DaVinci Configurator Pro Release Notes

DaVinci Configurator Pro Release Notes

Copyright © 2008-2014 by Vector Informatik GmbH

Table of contents

DaVinci Configurator Pro 4.2 SP2
DaVinci Configurator Pro 4.2 SP1
DaVinci Configurator Pro 4.2
Additional Information
Older DaVinci Configurator Pro Releases

DaVinci Configurator Pro 4.2 SP2

New features

  • 'Compare To...' is available for DaVinci Configurator Base if SIP contains valid RTEConfigurator license
  • Reworked 'Compare To...' algorithm and display
    MICROSAR Generator
  • New commandline options '-CondGen' and '-noCondGen': Enable/disable conditional generation of files

Fixed issues

  • Trying to remove Containers results in access violation
  • Validation may lead to crash if JumpTo target is not available
  • Evaluating 'active' state of GENy-modules may not work correctly for splitted DPA projects (rework of algorithm)
  • 'Compare To...' of single module configuration does not work (for splitted DPA projects)
  • Saving large project fails due to 'out-of-memory' exception
    MICROSAR Generator
  • Creating converted ECUC ecuc file for several external Generators now correctly gathers all required module configurations
  • Running multiple instances at once fails due to 'incorrect' file locks
  • Converting ecuc file to different AUTOSAR revision removes MODULE-DESCRIPTION-REF

(top)

DaVinci Configurator Pro 4.2 SP1

New features

  • 'Compare To...' now may also be triggered from command line by using new '-mergeWith <other-project>' option
    MICROSAR Generator
  • Prevent generation of empty 'Licensee' information

Fixed issues

  • Preconfigured containers of EepAt25128 will not be shown and generated correctly
  • ECUC-lock is not retrieved after generation process
  • Xslt transformation creates 'invalid' UTF-8 document
  • Module definition with empty LONG-NAME node results in crash
    MICROSAR Generator
  • Incomplete validation if commandline option '-m' contains module definition reference

(top)

DaVinci Configurator Pro 4.2

New features

  • Extend 'Compare To...' with side-by-side comparison of module configuration
  • Extend 'Compare To...' with partial or complete merge of module configuration
  • Enable drag-and-drop to compare project or module configuration via file dropping
  • Support Configurator 5 related packages
  • Support AUTOSAR 3.2.2 specification
  • Support AUTOSAR r4.0 specification
    MICROSAR Generator
  • New commandline option '-syncmem': Calculate of all memory block attributes and save configuration
  • New commandline option '-remPreCfg': Remove PreConfiguration for specified module(s)
  • New commandline option '-version': Provide parameter to get version string of running microsargen
  • New commandline option '-noxsd': Skip project file from AUTOSAR schema validation
  • Commandline option '-m' supports specification of module definition reference e.g. '-m /MICROSAR/Ea' instead of '-m Ea'
  • Calculate /MICROSAR/Ea and /MICROSAR/EaBasic/Ea block attributes before validation within AUTOSAR 4 environment

Fixed issues

  • 'Compare To...' lists differences for unchanged module configuration
  • 'Compare To...' does not handle dpa files
  • Floating license will sometimes not be recognized
  • Removing preconfigured configuration do not remove preconfigured container itself
  • Loading project sometimes creates duplicates of nested container objects
  • JumpTo functionality of message window may lead to crash
  • Import of references fails if AR-PACKAGE uses same short-name as module configuration
  • 'Import/Append' do not derive shortnames for all appended container objects
  • Creating module instances in architecture view may result in errors and error messages
  • Closing application prints wrong message of 'Running Recorder within dongle installation
  • :
  • Keyman Dongle stalls application with different USB devices
  • Exception on loading project with WdgIf config within AUTOSAR 4 environment
  • Wrong display of reference value in WdgRef if referring to other Wdg instance than Wdg
  • Loading project prints wrong warning 2102 'Cannot load data of [..] no definition found in definition file(s) in some cases
  • UPPER-MULTIPLICITY-INFINITE fails for '0'/'1' values within AUTOSAR4 environment
  • Print warning if 'Unlock configuration' is removed for read-only module in architecture view
  • Refresh Log folder in project explorer to display 'Import-LogFile' at the end of import process
  • The load of a definition file set of modules with same name but in different sub-Packages is not executed correctly
  • A preconfigured value is changed by a recommended value in some rare cases
  • Find parameter with option 'Name' does not show the value of the parameter in the result list
  • Value of enum literal of SpiPrearrangedBus is changed just by entering control
  • Ea validation prints wrongly error message with Erase Unit size (V005)
  • Parameter help window does not show complete description text on japanese WinXP
    MICROSAR Generator
  • EcuM generator prints wrong error message for missing preconfigured configuration of CanTrcv_Generic1CanDio
  • Extend -p option with printing AUTOSAR namespace information in project header
  • New commandline arguments for -save, -syncmem and -remPrfg missing in -? option
  • Dependencies are sometimes not recognized for AUTOSAR4 definition files

