DaVinci Configurator Pro Release NotesCopyright © 2008-2014 by Vector Informatik GmbH
Table of contents
New features
- 'Compare To...' is available for DaVinci Configurator Base if SIP contains valid RTEConfigurator license
- Reworked 'Compare To...' algorithm and display
MICROSAR Generator- New commandline options '-CondGen' and '-noCondGen': Enable/disable conditional generation of files
Fixed issues
- Trying to remove Containers results in access violation
- Validation may lead to crash if JumpTo target is not available
- Evaluating 'active' state of GENy-modules may not work correctly for splitted DPA projects (rework of algorithm)
- 'Compare To...' of single module configuration does not work (for splitted DPA projects)
- Saving large project fails due to 'out-of-memory' exception
MICROSAR Generator- Creating converted ECUC ecuc file for several external Generators now correctly gathers all required module configurations
- Running multiple instances at once fails due to 'incorrect' file locks
- Converting ecuc file to different AUTOSAR revision removes MODULE-DESCRIPTION-REF
(top)
New features
- 'Compare To...' now may also be triggered from command line by using new '-mergeWith <other-project>' option
MICROSAR Generator- Prevent generation of empty 'Licensee' information
Fixed issues
- Preconfigured containers of EepAt25128 will not be shown and generated correctly
- ECUC-lock is not retrieved after generation process
- Xslt transformation creates 'invalid' UTF-8 document
- Module definition with empty LONG-NAME node results in crash
MICROSAR Generator- Incomplete validation if commandline option '-m' contains module definition reference
(top)
New features
- Extend 'Compare To...' with side-by-side comparison of module configuration
- Extend 'Compare To...' with partial or complete merge of module configuration
- Enable drag-and-drop to compare project or module configuration via file dropping
- Support Configurator 5 related packages
- Support AUTOSAR 3.2.2 specification
- Support AUTOSAR r4.0 specification
MICROSAR Generator- New commandline option '-syncmem': Calculate of all memory block attributes and save configuration
- New commandline option '-remPreCfg': Remove PreConfiguration for specified module(s)
- New commandline option '-version': Provide parameter to get version string of running microsargen
- New commandline option '-noxsd': Skip project file from AUTOSAR schema validation
- Commandline option '-m' supports specification of module definition reference e.g. '-m /MICROSAR/Ea' instead of '-m Ea'
- Calculate /MICROSAR/Ea and /MICROSAR/EaBasic/Ea block attributes before validation within AUTOSAR 4 environment
Fixed issues
- 'Compare To...' lists differences for unchanged module configuration
- 'Compare To...' does not handle dpa files
- Floating license will sometimes not be recognized
- Removing preconfigured configuration do not remove preconfigured container itself
- Loading project sometimes creates duplicates of nested container objects
- JumpTo functionality of message window may lead to crash
- Import of references fails if AR-PACKAGE uses same short-name as module configuration
- 'Import/Append' do not derive shortnames for all appended container objects
- Creating module instances in architecture view may result in errors and error messages
- Closing application prints wrong message of 'Running Recorder within dongle installation
:- Keyman Dongle stalls application with different USB devices
- Exception on loading project with WdgIf config within AUTOSAR 4 environment
- Wrong display of reference value in WdgRef if referring to other Wdg instance than Wdg
- Loading project prints wrong warning 2102 'Cannot load data of [..] no definition found in definition file(s) in some cases
- UPPER-MULTIPLICITY-INFINITE fails for '0'/'1' values within AUTOSAR4 environment
- Print warning if 'Unlock configuration' is removed for read-only module in architecture view
- Refresh Log folder in project explorer to display 'Import-LogFile' at the end of import process
- The load of a definition file set of modules with same name but in different sub-Packages is not executed correctly
- A preconfigured value is changed by a recommended value in some rare cases
- Find parameter with option 'Name' does not show the value of the parameter in the result list
- Value of enum literal of SpiPrearrangedBus is changed just by entering control
- Ea validation prints wrongly error message with Erase Unit size (V005)
- Parameter help window does not show complete description text on japanese WinXP
MICROSAR Generator- EcuM generator prints wrong error message for missing preconfigured configuration of CanTrcv_Generic1CanDio
- Extend -p option with printing AUTOSAR namespace information in project header
- New commandline arguments for -save, -syncmem and -remPrfg missing in -? option
- Dependencies are sometimes not recognized for AUTOSAR4 definition files
(top)
Copyright
© Vector Informatik GmbH
Certified Quality Management System
The Quality/Process Management of Vector Informatik GmbH is being certified
according to DIN EN ISO 9001:2000-12 (formerly DIN EN ISO 9001:1994-08)
throughout since 1998-08-19.
