IDBaselined v2.2 and ReleasedIs Requirement?.ASIL.ReqCatReview DateReview ActionReview Action Status
ES200A_1PurposeFALSENA



ES200A_9The Current Measurement function is responsible for measuring the motor phase currents used as feedback by the Motor Control FDD. Three motor phase currents are measured using three low-side shunt resistors and three integrated differential amplifier circuitry for each motor. Then measured currents are transformed into direct (D) and quadrature (Q) axes currents using the combined Clarke/Park transformation.
FALSENA



ES200A_2Interface RequirementsFALSENA



ES200A_11DefinitionsFALSENA



ES200A_12InputsFALSENA



ES200A_48MotCurrInpPhyA: Physical motor current to be measured by shunt A and sense amplifier A.
FALSENA



ES200A_188MotCurrInpPhyB: Physical motor current to be measured by shunt B and sense amplifier B.
FALSENA



ES200A_191MotCurrInpPhyC: Physical motor current to be measured by shunt C and sense amplifier C.
FALSENA



ES200A_195MotCurrInpPhyD: Physical motor current to be measured by shunt D and sense amplifier D.
FALSENA



ES200A_194MotCurrInpPhyE: Physical motor current to be measured by shunt E and sense amplifier E.
FALSENA



ES200A_193MotCurrInpPhyF: Physical motor current to be measured by shunt F and sense amplifier F.
FALSENA



ES200A_51MotCtrlMotCurrAdcVlyA: Phase A current measurement signal in volts.
FALSENA



ES200A_273MotCurrAdcVlyA: Phase A current measurement signal in volts.
FALSENA



ES200A_52MotCtrlMotCurrAdcVlyB: Phase B current measurement signal in volts.
FALSENA



ES200A_274MotCurrAdcVlyB: Phase B current measurement signal in volts.
FALSENA



ES200A_199MotCtrlMotCurrAdcVlyC: Phase C current measurement signal in volts.
FALSENA



ES200A_275MotCurrAdcVlyC: Phase C current measurement signal in volts.
FALSENA



ES200A_198MotCtrlMotCurrAdcVlyD: Phase D current measurement signal in volts.
FALSENA



ES200A_276MotCurrAdcVlyD: Phase D current measurement signal in volts.
FALSENA



ES200A_197MotCtrlMotCurrAdcVlyE: Phase E current measurement signal in volts.
FALSENA



ES200A_277MotCurrAdcVlyE: Phase E current measurement signal in volts.
FALSENA



ES200A_196MotCtrlMotCurrAdcVlyF: Phase F current measurement signal in volts.
FALSENA



ES200A_278MotCurrAdcVlyF: Phase F current measurement signal in volts.
FALSENA



ES200A_67MotCurrSnsrOffs1: Gate Drive 1 sense amplifiers offset output
FALSENA



ES200A_66MotCurrSnsrOffs2: Gate Drive 2 sense amplifiers offset output
FALSENA



ES200A_65MotCtrlPhaOnTiA: Number of On-Time Counts for Phase A.
FALSENA



ES200A_83MotCtrlPhaOnTiB: Number of On-Time Counts for Phase B.
FALSENA



ES200A_84MotCtrlPhaOnTiC: Number of On-Time Counts for Phase C.
FALSENA



ES200A_201MotCtrlPwmPerd: Newly computed PWM period is used to determine the PWM duty cycle.
FALSENA



ES200A_61MotCtrlBrdgVltg: Voltage provided to the application to indicate the battery voltage. The Bridge Voltage can be switched by design between Battery Voltage, Switched Battery Voltage1 and Switched Battery Voltage 2.
FALSENA



ES200A_287BrdgVltg: Voltage provided to the application to indicate the battery voltage. The Bridge Voltage can be switched by design between Battery Voltage, Switched Battery Voltage1 and Switched Battery Voltage 2.
FALSENA



ES200A_92MotCtrlMotAgElec: Corrected Motor Position after back emf correction.
FALSENA



