength)
DescStartRepeatedServiceCall(&ApplMainHandler_2)
Within this function
Activate the
call the data can be
multiple service
written synchronous.
call to get a
periodic call from
CANdesc
call
GetEEPROMData
DescRingBufferWrite(* dataPtr, dataLength)
call
DescRingBufferGetFreeSpace
return countOfFreeBytesInRingBuffer
call
DescRingBufferGetFreeSpace
return countOfFreeBytesInRingBuffer
GetEEPROMData
DescRingBufferWrite(* dataPtr, dataLength)
PostHandler
//2. Read Service (with synchronous Ring-Buffer)
// - static length
// - sub-function/PID
extern void ApplDescReadDTC_AddOn(DescMsgContext
* pMsgContext);
void DESC_API_CALLBACK_TYPE
ApplDescReadDTC(DescMsgContext
* pMsgContext)
{
vuint8 lData;
/* Format check already done by CANdesc */ 2015, Vector Informatik GmbH
Version: 3.09.00
148 / 158
based on template version 5.1.0
Technical Reference CANdesc
/* Analysis of request has to done by ECU application */ /* Set the response length */ pMsgContext
->resDataLen
= 16;
/* Fill the first data */ lData
= 5;
/* check only on services with sub-function (e.g. 0x19) */ if(pMsgContext
->msgAddInfo.suppPosRes != 0)
{
/* since no response required – skip further processing */ DescProcessingDone(pMsgContext
->iContext);
}
else
{
/* Now we have to set CANdesc into the Ring-Buffer mode */ DescRingBufferStart(pMsgContext
->iContext);
/* Now it is possible to write into the Ring-Buffer */ DescRingBufferWrite(pMsgContext
->iContext, &lData, 1);
/* Use RepeatedSeriveCall feature to poll e.g. EEPROM driver */ DescStartRepeatedServiceCall(pMsgContext
->iContext, &ApplDescReadDTC_AddOn);
}
}
void ApplDescReadDTC_AddOn(DescMsgContext
* pMsgContext)
{
vuint8 lDTC[3];
DescMsgLen freeSpace;
/* Check if enough space is free in ring-buffer */ freeSpace
= DescRingBufferGetFreeSpace();
if (freeSpace
>= 3)
/* try to read from EEPROM */ {
/* Success - result is in lDTC */ DescRingBufferWrite(pMsgContext
->iContext, &lDTC, 3);
}
else {
/* nothing to do, wait for next MainHandler call, ring-buffer is full */ }
}
13.7 …prevent the ECU going to sleep while diagnostic is active Most car manufactures have the requirement to keep the ECU alive while the diagnostic
layer is active; including a pending request or a non-default session is currently active.
This requirement is handled by CANdesc for some car manufactures (see OEM specific
TechnicalReference_CANdesc document for details)
The following code example shows all necessary steps to keep the ECU alive while
diagnostic jobs are running (e.g. non-default session):
{
DescContextActivity lActivity;
2015, Vector Informatik GmbH
Version: 3.09.00
149 / 158
based on template version 5.1.0
Technical Reference CANdesc
DescStateGroup lState;
lAcitvity = DescGetActivityState();
lState = DescGetStateSession();
/* check for a pending request or a non-default session */
if ( ((lState & kDescStateSessionDefault) == 0) ||
(lActivity != kDescContextIdle) )
{
/* Force to stay alive */
}
else
{
/* Ready for sleeping */
}
}
13.8 …send a positive response without request after FBL flash job According to some specifications the application has to send a positive response either to
“diagnostic session control – default session” or “ECU reset – hard reset” after a
successful flash job without a request. The Flash Boot Loader has to set a flag (reset
response flag) in RAM or EEPROM which has to be evaluated by the application at
startup. Depending on its value the application has to call the CANdesc function
DescSendPosRespFBL() with the appropriate response ID.
CANdesc provides the AP
I DescSendPosRespFBL() for this purpose.
Due to bus communication is necessary to send the positive response; some limitations
have to be handled by the application:
1) Bus communication is to be requested by the application
2) If bus communication is possible, the application has to call
DescSendPosRespFBL().
CANdescBasic will send the positive response.
3) The application will be called
(ApplDescInitPosResFblBusInfo()) to provide the concrete
addressing information of the response.
4) Bus communication can be released by the application.
13.9 …enforce CANdesc to use ANSI C instead of hardware optimized bit type CANdesc uses per default the bit-type definition provided by the CANdriver, since it is
selected as optimal for the concrete CPU. On this way the CANdesc ROM and RAM
resource consumption is kept as low as possible.
Due to the complexity of some CANdesc data structures there can be problems on certain
compilers with special bit-structure compiler options.