Vector Informatik GmbH - Addresses
Vector Informatik GmbH
Ingersheimer Str. 24
D-70499 Stuttgart, Germany
Phone: +49 711 80670-0
Fax: +49 711 80670-111
info@de.vector.com
https://vector.com
Subsidiaries
Vector Austria GmbH
Millennium Tower, Etage 41
Handelskai 94-96
1200 Vienna
Austria
Phone: +43 1 90160-0
Fax: +43 1 90160-35
info@at.vector.com
http://www.vector-austria.com
Vector Automotive Technology (Shanghai) Co., Ltd.
Sunyoung Center
Room 1601-1603, No.398 Jiang Su Road
Changning District
Shanghai 200050
China
Phone: +86 21 6432 5353-0
Fax: +86 21 6432 5308
info@cn.vector.com
http://vector-china.com
Vector France S.A.S.
168, Boulevard Camélinat
92240 Malakoff
France
Phone: +33 1 423140-00
Fax: +33 1 423140-09
information@fr.vector.com
http://vector-france.com
Vector GB Ltd.
Rhodium
Central Boulevard
Blythe Valley Park
Solihull, Birmingham
West Midlands B90 8AS
United Kingdom
Phone: +44 121 50681-50
Fax: +44 121 50681-69
info@uk.vector.com
http://www.vector-gb.co.uk
Vector Informatik India Pvt. Ltd.
4/1/1/1, Sutar Icon, Sus Road
Pashan, Pune - 411 021
India
Phone: +91 20 2587-2023
Fax: +91 20 2587-2025
info@in.vector.com
http://www.vector-india.com
Vector Japan Co., Ltd.
Tennozu Yusen Bldg. 16F
2-2-20 Higashi-shinagawa, Shinagawa-ku
Tokyo 140-0002
Japan
Phone: +81 3 5769-7800
Fax: +81 3 5769-6975
info@jp.vector.com
http://www.vector-japan.co.jp
Vector Korea IT Inc.
Gomoas Bldg. 5F
12 Hannam-daero 11-gil Yongsan-gu
Seoul 140-889
Republic of Korea
Phone: +82 2 8070-600
Fax: +82 2 8070-601
info@kr.vector.com
http://www.vector-korea.com
VecScan AB
Theres Svenssons Gata 9
417 55 Gothenburg
Sweden
Phone: +46 31 76476-00
Fax: +46 31 76476-19
info@se.vector.com
http://www.vecscan.com
Vector CANtech, Inc.
39500 Orchard Hill Place
Suite 550
Novi, Michigan 48375
USA
Phone: +1 248 449-9290
Fax: +1 248 449-9704
sales@us.vector.com
http://www.vector-cantech.com
(top)
Copyright © 2008-2014 by Vector Informatik GmbH
(main overview)
Table of contents
New features
- Print 'display name' of configuration entity created from long-name definition in GCE, parameter help window...
