MotTqTranlDampg_MDD
Module Design Document
For
Transistional Damping (SF-50A)
August 12, 2015
Prepared For:
Software Engineering
Nexteer Automotive,
Saginaw, MI, USA
Prepared By:
Krishna Kanth Anne,
Nexteer Automotive,
Saginaw, MI, USA
Change History
Description | Author | Version | Date |
Initial Version | Krishna Kanth Anne | EA4 01.00.01 | 12-Aug-2015 |
Table of Contents
2 MotTqTranlDampg & High-Level Description 6
3 Design details of software module 7
3.1 Graphical representation of MotTqTranlDampg 7
4.1 Program (fixed) Constants 9
5 Software Component Implementation 10
5.1.1 Init: MotTqTranlDampgInit1 10
5.1.2 Per: MotTqTranlDampgPer1 10
5.1.2.2 Store Module Inputs to Local copies 10
5.1.2.3 (Processing of function)……… 10
5.1.2.4 Store Local copy of outputs into Module Outputs 10
5.4 Module Internal (Local) Functions 10
5.5 GLOBAL Function/Macro Definitions 11
6 Known Limitations with Design 12
Appendix A Abbreviations and Acronyms 14
Introduction
Purpose
MDD for Motor Torque Transistional Damping.
Scope
MotTqTranlDampg & High-Level Description
Please refer FDD.
Design details of software module
Graphical representation of MotTqTranlDampg
Data Flow Diagram
Please refer FDD.
Component level DFD
Function level DFD
Constant Data Dictionary
Program (fixed) Constants
Embedded Constants
Local Constants
Constant Name | Resolution | Units | Value |
---|---|---|---|
Please refer .m file |
Software Component Implementation
Sub-Module Functions
Init: MotTqTranlDampgInit1
Design Rationale
None
Module Outputs
None
Per: MotTqTranlDampgPer1
Design Rationale
None
Store Module Inputs to Local copies
Please refer FDD
(Processing of function)………
Please refer FDD
Store Local copy of outputs into Module Outputs
Please refer FDD
Server Runables
None
Interrupt Functions
None
Module Internal (Local) Functions
Local Function #1
Function Name | SwOpCtrlPart1 | Type | Min | Max |
Arguments Passed | TranlDampgTiElpsd_MilliSec_T_f32 | float32 | 0.0 | 1000.0 |
AbslMotVelCrf_MotRadPerSec_T_f32 | float32 | 0.0 | 1350.0 | |
Return Value | MotTqTranlDampgCmpl_Cnt_T_lgc | boolean | FALSE | TRUE |
Design Rationale
None
Processing
(Place flowchart/design for local function)
Refer to the “SwOutputCntrl” block of the Simulink model of the design.
Local Function #2
Function Name | SwOpCtrlPart2 | Type | Min | Max |
Arguments Passed | DiagcStsCtrldShtDwnFltPrsnt_Cnt_T_lgc | boolean | FALSE | TRUE |
CtrlDampTrq_MotNwtMtr_T_f32 | float32 | -3.0 | 3.0 | |
SysSt_Cnt_T_enum | SysSt1 | 0 | 3 | |
MotTqCmdCrf_MotNwtMtr_T_f32 | float32 | -8.8 | 8.8 | |
MotTqTranlDampgCmpl_Cnt_T_lgc | boolean | FALSE | TRUE | |
Return Value | MotTqCmdCrfDampd_MotNwtMtr_T_f32 | float32 | -11.8 | 11.8 |
Design Rationale
None
Processing
(Place flowchart/design for local function)
Refer to the “SwOutputCntrl” block of the Simulink model of the design.
GLOBAL Function/Macro Definitions
None
GLOBAL Function #1
Function Name | NA | Type | Min | Max |
Arguments Passed | None | |||
Return Value | NA |
Known Limitations with Design
None
UNIT TEST CONSIDERATION
None
Abbreviations and Acronyms
Abbreviation or Acronym | Description |
---|---|
Glossary
Note: Terms and definitions from the source “Nexteer Automotive” take precedence over all other definitions of the same term. Terms and definitions from the source “Nexteer Automotive” are formulated from multiple sources, including the following:
ISO 9000
ISO/IEC 12207
ISO/IEC 15504
Automotive SPICE® Process Reference Model (PRM)
Automotive SPICE® Process Assessment Model (PAM)
ISO/IEC 15288
ISO 26262
IEEE Standards
SWEBOK
PMBOK
Existing Nexteer Automotive documentation
Term | Definition | Source |
---|---|---|
MDD | Module Design Document | |
DFD | Data Flow Diagram |
References
Ref. # | Title | Version |
---|---|---|
1 | AUTOSAR Specification of Memory Mapping (Link:AUTOSAR_SWS_MemoryMapping.pdf) | v1.3.0 R4.0 Rev 2 |
2 | MDD Guideline | EA4 01.00.00 |
3 | Software Naming Conventions.doc | 1.0 |
4 | Software Design and Coding Standards.doc | 2.0 |
5 | FDD : SF050A_MotTqTranlDampg_Design (V 1.1.0) | See Synergy sub project version |