ES200A_91MotCtrlMotVelMrf: Motor Velocity into Motor Reference Frame
FALSENA



ES200A_286MotVelMrf: Motor Velocity into Motor Reference Frame
FALSENA



ES200A_89VehSpd: Vehicle speed used to determine if the manufacturing EOL calibrations can be done.
FALSENA



ES200A_88VehSpdVld: Used as a part of manufacturing EOL service request to determine if the vehicle speed is valid.
FALSENA



ES200A_87MotCtrlCtrlrTFild: Controller temperature filtered, used to adjust the EOL offset due to temperature variation.
FALSENA



ES200A_86MotCtrlSysSt: Newly computed system state. Used to determine which protocol check to be performed.
FALSENA



ES200A_290SysSt: Newly computed system state. Used to determine which protocol check to be performed.
FALSENA



ES200A_200MotCtrlMotElecMeclPolarity: Motor electro mechanical polarity to determine the orientation of the three phases.
FALSENA



ES200A_205MotCtrlStrtUpSt: Power up sequence enumerations to indicate when to start the warm-init protocol check.
FALSENA



ES200A_208MotCtrlDiagcStsIvtr1Inactv: Inverter 1 inactive status from the Diagnostic Manager.
FALSENA



ES200A_288DiagcStsIvtr1Inactv: Inverter 1 inactive status from the Diagnostic Manager.
FALSENA



ES200A_207MotCtrlDiagcStsIvtr2Inactv : Inverter 2 inactive status from the Diagnostic Manager.
FALSENA



ES200A_289DiagcStsIvtr2Inactv : Inverter 2 inactive status from the Diagnostic Manager.
FALSENA



ES200A_281MotCtrlCurrMeasWrmIninTestCmpl: This flag will indiate the Power-up sequence function that Current Measurement warm init protocol test is complete.
FALSENA



ES200A_283Ntc5DErrCnt: NT0x5D error counter which is an input for the 2ms periodic.
FALSENA



ES200A_282Ntc6DErrCnt: NTC0x6D error counter which is an input for the 2ms periodic.
FALSENA



ES200A_304MotCtrlMotCurrAdcVlyAAdcFaild: A signal that indicates that the Adc converting the MotCtrlMotCurrAdcVlyA signal has failed.
FALSENA



ES200A_303MotCtrlMotCurrAdcVlyBAdcFaild: A signal that indicates that the Adc converting the MotCtrlMotCurrAdcVlyB signal has failed.
FALSENA



ES200A_302MotCtrlMotCurrAdcVlyCAdcFaild: A signal that indicates that the Adc converting the MotCtrlMotCurrAdcVlyC signal has failed.
FALSENA



ES200A_307MotCtrlMotCurrAdcVlyDAdcFaild: A signal that indicates that the Adc converting the MotCtrlMotCurrAdcVlyD signal has failed.
FALSENA



ES200A_306MotCtrlMotCurrAdcVlyEAdcFaild: A signal that indicates that the Adc converting the MotCtrlMotCurrAdcVlyE signal has failed.
FALSENA



ES200A_305MotCtrlMotCurrAdcVlyFAdcFaild: A signal that indicates that the Adc converting the MotCtrlMotCurrAdcVlyF signal has failed.
FALSENA



ES200A_13OutputsFALSENA



ES200A_104MotCtrlMotCurrCorrdA: Phase A current in amps converterd from MotCurrAdcVllyA
FALSENA



ES200A_103MotCtrlMotCurrCorrdB: Phase B current in amps converterd from MotCurrAdcVllyB
FALSENA



ES200A_102MotCtrlMotCurrCorrdC: Phase C current in amps converterd from MotCurrAdcVllyC
FALSENA



ES200A_101MotCtrlMotCurrCorrdD: Phase D current in amps converterd from MotCurrAdcVllyD
FALSENA



ES200A_100MotCtrlMotCurrCorrdE: Phase E current in amps converterd from MotCurrAdcVllyE
FALSENA