- Allow user to switch between LongNames and ShortName in GCE
- Extend auto-set mechanism for enumeration parameters with one literal
- Extend Gce with comment column to ease usage of comments
- Add 'Create desktop shortcut' of current project to main menu
- Provide new menu items of context menu in project explorer for all actions that are project-relevant
- Show definition references in module list of project options
- Support new license dongle (Vector Keyman)
- Enable dll-lock-mapping for GENy-modules Eth, EthIf, EthSm, EthTrcv
- Support AUTOSAR 3.2.2 specification
MICROSAR Generator- Provide $(DpaProjectFile) variable in external generator settings
- Generation of %.Object% does no longer work correctly for each case
- Generation of %.AbsoluteTargetDir% and %.TargetDir% does no longer work
- Generationg with -m IoHwAbstraction fails with 'no definition found...' error message
- Misleading message of 'No license found for module 'Dio'' on starting generator with -m Dio option corrected
- Generating EcuM prints error message regarding to missing Mcu param
Fixed issues
- First column is set read-only sometimes
- Exception on parsing SIP with corrupted file structure
- Reference to inactive module may lead to crash when loading project
- Missing online help for license manager
- Issue with update of modified data on saving project
- Wrong position of 'delete block' button in NvM blockdescription table
- Emphasize is not shown with related editor frame in time
- Recommended configuration for ForeignReference is not considered correctly
- Reloading reference value fails sometimes
- Splitted ECUC file - Board will be removed from EcuConfiguration/ModuleRefs list
- JumpTo does not focus GCE if selected parameter is not found in comfort view
- Empty arxml file will be saved for SIP with non-AUTOSAR-modules
- Compare To... displays current project filename instead selected one
- BSW-Implementation dialog does not show version information for AUTOSAR 4.0
- Recommended configuration and Preconfiguration are not applied correctly for AUTOSAR 4.0
- Use of JumpTo-functionality may result in crash
(top)
New features
- Improved performance when showing tables with complex configuration tasks
- Improved handling of 'Find Configuration Entity' dialog
- SSWC files will be removed if 'Use RTE' switch is not set in according BSW module
- New menu 'Project/Compare To...' with report of changes between current ECUC and stored or selected one
- New 'intelligent' Import/Update option
- Logfile for Import/Update and Import/Append
- Distribute new version of Vector License Manager
- GCE view can toggle between displaying ShortNames or LongNames of parameters and references
MICROSAR Generator- Support AUTOSAR 4.0 (without VARIATION-POINT handling)
Fixed issues
- LongName of parameter definition overrides user-defined editor labels
- Table shows wrong values on related panels in OS task configuration, table content on page will not be properly updated
- First column of tables is initially locked
- Module configuration editor is not available for just-activated modules
- Scrollbars are not shown sometimes
- JumpTo-functionality shows Hint-Arrow before jumping to correct page
- Other Vector Tools get lock for ECUC file although value was modified
- Hex/Dec button does not change format
- Labels are sometimes missing (Win7)
- Handling of AUTOSAR Stub-Configuration does not work correctly for splitted DPA projects
- Class PreConfiguration locks wrong cells in table
- Import/Append only works once (without reloading project)
- Automatic reference update does not work in some cases
- BSW-Implementation dialog does not show 'Requires' correctly for 'Multi-Package' module definitions
- Dirty-flag will be set if comfort view of module is opened
- 'Find Configuration Entity' dialog will crash if values are deleted while it is opened
- Sorted table sometimes changes order of rows if table is not sorted by unique values
- Default value will not be set for Multiline-String-Parameter
- ReadOnly mode for GENy components locks 3rd party components
- Main menu '?/Samples' shows too many entries
- Labels overwrite other controls (preventing e.g. access of selection controls)
- Reference to inactive Module may lead to crash when loading project
MICROSAR Generator- Generator-call for complex device drivers will not be loaded correctly from Identifier.xml
- GenRule Type IncludeList does supports multiple values for expression %Identifier.Object/Parameter%
(top)
New features
- Support AUTOSAR 3.2.1 specification
- ReadOnly mode for GENy components (with each project handling current state of 'lock' itself)
- Recorder for ECUC changes
- Create a stripped down package with information for support requests
- Support sorting according to SymbolicNameValue in GCE view