(top)

Additional Information

Copyright

© Vector Informatik GmbH

Certified Quality Management System

The Quality/Process Management of Vector Informatik GmbH is being certified according to DIN EN ISO 9001:2000-12 (formerly DIN EN ISO 9001:1994-08) throughout since 1998-08-19.

Vector Informatik GmbH - Addresses

Vector Informatik GmbH
Ingersheimer Str. 24
D-70499 Stuttgart, Germany
Phone: +49 711 80670-0
Fax: +49 711 80670-111
info@de.vector.com
https://vector.com

Subsidiaries

Vector Austria GmbH
Millennium Tower, Etage 41
Handelskai 94-96
1200 Vienna
Austria
Phone: +43 1 90160-0
Fax: +43 1 90160-35
info@at.vector.com
http://www.vector-austria.com

Vector Automotive Technology (Shanghai) Co., Ltd.
Sunyoung Center
Room 1601-1603, No.398 Jiang Su Road
Changning District
Shanghai 200050
China
Phone: +86 21 6432 5353-0
Fax: +86 21 6432 5308
info@cn.vector.com
http://vector-china.com

Vector France S.A.S.
168, Boulevard Camélinat
92240 Malakoff
France
Phone: +33 1 423140-00
Fax: +33 1 423140-09
information@fr.vector.com
http://vector-france.com

Vector GB Ltd.
Rhodium
Central Boulevard
Blythe Valley Park
Solihull, Birmingham
West Midlands B90 8AS
United Kingdom
Phone: +44 121 50681-50
Fax: +44 121 50681-69
info@uk.vector.com
http://www.vector-gb.co.uk

Vector Informatik India Pvt. Ltd.
4/1/1/1, Sutar Icon, Sus Road
Pashan, Pune - 411 021
India
Phone: +91 20 2587-2023
Fax: +91 20 2587-2025
info@in.vector.com
http://www.vector-india.com

Vector Japan Co., Ltd.
Tennozu Yusen Bldg. 16F
2-2-20 Higashi-shinagawa, Shinagawa-ku
Tokyo 140-0002
Japan
Phone: +81 3 5769-7800
Fax: +81 3 5769-6975
info@jp.vector.com
http://www.vector-japan.co.jp

Vector Korea IT Inc.
Gomoas Bldg. 5F
12 Hannam-daero 11-gil Yongsan-gu
Seoul 140-889
Republic of Korea
Phone: +82 2 8070-600
Fax: +82 2 8070-601
info@kr.vector.com
http://www.vector-korea.com

VecScan AB
Theres Svenssons Gata 9
417 55 Gothenburg
Sweden
Phone: +46 31 76476-00
Fax: +46 31 76476-19
info@se.vector.com
http://www.vecscan.com

Vector CANtech, Inc.
39500 Orchard Hill Place
Suite 550
Novi, Michigan 48375
USA
Phone: +1 248 449-9290
Fax: +1 248 449-9704
sales@us.vector.com
http://www.vector-cantech.com

(top)

Older DaVinci Configurator Pro Release Notes

Copyright © 2008-2014 by Vector Informatik GmbH

(main overview)

Table of contents

DaVinci Configurator Pro 4.1 SP1
DaVinci Configurator Pro 4.1
DaVinci Configurator Pro 4.0 SP6
DaVinci Configurator Pro 4.0 SP5
DaVinci Configurator Pro 4.0 SP4
DaVinci Configurator Pro 4.0 SP3
DaVinci Configurator Pro 4.0 SP2
DaVinci Configurator Pro 4.0 SP1
DaVinci Configurator Pro 4.0