ES200A_99MotCtrlMotCurrCorrdF: Phase F current in amps converterd from MotCurrAdcVllyF
FALSENA



ES200A_97MotCurrQlfr1: Qualifier to indicate the status of the current sense amplifiers of Gate Drive 1.
FALSENA



ES200A_109MotCurrQlfr2: Qualifier to indicate the status of the current sense amplifiers of Gate Drive 2.
FALSENA



ES200A_95MotCtrlMotCurrRollgCntr1: Rolling Counter will be incremented each time a new set of valid phase current measurement of Inverter 1 is received from the ADC.
FALSENA



ES200A_110MotCtrlMotCurrRollgCntr2: Rolling Conuter will be incremented each time a new set of valid phase current measurement of Inverter 2 is received from the ADC.
FALSENA



ES200A_203MotCurrEolCalSt: Motor Current EOL offset and gain calibration Enumeration states.
FALSENA



ES200A_202MotCtrlCurrMeasMotAgCorrd: Corrected motor position to convert from phase to phase signal to phase to neutral signal after compensating the motor position sensor delay.
FALSENA



ES200A_204CurrMeasWrmIninTestCmpl: This flag will indiate the Power-up sequence function that Current Measurement warm init protocol test is complete.
FALSENA



ES200A_284MotCtrlNtc5DErrCnt: NT0x5D error counter which is an output from the motor control loop 62.5us periodic.
FALSENA



ES200A_285MotCtrlNtc6DErrCnt: NT0x6D error counter which is an output from the motor control loop 62.5us periodic.
FALSENA



ES200A_41Internally Defined TermsFALSENA



ES200A_206None.
FALSENA



ES200A_3RequirementsFALSENA



ES200A_4Primary Functional RequirementsFALSENA



ES200A_15The Current Measurement function shall provide three phase currents for each inverter within a TBD range and TBD resolution.

Note: For T1XX Range = ±145Α, Resolution = 0.08138 Amp/Cnt.
TRUEDDirect7/31/2015
Closed
ES200A_269The Current Measurement function shall use the value for the MotCtrlMotCurrAdcVlyA if MotCtrlMotCurrAdcVlyAAdcFaild is FALSE.
TRUEDDirect3/10/2016
Closed
ES200A_312The Current Measurement function shall use the value for the MotCtrlMotCurrAdcVlyB if MotCtrlMotCurrAdcVlyBAdcFaild is FALSE.
TRUEDDirect3/10/2016
Closed
ES200A_311The Current Measurement function shall use the value for the MotCtrlMotCurrAdcVlyC if MotCtrlMotCurrAdcVlyCAdcFaild is FALSE.
TRUEDDirect3/10/2016
Closed
ES200A_310The Current Measurement function shall use the value for the MotCtrlMotCurrAdcVlyD if MotCtrlMotCurrAdcVlyDAdcFaild is FALSE.
TRUEDDirect3/10/2016
Closed
ES200A_309The Current Measurement function shall use the value for the MotCtrlMotCurrAdcVlyE if MotCtrlMotCurrAdcVlyEAdcFaild is FALSE.
TRUEDDirect3/10/2016
Closed
ES200A_308The Current Measurement function shall use the value for the MotCtrlMotCurrAdcVlyF if MotCtrlMotCurrAdcVlyFAdcFaild is FALSE.
TRUEDDirect3/10/2016
Closed
ES200A_268The Current Measurement function shall provide qualified status of the fault.
TRUEDDirect7/31/2015
Closed
ES200A_271The Current Measurement function shall provide instantaneous status of the protocol fault.
TRUEDDirect7/31/2015
Closed
ES200A_267The Current Measurement function shall provide fault injection mechanism to manipulate final motor phase current measurements result.
TRUEDDirect7/31/2015
Closed
ES200A_270The Current Measurement function shall provide fault injection mechanism to inject protocol failure.TRUEDDirect7/31/2015
Closed
ES200A_272The Current Measurement function shall need a mechanism for the SPI configured Gain TBD value and Offset TBD value to be verified.