- Change order of containers in GCE view with MoveUp and MoveDown option
- Support extended filter functionality in all combobox columns of tables
- 1st Level Validation should be executed completely and independent of existance of Validation.xml
- Improved performance for loading and saving large ECUC files
- Improved performance for applying PreConfiguration and Recommended Configuration
- Improved performance for opening/switching view with extensive Actions
- New option '$(Package)' for external tools
- Allow saving a 'purged' configuration of modules (= without PreConfiguration) into ECUC file
- Provide 'Find Entitiy ...' as toolbar icon of project explorer for quick access
- Provide quick access to module preferences in context menu of architecture
- Harmonisation of ECU contents (for float values and empty elements) with GENy and DaVinci Developer
- Results of 'Detect Unresolved References' now support Jump-To-Error feature
MICROSAR Generator- Omit printing the same (Validation) message too often
- Use only required modules for conversion of ECUC file to different AUTOSAR revision, not complete ECUC file
Fixed issues
- F6 key support for opening special dialogs does not always work
- Architecture 'Compare To ...' dialog mixes 'shown' and 'to-be-saved' values of parameters
- Package license does not work if UNC-notation is used for path definition
- Unexpected windows sound on field editing
- XCopy Installation raises wrong 'No controller information available in ...' error message
- Correct license activation is not recognized in rare cases
- Starting with dpa-file for invalid package license results in access violation
- MODULE-DESCRIPTION-REF is not written into ECUC file
- F5 key creates new values for some parameters and references
- Validation with external tools does not work for splitted ECUC
- Merged ECUC file for external tools uses wrong AUTOSAR revision
- Scrollbars are not shown if not all input fields fit on view of module
- Default value is shown in View but will not be saved
- Reference targets will not be found in Group which uses SUB-PACKAGES in module definition
- Labels are missing sometimes when using Windows 7
- 'Not empty' check will not be executed correctly for Identifiers of new Container
- Some Containers are not selectable in GCE view
- Access violation may occur when deleting UserBlocks in NvM
- ComSignals can be added while in ReadOnly mode
- Context menu does not show correct types of Sub-Containers in GCE view
- After Validation parameter help window does no longer work correctly
- Splitter above table is not shown correctly
- Architecture is empty when closing and reopening it
- PrettyPrint of ECUC file invalidates empty VALUE-REF nodes
- Minimum relation of Containers is not considered correctly when creating new project
- DaVinci Project Assistant does not get ECUC-lock when started from 'File/Project Assistant/Project Settings...'
- PreConfiguration and Recommended Configuration for reference values is not applied correctly
- Recommended Configuration and Recommended Class Configuration are not applied correctly for ConfigurationSets
- Creating 'Dem Events' in 3rd party Dem fails
- Cascaded Preconfigured Class Configuration and Recommended Class Configuration are not applied correctly
- Automatic update of Reference values does not work correctly in some cases
- Values of Instance-References are not loaded
- 'Del' key is working in locked GCE view
MICROSAR Generator- Generation of WdgIf fails for values of WdgExt
- Commmandline Generation does not accept different camelcase spelling of module
- XSL-Generation does not work for splitted ECUC
(top)
New features
- Support of multi selection with bulk change in GCE and tables
- AutoComplete and extended search functionality for dropdown lists
- Enhanced usability in dialog for editing references
- New validation and generation dialog
- New 'Compare To...' feature in architecture view with possibility to create a simple report for all changed entity values
- Introducing new naming 'Code Templates' for user changeable files
- New project on welcome screen now starts DaVinci Project Assistant
- The sort order of items in GCE view can be configured
- The parameter information dialog shows the LONG-NAME of a selected entity
- Support of simple html tags (<b>, <i>, <u>) in control tooltip
- Integer values can be displayed in binary format (optional as replacement to dec/hex display)
- Support of unsigned 64-Bit integer values
- Create a report which contains all changed entity values
- Parse package license folder automatically (without usage of System.xml)
- Improved handling of large Windows fonts (120 dpi)
- Recalculate derived parameters after opening ECUC file