If you encounter such problems either at compile or at run-time, you can turn the ANSIC C
bit-type support in CANdesc on. To do that, just add a user configuration file in GENy with
the following content:
#define DESC_USE_ANSI_C_BIT_TYPE
2015, Vector Informatik GmbH
Version: 3.09.00
150 / 158
based on template version 5.1.0

Technical Reference CANdesc
13.10 …configure Extended Addressing If Extended Addressing is used as TP Addressing mode some additional settings have to
be done. “
DescCheckTA” has to be set for the “
Target Address Message Filter” in GENy.
Figure 13-1 GENy TP configuration
Additional a user configuration file has to be used to configure the functional target
address. An example for the content of the user configuration file is given below.
#define kDescOemExtAddrFuncTargetAddr 0xFE
13.11 …use Multiple Addressing This chapter is a short summary of additional information that the application has to
provide for CANdesc if the Tp addressing mode is Multiple Addressing.
In the case that a positive response has to be send after FBL flash job of the application,
please assure that the correct addressing information are provided in the callback
ApplDescInitPosResFblBusInfo(). Furthermore, the “Rx Get Buffer” and “Rx Indication” functions have to be redirected to the
application if one of the Tp Addressing modes is Normal Addressing. This can be done in
the GENy configuration of the TP, a callback name different from the one that is
implemented in CANdesc has to be entered.
2015, Vector Informatik GmbH
Version: 3.09.00
151 / 158
based on template version 5.1.0

Technical Reference CANdesc
Figure 13-2 GENy TP callbacks
The callbacks have to be implemented in the application. In the Get Buffer function the
CAN Id has to be set for the FC in the case of Normal Addressing,
/* Example: A configuration with only CANdesc Tp connections and only one Tp
Tx/Rx channel. */
TP_MEMORY_MODEL_DATA canuint8* DispatcherDescGetBuffer(canuint8 tpChannel,
canuint16 datLen)
{
TP_MEMORY_MODEL_DATA canuint8* retPtr = V_NULL;
retPtr = DescGetBuffer(tpChannel, datLen);
if(retPtr != V_NULL)
{
if((TpRxGetAddressingFormat(tpChannel) == kTpNormalAddressing))
{
/* kApplNormalAddressingTxId, have to defined by the application*/
TpRxSetTransmitID(tpChannel, kApplNormalAddressingTxId);
}
}
return retPtr;
}
The response ID for Normal Addressing has to be set in the Indication function. The
response Id has to be set after the call of
DescPhysReqInd(). /* Example: A configuration with only CANdesc Tp connections and only one Tp
Tx/Rx channel. */
2015, Vector Informatik GmbH
Version: 3.09.00
152 / 158
based on template version 5.1.0

Technical Reference CANdesc
void DispatcherDescPhysReqInd(canuint8 tpChannel, canuint16 datLen)
{
vuint8 addressingType = (TpRxGetAddressingFormat(tpChannel));
DescPhysReqInd(tpChannel, datLen);
/*Set CAN IDs for the Response*/
if(addressingType == kTpNormalAddressing)
{
/* kApplNormalAddressingTxId and kApplNormalAddressingPhysRxId, have to defined
by the application*/
TpTxSetChannelID(0 /*tpTxChannel*/, kApplNormalAddressingTxId,
kApplNormalAddressingPhysRxId);
/* tpTxChannel = 0 is only possible because only one Tx Channel is configured.*/
}
}
13.12 …use “Dynamic Normal Addressing Multi TP” with multiple tester This chapter is a short summary of additional information that the application has to
provide for CANdesc if the Tp addressing mode is “Dynamic Normal Addressing Multi TP”
with more than one tester.
In the case that a positive response has to be send after FBL flash job of the application,
please assure that the correct addressing information are provided in the callback
ApplDescInitPosResFblBusInfo(). Furthermore, the “Rx Get Buffer” function has to be redirected to the application. This can
be done in the GENy configuration of the TP, a callback name different from the one that is
implemented in CANdesc has to be entered.
Figure 13-3 GENy TP callbacks (physical addressing)
2015, Vector Informatik GmbH
Version: 3.09.00
153 / 158
based on template version 5.1.0

Technical Reference CANdesc
The “Get Buffer” function of the functional connection has to be redirected to the
application too.