Note: For T1xx, Gain = 30V/V, Offset = 2.5V.
TRUEDDerived7/31/2015
Closed
ES200A_5Hardware RequirementsFALSENA



ES200A_34The Current Measurement function shall use a low pass filter with 7.2MHz cutoff frequency to filter the physical motor currents.TRUEDDerived3/17/2015
Closed
ES200A_114The Current Measurement function shall use a ADC module with at least 12-bit of resolution which shall be capable to sample the Physical Motor Current signals ranging from 0.3V to 4.8V at 62.5us (nominal) and convert them into digital signals.
TRUEDDerived3/17/2015
Closed
ES200A_210The Current Measurement function shall use a current sensing opamp to measure each phase current which has following characteristics.
Offset is equal to 2.5V ± 50mV and
Gain is equal to 30V/V ± 1%.
TRUEDDerived3/17/2015
Closed
ES200A_115Range RequirementFALSENA



ES200A_112The Current Measurement function shall be adequate to measure 105% of the max motor peak-peak current.TRUEDDerived3/17/2015
Closed
ES200A_120Resolution RequirementFALSENA



ES200A_117The Current Measurement function shall provide a resolution of 70 mA/count calculated based on the maximum torque ripple allowed in the system.


For a nominal value of Ke = 0.04554957225 V/rad/sec, the required current resolution to meet the torque ripple requirement is

TRUEDDerived3/17/2015
Closed
ES200A_121Accuracy RequirmentFALSENA



ES200A_122The Current Measurement function shall provide a steady state accuracy of ±1.5%
TRUEDDirect3/17/2015
Closed
ES200A_6Software / Algorithm RequirementsFALSENA



ES200A_44Special Execution RequirementsFALSENA



ES200A_246The Current Measurement function shall be executed in every other motor control loop (nominal 125us).TRUEDDerived9/28/2015
Closed
ES200A_45Software Algorithm DecomopositionFALSENA



ES200A_38Sub-Function: End of Line (EOL) Manufacturing CalibrationFALSENA



ES200A_135The Current Measurement function shall have the capability to calibrate offset of the three current sense amplifiers for each inverter.
TRUEDDerived3/17/2015
Closed
ES200A_174The Current Measurement function shall have the capability to calibrate gain of the three current sense amplifiers for each inverter.
TRUEDDerived3/17/2015
Closed
ES200A_136The Current Measurement function shall calculate the offset of the sense amplifier at the manufacturing End-of-Line by setting the current through the sense resistor to zero by placing the motor driver into Off-State, and reading a filtered version of the ADC output.
TRUEDDerived3/17/2015
Closed
ES200A_139The Current Measurement function shall measure the gain of the sense amplifier at the manufacturing End-of-Line by turning the lower MOSFETs ON for 100% and injecting a known DC current through the sense resistor, and reading a filtered version of the ADC output.
TRUEDDerived3/17/2015
Closed
ES200A_138The Current Measurement function shall store the offset calibration values into a persistent storage to further use in the run time offset correction and current processing.
TRUEDDerived3/17/2015
Closed
ES200A_176The Current Measurement function shall store the gain calibration values into a persistent storage to further use in the run time offset correction and current processing.
TRUEDDerived3/17/2015
Closed
ES200A_134Sub-Function: Temperature Based Current Offset AdjustmentFALSENA



ES200A_126The Current Measurement function shall adjust the offset of the sense amplifier based on the TCtrlrFild to compensate the offset drift caused by temperature.
TRUEDDerived3/17/2015
Closed
ES200A_137Sub-Function: Raw Current Processing for Phase A, Phase B, Phase CFALSENA