MICROSAR Generator- Switch for conditioned generation becomes project-specific
Fixed issues
- Show tooltip and parameter information for locked parameters in comfort perspectives
- Import of Foreign-References does not work correctly (DEST-attribute is not imported)
- Cryptic error messages if XML schemes are locked by a different tool
- ImplementationVariant of ECUC file is not considered
- ActionLists should be executed only within 'own' instance
- Invalid data of control is not 'ignored' correctly
- GCE view does not show current instance
- Performance problem on opening Tools/Preferences dialog with a large set of modules
- Recommended value information is not displayed correct
- Identifier function '.Object' does not work if a different module is referenced
- Parameter information is not shown properly if control affects other controls
- Imported module configuration does not use AR-PACKAGE of ECUC file
- Order of module configurations in ECUC file is changed on saving
- Import does not work for inactive module
- 3rd party modules are not shown in Tools/Preferences dialog if home folder is invalid
- Saving large ECUC file fails
- Modules without comfort view are not shown in project explorer
- Splitted ECUC will not be saved correctly
- PrettyPrinting of ECUC file differs from PrettyPrinting done by GENy
- Adding comments results in 'corrupted' ECUC file
- Automatically created ValueList does not work correctly if literals in module definition use LONG-NAME
- Change detection does not work correctly for splitted ECUC
- PreConfiguration of Containers without childs-Values does not work
- Parameters set for Pre- or PostGeneration cannot be saved
- Modules 'renamed' in Identifier.xml (e.g. IoHwAb) will not work correctly for DPA project
- References to 'not-standard-AUTOSAR' modules will not work correctly for PreConfiguration
- ValueLists on related Panels of table will not be updated
- The option 'Select Values...' in comfort view does not work
- Copying Containers does not copy sub-Containers correctly (if their MinRelation is larger than 1)
- When creating Containers the MinRelation of sub-Containers sometimes is not considered correctly
- Certain Containers are not shown in GCE view
- Modules not available in DaVinciCFG will be deleted from ECUC file
- Splitted ECUC using different AUTOSAR revisions results in errors
- Importing module configurations into splitted ECUC does not work
- Saving when closing splitted ECUC may invalidate main splitter
MICROSAR Generator- Parameter '$(GenDataFolder)' will not be passed correctly to external generator
(top)
New features
- Windows 7 support
- Multi-User support with splitted ECUC
- Generate output only if related configuration is modified (switchable in Tools/Preferences)
- Consider MinRelation of Sub-Containers, Parameters etc when creating new Container
- PreConfiguration will be applied to multiple instances of a module
- Internal name of module supports underscores (Note: If internal module name contains underscores, Identifier-notation may not be used for this module)
- View Tab names of instanceable modules are simplified
MICROSAR Generator- Start validation with xsd validation
Fixed issues
- Checkboxes without value are not shown correctly in tables
- Scrollbars are not shown correctly for large Panels of TableFrame
- BSWMD files containing multiple xml-namespaces result in access violation
- Loading project with TargetFolders set for DaVinci Project Assistant can result in stack overflow
- PreConfiguration is not entered at correct position when loading ECUC files
- Screen starts to flicker during extensive actions
- ValueLists show Containers of inactive modules
- ShortName of module configuration is fixed if PreConfiguration is used
- 'Save' is disabled although module configuration was changed during loading
- Sorted table shows wrong value on related Panels
- Handling of instancable modules
- 'Recent Projects' list is not shown at correct position on japanese Windows XP
- References were not updated correctly if target module was renamed
- 'Revert To Initial Values' in Architecture can sometimes result in access violation
- Access to not existing optional parameter results in index out of bounds exception
- 'Extended' xsd-check (= ShortNames may have up to 128 chars) reports errors for long reference values
- 'Undefined' checkboxes are not shown correctly for related Panels of TreeFrames and TableFrames
- Controls are not enabled correctly on Os-view
- MinRelation of Containers, Parameters etc is considered before loading a project instead of after loading it
- Switching pages in comfort view can result in access violation
- When switching pages in GCE view sometimes certain values are not shown correctly
- Selected Choice Containers are not loaded correctly if lower multiplicity is set wrong in module definition
