GuardCfgAndDiagc Integration Manual

Integration Manual

For

GuardCfgAndDiagc

VERSION: 1

DATE: 02/16/16

Prepared By:

Software Group,

Nexteer Automotive,

Saginaw, MI, USA

Location: The official version of this document is stored in the Nexteer Configuration Management System.

Revision History

Sl. No.DescriptionAuthorVersionDate
1Initial versionAvinash James102/16/16

Table of Contents

1 Abbrevations And Acronyms 4

2 References 5

3 Dependencies 6

3.1 SWCs 6

3.2 Global Functions(Non RTE) to be provided to Integration Project 6

4 Configuration REQUIREMeNTS 7

4.1 Build Time Config 7

4.2 Configuration Files to be provided by Integration Project 7

4.3 Da Vinci Parameter Configuration Changes 7

4.4 DaVinci Interrupt Configuration Changes 7

4.5 Manual Configuration Changes 7

5 Integration DATAFLOW REQUIREMENTS 8

5.1 Required Global Data Inputs 8

5.2 Required Global Data Outputs 8

5.3 Specific Include Path present 8

6 Runnable Scheduling 9

7 Memory Map REQUIREMENTS 10

7.1 Mapping 10

7.2 Usage 10

7.3 NvM Blocks 10

8 Compiler Settings 11

8.1 Preprocessor MACRO 11

8.2 Optimization Settings 11

9 Appendix 12

Abbrevations And Acronyms

AbbreviationDescription
DFDDesign functional diagram
MDDModule design Document
FDDFunctional Design Document

References

This section lists the title & version of all the documents that are referred for development of this document

Sr. No.TitleVersion
1FDD – CM107A GuardCfgAndDiagcSee Synergy subproject version
2Software Naming ConventionsProcess 04.02.00
3Software Coding StandardsProcess 04.02.00

Dependencies

SWCs

ModuleRequired Feature
AR202A MicroCtrlrSuprtNxtrMcuSuprtLib functions and register definitions

Note : Referencing the external components should be avoided in most cases. Only in unavoidable circumstance external components should be referred. Developer should track the references.

Global Functions(Non RTE) to be provided to Integration Project

GuardCfgAndDiagcInit1 - Non-RTE function so that guard protection can be initialized and enabled before the RTE is started

IpgInin - To be configured as a trusted function because it needs to run in supervisor mode

GuardCfgAndDiagcInit3 - Non-RTE function so that guard startup test can be run before the RTE is started

Configuration REQUIREMeNTS

Build Time Config

ModulesNotes
None

Configuration Files to be provided by Integration Project

Da Vinci Parameter Configuration Changes

ParameterNotesSWC

DaVinci Interrupt Configuration Changes

ISR NameVIM #Priority DependencyNotes

Manual Configuration Changes

ConstantNotesSWC
None

Integration DATAFLOW REQUIREMENTS

Required Global Data Inputs

None

Required Global Data Outputs

None

Specific Include Path present

Yes

Runnable Scheduling

This section specifies the required runnable scheduling.

InitScheduling Requirements
GuardCfgAndDiagcInit1Non-RTE Init, Called in Startup Sequence*Function call in Startup Sequence
GuardCfgAndDiagcInit2RTEOnce At Init (RTE)
GuardCfgAndDiagcInit3Non-RTE Init, Called in Startup Sequence*Function call in Startup Sequence

*Refer CM100A for the start up sequence

RunnableScheduling RequirementsTrigger

.

Memory Map REQUIREMENTS

Mapping

Memory SectionContentsNotes
CDD_GuardCfgAndDiagc_START_SEC_CODE

* Each …START_SEC… constant is terminated by a …STOP_SEC… constant as specified in the AUTOSAR Memory Mapping requirements.

Usage

FeatureRAMROM

Table 1: ARM Cortex R4 Memory Usage

NvM Blocks

Compiler Settings

Preprocessor MACRO

None

Optimization Settings

None

Appendix

None

Last modified October 12, 2025: Initial commit (1fadfc4)