ES200A_151The Current Measurement function shall generate MotCtrlMotCurrCorrdA in amps from MotCtrlMotCurrAdcVlyA.
TRUEDDirect3/17/2015
Closed
ES200A_150The Current Measurement function shall generate MotCtrlMotCurrCorrdB in amps from MotCtrlMotCurrAdcVlyB.
TRUEDDirect3/17/2015
Closed
ES200A_149The Current Measurement function shall generate MotCtrlMotCurrCorrdC in amps from MotCtrlMotCurrAdcVlyC.
TRUEDDirect3/17/2015
Closed
ES200A_159The Current Measurement function shall update MotCurrQlfr1 to indicate the status of the current sense amplifiers of Gate Drive 1.
TRUEDDirect3/17/2015
Closed
ES200A_157The Current Measurement function shall increment MotCtrlMotCurrRollgCntr1 if diagnostic Current Measurement Protocol Fault for Phase A, B, C is PASSED.
TRUEDDirect3/17/2015
Closed
ES200A_161Sub-Function: Raw Current Processing for Phase D, Phase E, Phase FFALSENA



ES200A_162The Current Measurement function shall perform this Sub-Function if MotCtrlDiagcStsIvtr2Actv = TRUE.
TRUEDDirect3/17/2015
Closed
ES200A_148The Current Measurement function shall generate MotCtrlMotCurrCorrdD in amps from MotCtrlMotCurrAdcVlyD.
TRUEDDirect3/17/2015
Closed
ES200A_147The Current Measurement function shall generate MotCtrlMotCurrCorrdE in amps from MotCtrlMotCurrAdcVlyE.TRUEDDirect3/17/2015
Closed
ES200A_146The Current Measurement function shall generate MotCtrlMotCurrCorrdF in amps from MotCtrlMotCurrAdcVlyF.
TRUEDDirect3/17/2015
Closed
ES200A_158The Current Measurement function shall generate MotCurrQlfr2 to indicate the status of the current sense amplifiers of Gate Drive 2.
TRUEDDirect3/17/2015
Closed
ES200A_179The Current Measurement function shall increment MotCtrlMotCurrRollgCntr2 if diagnostic Current Measurement Protocol Fault for Phase D, E, F is PASSED.
TRUEDDirect3/17/2015
Closed
ES200A_279Sub-Function: NVM Read/Write Service for Offset and Gain Calibration DataFALSENA



ES200A_280The Current Measurement function shall have the capability of writing and reading the offset calibration data to and from the NVM upon performing a range check.
TRUEDDirect9/28/2015
Closed
ES200A_291The Current Measurement function shall have the capability of writing and reading the gain calibration data to and from the NVM upon performing a range check.
TRUEDDirect9/28/2015
Closed
ES200A_7Diagnostic RequirementsFALSENA



ES200A_211Current Measurement Protocol Fault for Phase A, B, C (NTC0x05D)FALSENA



ES200A_212Required Debounce StrategyFALSENA



ES200A_132The Current Measurement function shall use the ISO based error accumulator strategy for NTC0x05D.

Note: The requirements for these strategies are identified in the Diagnostic Manager Functional Requirements documentation and will be tested for complmiance on each NTC in this document.
TRUEDDerived3/17/2015
Closed
ES200A_214Requirements to Perform Diagnostic Test ConditionsFALSENA



ES200A_213The Current Measurement function shall perform the test condition for NTC0x05D in Warm Init and Enable states if MotCtrlDiagcStsIvtr1Inactv = FALSE.
TRUEDDerived3/17/2015
Closed
ES200A_216Test Condition Negative RequirementsFALSENA



ES200A_215The Current Measurement function shall provide a negative result for NTC0x05D if MotCtrlMotCurrAdcVlyA, MotCtrlMotCurrAdcVlyB, MotCtrlMotCurrAdcVlyC signals are NOT within field configurable values during the start-up test.

NOTE:This test condition is linked to parameter bit 0.
TRUEDDerived3/17/2015
Closed
ES200A_293The Current Measurement function shall provide a negative result for NTC0x05D if any of the MotCtrlMotCurrAdcVlyAAdcFaild or MotCtrlMotCurrAdcVlyBAdcFaild or MotCtrlMotCurrAdcVlyCAdcFaild is TRUE when the SysSt = Warm-Init and the CurrMeasWrmIninTestCmpl = TRUE.