- In some cases multiple configuration container is not shown correctly in TreeFrame
- Update module configuration when saving ECUC after 'Revert To Initial Values' was used
- Saving ECUC fails due to unexplained reason
- Wrong context is used in ActionLists and for enabling Controls
(top)
New features
- Support of Fold Containers in GCE to enhance clarity of GCE tree
- Support of Cut, Copy and Paste of containers in GCE
- Create validition log file in XML format where all executed validation rules are signed per ID with status OK or NOK
- Support use of variable names in folder specifications
- Extend parameter context menu with new item to undefine a parameter
- Enhance usability of assigning package license to projects
- Provide new menu item in Architecture view to revert module configuration to default with optional Recommended Configuration
- Enhance performance on loading projects and module editors
- Extend find parameter dialog with possibility to search for parameter comments
- Extend table context menu to insert or delete selected row
- Extend project menu with new item to test multiple configuration container names for uniqueness
- Read and write ECUC files with more than one AR-PACKAGE
- Support message numbers in all user messages
- Close nested messages automatically if they only contain uncritical severity messages
- Harmonize XSD validation with possibility to ignore ShortName length violation
- Extend message context menu with item to open files with unknown file association
- Support AUTOSAR 3.0 Rev6 and 3.1 Rev4
- Support bit-operations in formula descriptions
- Status line reworked for better understandability
- Consider MinRelation of Containers, Parameters etc when creating new project
MICROSAR Generator- Generation.log file format changed to XML
- Print user notification in module selection dialog for dependencies of modules that become deactivated
- Support starting generator with dpa-file
- Provide option to switch off the creating of *.bak files during generation
- Save user code from Removed Code Area on restart of generation process
Fixed issues
- The parameter help window is empty after insertion of a new row in a table
- The range of integer or float param is not displayed in the parameter help window
- Wrong short cut description in context menu for parmeter help found (should be Shift+F1)
- The project explorer becomes not synchronized in some case
- Set value to default fails with wrong pasted text in some case
- Jump-To-Error fails in some cases
- ECUC change detection shall not be executed if application is not focused
- Error messages of 3rd party generators are not well-formed if project path contains blank char
- Button for Hex/Dec format wrongly stays disabled in some case
- Access violation when changing editors in some case
- ECUC pretty print becomes not well-formed in some case
- Path specifications containing '#' cause errors on creating editors
- Tooltips are sometimes not readable
- An existing Recommended Configuration is not considered when a module is added to the project
- ShortName naming algorithm skips free numbers
- DaVinci Project Assistant does not save ECUC before "update ecuc project..." is executed
- The error Messages raised from DaVinci Project Assistant are not displayed completely
- Loading a file can 're-enter' optional Containers
- Saving fails if 'MSXML 6.0 SP2' is used
- Performance issue when opening large comfort views
MICROSAR Generator- Parameters $(EcucFile) and $(EcucFolder) are passed incorrectly to external Validator/Generator if 'Supply AUTOSAR Revision' option is used
- Relative project paths specified by DaVinci Project Assistant are not generated to the correct folder
(top)
New features
- Display names of module perspectives in project explorer
- Usage of license.bin becomes obsolete
- Support PreConfigured and Recommended Class Configuration
- The display format of Integer parameters can be changed by user to decimal, hex or binary format
- Support GENy dll for generation of SWC
- Full integration of new Project Assistent in user interface
- Create new ECUC project based on system extract
- Update current ECUC project with new modified system extract
- Edit common project settings
- Establish context menu for each parameter to support actions to
- add or modify a comment string
- reset the parameter value to the specified default value
- reset the parameter value to the specified recommended value
- open a popupwindow with all information raised from definition
- Support AUTOSAR release 3.1 (together with accrued patch releases 3.0.3, 3.0.4, 3.1.1, 3.1.2)
- Support usage of identifier.xml to cover extensions of AUTOSAR specification
- Support derived parameter types with Vector formula description