DaVinci Configurator Pro 4.1 SP1

New features

  • Print 'display name' of configuration entity created from long-name definition in GCE, parameter help window...
  • Allow user to switch between LongNames and ShortName in GCE
  • Extend auto-set mechanism for enumeration parameters with one literal
  • Extend Gce with comment column to ease usage of comments
  • Add 'Create desktop shortcut' of current project to main menu
  • Provide new menu items of context menu in project explorer for all actions that are project-relevant
  • Show definition references in module list of project options
  • Support new license dongle (Vector Keyman)
  • Enable dll-lock-mapping for GENy-modules Eth, EthIf, EthSm, EthTrcv
  • Support AUTOSAR 3.2.2 specification
    MICROSAR Generator
  • Provide $(DpaProjectFile) variable in external generator settings
  • Generation of %.Object% does no longer work correctly for each case
  • Generation of %.AbsoluteTargetDir% and %.TargetDir% does no longer work
  • Generationg with -m IoHwAbstraction fails with 'no definition found...' error message
  • Misleading message of 'No license found for module 'Dio'' on starting generator with -m Dio option corrected
  • Generating EcuM prints error message regarding to missing Mcu param

Fixed issues

  • First column is set read-only sometimes
  • Exception on parsing SIP with corrupted file structure
  • Reference to inactive module may lead to crash when loading project
  • Missing online help for license manager
  • Issue with update of modified data on saving project
  • Wrong position of 'delete block' button in NvM blockdescription table
  • Emphasize is not shown with related editor frame in time
  • Recommended configuration for ForeignReference is not considered correctly
  • Reloading reference value fails sometimes
  • Splitted ECUC file - Board will be removed from EcuConfiguration/ModuleRefs list
  • JumpTo does not focus GCE if selected parameter is not found in comfort view
  • Empty arxml file will be saved for SIP with non-AUTOSAR-modules
  • Compare To... displays current project filename instead selected one
  • BSW-Implementation dialog does not show version information for AUTOSAR 4.0
  • Recommended configuration and Preconfiguration are not applied correctly for AUTOSAR 4.0
  • Use of JumpTo-functionality may result in crash

(top)

DaVinci Configurator Pro 4.1

New features

  • Improved performance when showing tables with complex configuration tasks
  • Improved handling of 'Find Configuration Entity' dialog
  • SSWC files will be removed if 'Use RTE' switch is not set in according BSW module
  • New menu 'Project/Compare To...' with report of changes between current ECUC and stored or selected one
  • New 'intelligent' Import/Update option
  • Logfile for Import/Update and Import/Append
  • Distribute new version of Vector License Manager
  • GCE view can toggle between displaying ShortNames or LongNames of parameters and references
    MICROSAR Generator
  • Support AUTOSAR 4.0 (without VARIATION-POINT handling)

Fixed issues

  • LongName of parameter definition overrides user-defined editor labels
  • Table shows wrong values on related panels in OS task configuration, table content on page will not be properly updated
  • First column of tables is initially locked
  • Module configuration editor is not available for just-activated modules
  • Scrollbars are not shown sometimes
  • JumpTo-functionality shows Hint-Arrow before jumping to correct page
  • Other Vector Tools get lock for ECUC file although value was modified
  • Hex/Dec button does not change format
  • Labels are sometimes missing (Win7)
  • Handling of AUTOSAR Stub-Configuration does not work correctly for splitted DPA projects
  • Class PreConfiguration locks wrong cells in table
  • Import/Append only works once (without reloading project)
  • Automatic reference update does not work in some cases
  • BSW-Implementation dialog does not show 'Requires' correctly for 'Multi-Package' module definitions
  • Dirty-flag will be set if comfort view of module is opened
  • 'Find Configuration Entity' dialog will crash if values are deleted while it is opened
  • Sorted table sometimes changes order of rows if table is not sorted by unique values
  • Default value will not be set for Multiline-String-Parameter
  • ReadOnly mode for GENy components locks 3rd party components
  • Main menu '?/Samples' shows too many entries
  • Labels overwrite other controls (preventing e.g. access of selection controls)
  • Reference to inactive Module may lead to crash when loading project
    MICROSAR Generator
  • Generator-call for complex device drivers will not be loaded correctly from Identifier.xml
  • GenRule Type IncludeList does supports multiple values for expression %Identifier.Object/Parameter%

(top)