Figure 13-4 GENy TP callbacks (functional addressing)
The callbacks have to be implemented in the application. The received CAN ID has to be
mapped to the corresponding transmit CAN ID and the TP connection number has to be
set in the xxxGetBuffer callback:
TP_MEMORY_MODEL_DATA canuint8* DispatcherDescGetBuffer(canuint8 tpChannel,
canuint16 datLen)
{
TP_MEMORY_MODEL_DATA canuint8* retPtr = V_NULL;
switch(TpRxGetChannelID(tpChannel))
{
case kDispatcherRxDiagPhysCanId:
TpRxSetTransmitID(tpChannel, kDispatcherTxDiagPhysCanId);
TpRxSetConnectionNumber(tpChannel, kDescDiagConnection);
retPtr = DescGetBuffer(tpChannel, datLen);
break;
case kDispatcherRxDiagAddPhysCanId:
TpRxSetTransmitID(tpChannel, kDispatcherTxDiagAddPhysCanId);
TpRxSetConnectionNumber(tpChannel, kDescDiagAddConnection);
retPtr = DescGetBuffer(tpChannel, datLen);
break;
default:
;
}
return retPtr;
}
The receiced CAN ID has to be mapped to the corresponding transmit CAN ID in the
xxxGetFuncBuffer callback. Furthermore it is important, that the physical Rx ID is set for
the response and not the functional one. This CAN ID is used to recognize the FC of the
tester in case of a multiframe response:
TP_MEMORY_MODEL_DATA canuint8* DispatcherDescGetFuncBuffer(vuint16 dataLength)
{
TP_MEMORY_MODEL_DATA canuint8* retPtr = V_NULL;
switch(TpFuncGetReceiveCanID())
{
case kDispatcherRxDiagFunc:
TpFuncSetTransmitCanID(kDispatcherTxDiagPhysCanId);
TpFuncSetReceiveCanID(kDispatcherRxDiagPhysCanId);
2015, Vector Informatik GmbH
Version: 3.09.00
154 / 158
based on template version 5.1.0
Technical Reference CANdesc
retPtr = DescGetFuncBuffer(dataLength);
break;
case kDispatcherRxDiagAddFunc:
TpFuncSetTransmitCanID(kDispatcherTxDiagAddPhysCanId);
TpFuncSetReceiveCanID(kDispatcherRxDiagAddPhysCanId);
retPtr = DescGetFuncBuffer(dataLength);
break;
default:
;
}
return retPtr;
}
The code examples above are for 2 testers, in the example are some defines used that
have to be provided by the application corresponding to the configuration.
Define Description kDispatcherRxDiagPhysCanId
Physical request CAN ID of the first tester
kDispatcherRxDiagFuncCanId
Functional request CAN ID of the first tester
kDispatcherTxDiagPhysCanId
Response CAN ID of the first tester
kDispatcherRxDiagAddPhysCanId
Physical request CAN ID of the second tester
kDispatcherRxDiagAddFuncCanId
Functional request CAN ID of the second tester
kDispatcherTxDiagAddPhysCanId
Response CAN ID of the second tester
kDispatcherTxDiagTpChannel
Transmit Tp Channel of CANdesc. If only one
Tp Channel is used, it is has to be set to zero.
2015, Vector Informatik GmbH
Version: 3.09.00
155 / 158
based on template version 5.1.0
Technical Reference CANdesc
14 Related documents Abbreviation File Name Description /KWP2000/
Keyword 2000 protocol
/TPMC/
User manual of the multi-connection
transport layer module. The transport
layer is implemented according to /ISO
15765/
/ISO 15765/
This ISO standard describes diagnostics
and diagnostics on CAN.
/AN-IDG-1-013/ AN-IDG-1-
Application note for CANdela Studio on
013_How_to_Specify_ how to configure OBD service 0x06.
OBD_Service_06.pdf The application note is available in the
download center on our homepage.
Note: If no file name is given, the document is not provided by Vector.
2015, Vector Informatik GmbH
Version: 3.09.00
156 / 158
based on template version 5.1.0
Technical Reference CANdesc
15 Glossary Abbreviation Description
CANdb CAN data
base by Vector which is used by Vector tools.
CANdesc CAN diagnostics
embedded
software
component
CDD CANdela
Diagnostic
Database
CF Consecutive
Frame (transport protocol frame)
CCL Communication
Control
Layer
DBC CAN database format of the Vector company, which is used by the
GENtool to gather information about the ECUs in the network, their
communication relations, message definitions, signals of
messages, network related information (e.g. manufacturer type,
network management type, etc.).
ECU Electronic
Control
Unit
FBL Flash
Boot
Loader
KWP 2000 Key
word
Protocol
2000 OSEK German abbreviation, “
Offene
Systeme und deren Schnittstellen
für die
Elektronik im
Kraftfahrzeug”, means “open systems and the
corresponding interfaces for automotive electronics”
RCR-RP Request
Correctly
Received
– Response
Pending
SF Single
Frame
SID Service
Identifier
SPRMIB Suppress
Positive
Response
Message
Indication
Bit
TP Transport
Protocol
UDS Unified
Diagnostic
Services
VSG Vehicle
System
Group
2015, Vector Informatik GmbH
Version: 3.09.00
157 / 158
based on template version 5.1.0
Technical Reference CANdesc
16 Contact Visit our website for more information on