- Support concurrent ECUC access between MICROSAR tools
MICROSAR Generator- Restrict loading to necessary dependent BSW modules to enhance performance
Fixed issues
- Missing external generator will not be reported
- Renaming SymbolicNameRef parameter results in invalid value
- If an existing but invalid package license entry is found in any project, the project will not be loaded
- Save module configuration to ECUC only if really changed
- Deactivating modules does not work in some cases
- Parsing definition files fails sometimes if additional files found e.g. /bswmd/project.pj
- ECUC change detection hangup in a special environment
- The mousepointer will not be set back to default on leaving project explorer
- Relative paths are resolved not relative to project folder
- Import Append fails sometimes
- Context menu item 'Jump To ...' becomes not enabled
MICROSAR Generator- Calling external generator removes foreign created temp files
(top)
New features
- Provide finding AUTOSAR objects in current configuration
- Provide new menu item to launch GENy with current project configuration
- New message register 'Result List' for a message summary grouped by message type
- Provide new context menu item in architecture for validating module definition file(s)
- Provide new context menu item in architecture for importing module configuration with replace or append option
- Provide new context menu item in architecture for opening user added documents
- Display user notification if current ECUC file is changed from other application (Change Detection)
- Display dependencies between modules in implementation help window
- Display AUTOSAR origin, derivation and destination reference in parameter help window
- Provide new context menu to close selected tab or all tabs except selected one
- Print warning message on loading a module configuration with a different definition reference except standard definition reference
- Assign vendor-specific definition on loading a module with a standard AUTOSAR definition
- Validation of a module can be performed completely and without breaking on first error
- Provide new menu item to verify UUID values of current project
- Improvement on calling GENy generator
- Provide special GCE view for Com- and IPduSignals
- Provide new .profile setting to launch associated application after creating a report file
MICROSAR Generator- Support -tswc command line option to set directory name for generated SWC description files
- Support -tuser command line option to set the target directory name for generated user-changeable files
- Support -h command line option for help
DaVinci Difference Viewer- Display of semantic differences between AUTOSAR XML files
- Supports System Description files, SWC Description files and ECU-C files
- Integrated into Windows Explorer context menu for files with extension .arxml
Fixed issues
- Extend handling of undefined boolean parameter values
- 3rd party generator cannot be started if its working directory contains blanks in path specification
- 3rd party modules are not shown sometimes in project explorer
- Wrong architecture mapping for FEE module
- Create tooltip and Ctrl-F1 to access parameter information for locked parameters in GCE mode
- Redesign of register 'Changes' in message window
- Different display of messages, no multiple-selection of messages, missing scrollbars
- Cursor moves to left position in some GCE dialog
- Problems with 'Do not display the next time' switch in module selection of validation and generation dialog
- Bad performance on creating GCE perspective for modules with a large count of entities
- Display issues with different Windows design schemas
- Os TimingAnalyzer does not start in some cases
- 'Jump to ...' to does not work properly
- MyController setting will not be saved in .profile
- Wrong 'Cannot map data' warnings are printed
- Implementation-Info will not be shown correctly for split BSWMD files
- VisualStudio locks generated file and raises exception on rewriting output
- Loaded InstanceRefs will be deleted on saving
- Import Append/Replace does not work properly in some cases
- SymbolicNameReferences have no value list if destination definition file is missing
- Exception is raised in spin columns
MICROSAR Generator- 'Do not modify ...' comment in generated user-changeable output files
(top)
Tool features
- The combination of DaVinci Configurator Pro lets you configure all of the BSW modules.
- Conformance to AUTOSAR specifications 2.1.0, 2.1.1, 2.1.2, 2.1.4, 3.0.0, 3.0.1, 3.0.2
- Simplified representation of complex configuration interrelationships
- Preselection of valid input values
- Mature, rule-based validation process
- Validity and consistency check of individual values over the entire project
(top)