DaVinci Configurator Pro 4.0 SP6

New features

  • Support AUTOSAR 3.2.1 specification
  • ReadOnly mode for GENy components (with each project handling current state of 'lock' itself)
  • Recorder for ECUC changes
  • Create a stripped down package with information for support requests
  • Support sorting according to SymbolicNameValue in GCE view
  • Change order of containers in GCE view with MoveUp and MoveDown option
  • Support extended filter functionality in all combobox columns of tables
  • 1st Level Validation should be executed completely and independent of existance of Validation.xml
  • Improved performance for loading and saving large ECUC files
  • Improved performance for applying PreConfiguration and Recommended Configuration
  • Improved performance for opening/switching view with extensive Actions
  • New option '$(Package)' for external tools
  • Allow saving a 'purged' configuration of modules (= without PreConfiguration) into ECUC file
  • Provide 'Find Entitiy ...' as toolbar icon of project explorer for quick access
  • Provide quick access to module preferences in context menu of architecture
  • Harmonisation of ECU contents (for float values and empty elements) with GENy and DaVinci Developer
  • Results of 'Detect Unresolved References' now support Jump-To-Error feature
    MICROSAR Generator
  • Omit printing the same (Validation) message too often
  • Use only required modules for conversion of ECUC file to different AUTOSAR revision, not complete ECUC file

Fixed issues

  • F6 key support for opening special dialogs does not always work
  • Architecture 'Compare To ...' dialog mixes 'shown' and 'to-be-saved' values of parameters
  • Package license does not work if UNC-notation is used for path definition
  • Unexpected windows sound on field editing
  • XCopy Installation raises wrong 'No controller information available in ...' error message
  • Correct license activation is not recognized in rare cases
  • Starting with dpa-file for invalid package license results in access violation
  • MODULE-DESCRIPTION-REF is not written into ECUC file
  • F5 key creates new values for some parameters and references
  • Validation with external tools does not work for splitted ECUC
  • Merged ECUC file for external tools uses wrong AUTOSAR revision
  • Scrollbars are not shown if not all input fields fit on view of module
  • Default value is shown in View but will not be saved
  • Reference targets will not be found in Group which uses SUB-PACKAGES in module definition
  • Labels are missing sometimes when using Windows 7
  • 'Not empty' check will not be executed correctly for Identifiers of new Container
  • Some Containers are not selectable in GCE view
  • Access violation may occur when deleting UserBlocks in NvM
  • ComSignals can be added while in ReadOnly mode
  • Context menu does not show correct types of Sub-Containers in GCE view
  • After Validation parameter help window does no longer work correctly
  • Splitter above table is not shown correctly
  • Architecture is empty when closing and reopening it
  • PrettyPrint of ECUC file invalidates empty VALUE-REF nodes
  • Minimum relation of Containers is not considered correctly when creating new project
  • DaVinci Project Assistant does not get ECUC-lock when started from 'File/Project Assistant/Project Settings...'
  • PreConfiguration and Recommended Configuration for reference values is not applied correctly
  • Recommended Configuration and Recommended Class Configuration are not applied correctly for ConfigurationSets
  • Creating 'Dem Events' in 3rd party Dem fails
  • Cascaded Preconfigured Class Configuration and Recommended Class Configuration are not applied correctly
  • Automatic update of Reference values does not work correctly in some cases
  • Values of Instance-References are not loaded
  • 'Del' key is working in locked GCE view
    MICROSAR Generator
  • Generation of WdgIf fails for values of WdgExt
  • Commmandline Generation does not accept different camelcase spelling of module
  • XSL-Generation does not work for splitted ECUC

(top)

DaVinci Configurator Pro 4.0 SP5

New features

  • Support of multi selection with bulk change in GCE and tables
  • AutoComplete and extended search functionality for dropdown lists
  • Enhanced usability in dialog for editing references
  • New validation and generation dialog
  • New 'Compare To...' feature in architecture view with possibility to create a simple report for all changed entity values
  • Introducing new naming 'Code Templates' for user changeable files
  • New project on welcome screen now starts DaVinci Project Assistant
  • The sort order of items in GCE view can be configured
  • The parameter information dialog shows the LONG-NAME of a selected entity
  • Support of simple html tags (<b>, <i>, <u>) in control tooltip
  • Integer values can be displayed in binary format (optional as replacement to dec/hex display)
  • Support of unsigned 64-Bit integer values
  • Create a report which contains all changed entity values
  • Parse package license folder automatically (without usage of System.xml)
  • Improved handling of large Windows fonts (120 dpi)
  • Recalculate derived parameters after opening ECUC file
    MICROSAR Generator
  • Switch for conditioned generation becomes project-specific