NOTE:This test condition is linked to parameter bit 2.
TRUEDDerived3/10/2016
Closed
ES200A_292The Current Measurement function shall provide a negative result for NTC0x05D if any of the MotCtrlMotCurrAdcVlyAAdcFaild or MotCtrlMotCurrAdcVlyBAdcFaild or MotCtrlMotCurrAdcVlyCAdcFaild is TRUE when the SysSt = Enable and the CurrMeasWrmIninTestCmpl = TRUE.

NOTE:This test condition is linked to parameter bit 1.
TRUEDDerived3/10/2016
Closed
ES200A_217Test Condition Positive RequirementsFALSENA



ES200A_177The Current Measurement function shall provide a positive result to the test condition for NTC0x05D when none of the negative result requirements are satisfied.
TRUEDDerived3/17/2015
Closed
ES200A_219Current Measurement Protocol Fault for Phase D, E, F (NTC0x06D)FALSENA



ES200A_221Required Debounce StrategyFALSENA



ES200A_223The Current Measurement function shall use the ISO based error accumulator strategy for NTC0x06D.

Note: The requirements for these strategies are identified in the Diagnostic Manager Functional Requirements documentation and will be tested for complmiance on each NTC in this document.
TRUEDDerived3/17/2015
Closed
ES200A_224Requirements to Perform Diagnostic Test ConditionsFALSENA



ES200A_225The Current Measurement function shall perform the test condition for NTC0x06D in Warm Init and Enable states if the following conditions are TRUE.
MotCtrlDiagcStsIvtr1Inactv = FALSE and
ELECGLBPRM_IVTRCNT_CNT_U08 = 2.
TRUEDDerived3/17/2015
Closed
ES200A_226Test Condition Negative RequirementsFALSENA



ES200A_227The Current Measurement function shall provide a negative result for NTC0x06D if MotCtrlMotCurrAdcVlyD, MotCtrlMotCurrAdcVlyE, MotCtrlMotCurrAdcVlyF signals are NOT within field configurable values during the start-up test.

NOTE:This test condition is linked to parameter bit 0.
TRUEDDerived3/17/2015
Closed
ES200A_295The Current Measurement function shall provide a negative result for NTC0x06D if any of the MotCtrlMotCurrAdcVlyDAdcFaild or MotCtrlMotCurrAdcVlyEAdcFaild or MotCtrlMotCurrAdcVlyFAdcFaild is TRUE when the SysSt = Warm-Init and the CurrMeasWrmIninTestCmpl = TRUE.

NOTE:This test condition is linked to parameter bit 2.
TRUEDDerived3/10/2016
Closed
ES200A_294The Current Measurement function shall provide a negative result for NTC0x06D if any of the MotCtrlMotCurrAdcVlyDAdcFaild or MotCtrlMotCurrAdcVlyEAdcFaild or MotCtrlMotCurrAdcVlyFAdcFaild is TRUE when the SysSt = Enable and the CurrMeasWrmIninTestCmpl = TRUE.

NOTE:This test condition is linked to parameter bit 1.
TRUEDDerived3/10/2016
Closed
ES200A_244Test Condition Positive RequirementsFALSENA



ES200A_245The Current Measurement function shall provide a positive result to the test condition for NTC0x06D when none of the negative result requirements are satisfied.
TRUEDDerived3/17/2015
Closed
ES200A_248Current Measurement Eol Offset Calibration Fault (NTC0x1EC)FALSENA



ES200A_250Required Debounce StrategyFALSENA



ES200A_251The Current Measurement function shall use the ISO based error accumulator strategy for NTC0x1EC.