Fixed issues

  • Show tooltip and parameter information for locked parameters in comfort perspectives
  • Import of Foreign-References does not work correctly (DEST-attribute is not imported)
  • Cryptic error messages if XML schemes are locked by a different tool
  • ImplementationVariant of ECUC file is not considered
  • ActionLists should be executed only within 'own' instance
  • Invalid data of control is not 'ignored' correctly
  • GCE view does not show current instance
  • Performance problem on opening Tools/Preferences dialog with a large set of modules
  • Recommended value information is not displayed correct
  • Identifier function '.Object' does not work if a different module is referenced
  • Parameter information is not shown properly if control affects other controls
  • Imported module configuration does not use AR-PACKAGE of ECUC file
  • Order of module configurations in ECUC file is changed on saving
  • Import does not work for inactive module
  • 3rd party modules are not shown in Tools/Preferences dialog if home folder is invalid
  • Saving large ECUC file fails
  • Modules without comfort view are not shown in project explorer
  • Splitted ECUC will not be saved correctly
  • PrettyPrinting of ECUC file differs from PrettyPrinting done by GENy
  • Adding comments results in 'corrupted' ECUC file
  • Automatically created ValueList does not work correctly if literals in module definition use LONG-NAME
  • Change detection does not work correctly for splitted ECUC
  • PreConfiguration of Containers without childs-Values does not work
  • Parameters set for Pre- or PostGeneration cannot be saved
  • Modules 'renamed' in Identifier.xml (e.g. IoHwAb) will not work correctly for DPA project
  • References to 'not-standard-AUTOSAR' modules will not work correctly for PreConfiguration
  • ValueLists on related Panels of table will not be updated
  • The option 'Select Values...' in comfort view does not work
  • Copying Containers does not copy sub-Containers correctly (if their MinRelation is larger than 1)
  • When creating Containers the MinRelation of sub-Containers sometimes is not considered correctly
  • Certain Containers are not shown in GCE view
  • Modules not available in DaVinciCFG will be deleted from ECUC file
  • Splitted ECUC using different AUTOSAR revisions results in errors
  • Importing module configurations into splitted ECUC does not work
  • Saving when closing splitted ECUC may invalidate main splitter
    MICROSAR Generator
  • Parameter '$(GenDataFolder)' will not be passed correctly to external generator

(top)

DaVinci Configurator Pro 4.0 SP4

New features

  • Windows 7 support
  • Multi-User support with splitted ECUC
  • Generate output only if related configuration is modified (switchable in Tools/Preferences)
  • Consider MinRelation of Sub-Containers, Parameters etc when creating new Container
  • PreConfiguration will be applied to multiple instances of a module
  • Internal name of module supports underscores (Note: If internal module name contains underscores, Identifier-notation may not be used for this module)
  • View Tab names of instanceable modules are simplified
    MICROSAR Generator
  • Start validation with xsd validation

Fixed issues

  • Checkboxes without value are not shown correctly in tables
  • Scrollbars are not shown correctly for large Panels of TableFrame
  • BSWMD files containing multiple xml-namespaces result in access violation
  • Loading project with TargetFolders set for DaVinci Project Assistant can result in stack overflow
  • PreConfiguration is not entered at correct position when loading ECUC files
  • Screen starts to flicker during extensive actions
  • ValueLists show Containers of inactive modules
  • ShortName of module configuration is fixed if PreConfiguration is used
  • 'Save' is disabled although module configuration was changed during loading
  • Sorted table shows wrong value on related Panels
  • Handling of instancable modules
  • 'Recent Projects' list is not shown at correct position on japanese Windows XP
  • References were not updated correctly if target module was renamed
  • 'Revert To Initial Values' in Architecture can sometimes result in access violation
  • Access to not existing optional parameter results in index out of bounds exception
  • 'Extended' xsd-check (= ShortNames may have up to 128 chars) reports errors for long reference values
  • 'Undefined' checkboxes are not shown correctly for related Panels of TreeFrames and TableFrames
  • Controls are not enabled correctly on Os-view
  • MinRelation of Containers, Parameters etc is considered before loading a project instead of after loading it
  • Switching pages in comfort view can result in access violation
  • When switching pages in GCE view sometimes certain values are not shown correctly
  • Selected Choice Containers are not loaded correctly if lower multiplicity is set wrong in module definition
  • In some cases multiple configuration container is not shown correctly in TreeFrame
  • Update module configuration when saving ECUC after 'Revert To Initial Values' was used
  • Saving ECUC fails due to unexplained reason
  • Wrong context is used in ActionLists and for enabling Controls

(top)

DaVinci Configurator Pro 4.0 SP3

New features

  • Support of Fold Containers in GCE to enhance clarity of GCE tree
  • Support of Cut, Copy and Paste of containers in GCE
  • Create validition log file in XML format where all executed validation rules are signed per ID with status OK or NOK
  • Support use of variable names in folder specifications
  • Extend parameter context menu with new item to undefine a parameter
  • Enhance usability of assigning package license to projects
  • Provide new menu item in Architecture view to revert module configuration to default with optional Recommended Configuration
  • Enhance performance on loading projects and module editors
  • Extend find parameter dialog with possibility to search for parameter comments
  • Extend table context menu to insert or delete selected row
  • Extend project menu with new item to test multiple configuration container names for uniqueness
  • Read and write ECUC files with more than one AR-PACKAGE
  • Support message numbers in all user messages
  • Close nested messages automatically if they only contain uncritical severity messages
  • Harmonize XSD validation with possibility to ignore ShortName length violation
  • Extend message context menu with item to open files with unknown file association
  • Support AUTOSAR 3.0 Rev6 and 3.1 Rev4
  • Support bit-operations in formula descriptions
  • Status line reworked for better understandability
  • Consider MinRelation of Containers, Parameters etc when creating new project
    MICROSAR Generator
  • Generation.log file format changed to XML
  • Print user notification in module selection dialog for dependencies of modules that become deactivated
  • Support starting generator with dpa-file
  • Provide option to switch off the creating of *.bak files during generation
  • Save user code from Removed Code Area on restart of generation process

Fixed issues

  • The parameter help window is empty after insertion of a new row in a table
  • The range of integer or float param is not displayed in the parameter help window
  • Wrong short cut description in context menu for parmeter help found (should be Shift+F1)
  • The project explorer becomes not synchronized in some case
  • Set value to default fails with wrong pasted text in some case
  • Jump-To-Error fails in some cases
  • ECUC change detection shall not be executed if application is not focused
  • Error messages of 3rd party generators are not well-formed if project path contains blank char
  • Button for Hex/Dec format wrongly stays disabled in some case
  • Access violation when changing editors in some case
  • ECUC pretty print becomes not well-formed in some case
  • Path specifications containing '#' cause errors on creating editors
  • Tooltips are sometimes not readable
  • An existing Recommended Configuration is not considered when a module is added to the project
  • ShortName naming algorithm skips free numbers
  • DaVinci Project Assistant does not save ECUC before "update ecuc project..." is executed
  • The error Messages raised from DaVinci Project Assistant are not displayed completely
  • Loading a file can 're-enter' optional Containers
  • Saving fails if 'MSXML 6.0 SP2' is used
  • Performance issue when opening large comfort views
    MICROSAR Generator
  • Parameters $(EcucFile) and $(EcucFolder) are passed incorrectly to external Validator/Generator if 'Supply AUTOSAR Revision' option is used
  • Relative project paths specified by DaVinci Project Assistant are not generated to the correct folder

(top)

DaVinci Configurator Pro 4.0 SP2

New features

  • Display names of module perspectives in project explorer
  • Usage of license.bin becomes obsolete
  • Support PreConfigured and Recommended Class Configuration
  • The display format of Integer parameters can be changed by user to decimal, hex or binary format
  • Support GENy dll for generation of SWC
  • Full integration of new Project Assistent in user interface
    • Create new ECUC project based on system extract
    • Update current ECUC project with new modified system extract
    • Edit common project settings
  • Establish context menu for each parameter to support actions to
    • add or modify a comment string
    • reset the parameter value to the specified default value
    • reset the parameter value to the specified recommended value
    • open a popupwindow with all information raised from definition
  • Support AUTOSAR release 3.1 (together with accrued patch releases 3.0.3, 3.0.4, 3.1.1, 3.1.2)
  • Support usage of identifier.xml to cover extensions of AUTOSAR specification
  • Support derived parameter types with Vector formula description
  • Support concurrent ECUC access between MICROSAR tools
    MICROSAR Generator
  • Restrict loading to necessary dependent BSW modules to enhance performance