Note: The requirements for these strategies are identified in the Diagnostic Manager Functional Requirements documentation and will be tested for complmiance on each NTC in this document.
TRUEDDerived3/17/2015
Closed
ES200A_252Requirements to Perform Diagnostic Test ConditionsFALSENA



ES200A_253The Current Measurement function shall perform the test conditions for NTC0x1EC ONLY during offset calibration process.TRUEDDerived3/17/2015
Closed
ES200A_254Test Condition Negative RequirementsFALSENA



ES200A_255The Current Measurement function shall provide a negative result for NTC0x1EC if MotCurrOffsHiAvrgA, MotCurrOffsHiAvrgB, MotCurrOffsHiAvrgC, MotCurrOffsLoAvrgA, MotCurrOffsLoAvrgB. MotCurrOffsLoAvrgC are NOT within field configurable values.
TRUEDDerived3/17/2015
Closed
ES200A_296The Current Measurement function shall provide a negative result for NTC0x1EC if MotCurrOffsHiAvrgD, MotCurrOffsHiAvrgE, MotCurrOffsHiAvrgF, MotCurrOffsLoAvrgD, MotCurrOffsLoAvrgE, MotCurrOffsLoAvrgF are NOT within field configurable values.
TRUEDDerived3/17/2015
Closed
ES200A_297The Current Measurement function shall provide a negative result for NTC0x1EC if the following conditions are NOT met during the Offset calibration process:
VehSpd = 0,
VehSpdVld = 1
MotVelMrf < A Fireld configurable value
TRUEDDerived3/17/2015
Closed
ES200A_301The Current Measurement function shall provide a negative result for NTC0x1EC if the following conditions are met during the offset calibration process:
DiagcStsIvtr1Inactv = TRUE & DiagcStsIvtr2Inactv = TURE.
TRUEDDerived3/17/2015
Closed
ES200A_256Test Condition Positive RequirementsFALSENA



ES200A_257The Current Measurement function shall provide a positive result to the test condition for NTC0x1EC when none of the negative result requirements are satisfied.
TRUEDDerived3/17/2015
Closed
ES200A_258Current Measurement Eol Gain Calibration Fault (NTC0x1ED)FALSENA



ES200A_259Required Debounce StrategyFALSENA



ES200A_260The Current Measurement function shall use the ISO based error accumulator strategy for NTC0x1ED.

Note: The requirements for these strategies are identified in the Diagnostic Manager Functional Requirements documentation and will be tested for complmiance on each NTC in this document.
TRUEDDerived3/17/2015
Closed
ES200A_261Requirements to Perform Diagnostic Test ConditionsFALSENA



ES200A_262The Current Measurement function shall perform the test conditions for NTC0x1ED ONLY during gain calibration process.TRUEDDerived3/17/2015
Closed
ES200A_263Test Condition Negative RequirementsFALSENA



ES200A_264The Current Measurement function shall provide a negative result for NTC0x1ED if MotCurrEolGainA, MotCurrEolGainB, MotCurrEolGainC are NOT within field configurable values.
TRUEDDerived3/17/2015
Closed
ES200A_299The Current Measurement function shall provide a negative result for NTC0x1ED if MotCurrEolGainD, MotCurrEolGainE, MotCurrEolGainF are NOT within field configurable values.
TRUEDDerived3/17/2015
Closed
ES200A_298The Current Measurement function shall provide a negative result for NTC0x1ED if the following conditions are NOT met during the Gain calibration process:
VehSpd = 0,
VehSpdVld = 1
MotVelMrf < A Fireld configurable value
TRUEDDerived3/17/2015
Closed
ES200A_300The Current Measurement function shall provide a negative result for NTC0x1ED if the following conditions are met during the Gain calibration process:
DiagcStsIvtr1Inactv = TRUE & DiagcStsIvtr2Inactv = TURE.
TRUEDDerived3/17/2015
Closed
ES200A_265Test Condition Positive RequirementsFALSENA



ES200A_266The Current Measurement function shall provide a positive result to the test condition for NTC0x1ED when none of the negative result requirements are satisfied.
TRUEDDerived3/17/2015
Closed
ES200A_8Manufacturing RequirementsFALSENA



ES200A_32NoneFALSENA