Fixed issues

  • Missing external generator will not be reported
  • Renaming SymbolicNameRef parameter results in invalid value
  • If an existing but invalid package license entry is found in any project, the project will not be loaded
  • Save module configuration to ECUC only if really changed
  • Deactivating modules does not work in some cases
  • Parsing definition files fails sometimes if additional files found e.g. /bswmd/project.pj
  • ECUC change detection hangup in a special environment
  • The mousepointer will not be set back to default on leaving project explorer
  • Relative paths are resolved not relative to project folder
  • Import Append fails sometimes
  • Context menu item 'Jump To ...' becomes not enabled
    MICROSAR Generator
  • Calling external generator removes foreign created temp files

(top)

DaVinci Configurator Pro 4.0 SP1

New features

  • Provide finding AUTOSAR objects in current configuration
  • Provide new menu item to launch GENy with current project configuration
  • New message register 'Result List' for a message summary grouped by message type
  • Provide new context menu item in architecture for validating module definition file(s)
  • Provide new context menu item in architecture for importing module configuration with replace or append option
  • Provide new context menu item in architecture for opening user added documents
  • Display user notification if current ECUC file is changed from other application (Change Detection)
  • Display dependencies between modules in implementation help window
  • Display AUTOSAR origin, derivation and destination reference in parameter help window
  • Provide new context menu to close selected tab or all tabs except selected one
  • Print warning message on loading a module configuration with a different definition reference except standard definition reference
  • Assign vendor-specific definition on loading a module with a standard AUTOSAR definition
  • Validation of a module can be performed completely and without breaking on first error
  • Provide new menu item to verify UUID values of current project
  • Improvement on calling GENy generator
  • Provide special GCE view for Com- and IPduSignals
  • Provide new .profile setting to launch associated application after creating a report file
    MICROSAR Generator
  • Support -tswc command line option to set directory name for generated SWC description files
  • Support -tuser command line option to set the target directory name for generated user-changeable files
  • Support -h command line option for help
    DaVinci Difference Viewer
  • Display of semantic differences between AUTOSAR XML files
  • Supports System Description files, SWC Description files and ECU-C files
  • Integrated into Windows Explorer context menu for files with extension .arxml

Fixed issues

  • Extend handling of undefined boolean parameter values
  • 3rd party generator cannot be started if its working directory contains blanks in path specification
  • 3rd party modules are not shown sometimes in project explorer
  • Wrong architecture mapping for FEE module
  • Create tooltip and Ctrl-F1 to access parameter information for locked parameters in GCE mode
  • Redesign of register 'Changes' in message window
  • Different display of messages, no multiple-selection of messages, missing scrollbars
  • Cursor moves to left position in some GCE dialog
  • Problems with 'Do not display the next time' switch in module selection of validation and generation dialog
  • Bad performance on creating GCE perspective for modules with a large count of entities
  • Display issues with different Windows design schemas
  • Os TimingAnalyzer does not start in some cases
  • 'Jump to ...' to does not work properly
  • MyController setting will not be saved in .profile
  • Wrong 'Cannot map data' warnings are printed
  • Implementation-Info will not be shown correctly for split BSWMD files
  • VisualStudio locks generated file and raises exception on rewriting output
  • Loaded InstanceRefs will be deleted on saving
  • Import Append/Replace does not work properly in some cases
  • SymbolicNameReferences have no value list if destination definition file is missing
  • Exception is raised in spin columns
    MICROSAR Generator
  • 'Do not modify ...' comment in generated user-changeable output files

(top)

DaVinci Configurator Pro 4.0

Tool features

  • The combination of DaVinci Configurator Pro lets you configure all of the BSW modules.
  • Conformance to AUTOSAR specifications 2.1.0, 2.1.1, 2.1.2, 2.1.4, 3.0.0, 3.0.1, 3.0.2
  • Simplified representation of complex configuration interrelationships
  • Preselection of valid input values
  • Mature, rule-based validation process
  • Validity and consistency check of individual values over the entire project

(top)