1 - CM101A_ExcpnHndlg

Exception Handling

(ExcpnHndlg)

FDD CM101A

1. High Level Description 6

2. Sub-Functions In This Document 8

3. Critical Register Verification References 9

4. Sub-functions 10

4.1. Sub-Function: Exception Handling Configuration 10

4.1.1. NTCs 10

4.1.2. SAN Linkage 10

4.1.3. Description 10

4.1.4. Rationale 10

4.1.5. Implementation 10

4.1.6. Reference 12

4.1.7. Diagnostic Verification Method 13

4.2. Sub-Function: Exception Handling Routine SYSERR 14

4.2.1. NTCs 14

4.2.2. SAN Linkage 14

4.2.3. Description 14

4.2.4. Rationale 14

4.2.5. Implementation 15

4.2.6. Reference 17

4.2.7. Verification Method 20

4.3. Sub-Function: Exception Handling Routine Floating Point 20

4.3.1. NTCs 20

4.3.2. SAN Linkage 20

4.3.3. Description 20

4.3.4. Rationale 20

4.3.5. Implementation 20

4.3.6. Reference 22

4.3.7. Verification Method 24

4.4. Sub-Function: Exception Handling Routine Misalignment 25

4.4.1. NTCs 25

4.4.2. SAN Linkage 25

4.4.3. Description 25

4.4.4. Rationale 25

4.4.5. Implementation 25

4.4.6. Reference 26

4.4.7. Verification Method 27

4.5. Sub-Function: Exception Handling Routine Reserved Instruction 28

4.5.1. NTCs 28

4.5.2. SAN Linkage 28

4.5.3. Description 28

4.5.4. Rationale 28

4.5.5. Implementation 28

4.5.6. Verification Method 28

4.6. Sub-Function: Server Routine FENMI PEG 29

4.6.1. NTCs 29

4.6.2. SAN Linkage 29

4.6.3. Description 29

4.6.4. Rationale 29

4.6.5. Implementation 29

4.6.6. Verification Method 29

4.7. Sub-Function: Server Routine FENMI SPI 2 Bit ECC Error 30

4.7.1. NTCs 30

4.7.2. SAN Linkage 30

4.7.3. Description 30

4.7.4. Rationale 30

4.7.5. Implementation 30

4.7.6. Reference 32

4.7.7. Verification Method 34

4.8. Sub-Function: Server Routine FENMI DMA Transfer Error 35

4.8.1. NTCs 35

4.8.2. SAN Linkage 35

4.8.3. Description 35

4.8.4. Rationale 35

4.8.5. Implementation 35

4.8.6. Reference 36

4.8.7. Verification Method 36

4.9. Sub-Function: Server Routine FENMI DMA Access Violation Error 37

4.9.1. NTCs 37

4.9.2. SAN Linkage 37

4.9.3. Description 37

4.9.4. Rationale 37

4.9.5. Implementation 37

4.9.6. Reference 38

4.9.7. Verification Method 38

4.10. Sub-Function: Server Routine FENMI ECM Master/Checker Compare 39

4.10.1. NTCs 39

4.10.2. SAN Linkage 39

4.10.3. Description 39

4.10.4. Rationale 39

4.10.5. Implementation 39

4.10.6. Verification Method 39

4.11. Sub-Function: Server Routine FENMI Watchdog 40

4.11.1. NTCs 40

4.11.2. SAN Linkage 40

4.11.3. Description 40

4.11.4. Rationale 40

4.11.5. Implementation 40

4.11.6. Verification Method 41

4.12. Sub-Function: FENMI Clock Monitor 0 RunTime Lower Limit Fault 42

4.12.1. NTCs 42

4.12.2. SAN Linkage 42

4.12.3. Description 42

4.12.4. Rationale 42

4.12.5. Implementation 42

4.12.1. Verification Method 42

4.13. Sub-Function: FENMI Clock Monitor 0 RunTime Upper Limit Fault 42

4.13.1. NTCs 42

4.13.2. SAN Linkage 42

4.13.1. Description 43

4.13.2. Rationale 43

4.13.3. Implementation 43

4.13.4. Verification Method 43

4.14. Sub-Function: FENMI Clock Monitor 1 RunTime Lower Limit Fault 43

4.14.1. NTCs 43

4.14.2. SAN Linkage 43

4.14.1. Description 43

4.14.2. Rationale 43

4.14.3. Implementation 44

4.14.4. Verification Method 44

4.15. Sub-Function: FENMI Clock Monitor 1 RunTime Upper Limit Fault 44

4.15.1. NTCs 44

4.15.2. SAN Linkage 44

4.15.3. Description 44

4.15.4. Rationale 44

4.15.5. Implementation 44

4.15.6. Verification Method 45

4.16. Sub-Function: FENMI Clock Monitor 2 RunTime Lower Limit Fault 45

4.16.1. NTCs 45

4.16.2. SAN Linkage 45

4.16.3. Description 45

4.16.4. Rationale 45

4.16.5. Implementation 45

4.16.6. Verification Method 45

4.17. Sub-Function: FENMI Clock Monitor 2 RunTime Upper Limit Fault 45

4.17.1. NTCs 45

4.17.2. SAN Linkage 45

4.17.3. Description 46

4.17.4. Rationale 46

4.17.5. Implementation 46

4.17.6. Verification Method 46

4.18. Sub-Function: FENMI Clock Monitor 3 RunTime Lower Limit Fault 46

4.18.1. NTCs 46

4.18.2. SAN Linkage 46

4.18.3. Description 46

4.18.4. Rationale 46

4.18.5. Implementation 47

4.18.6. Verification Method 47

4.19. Sub-Function: FENMI Clock Monitor 3 RunTime Upper Limit Fault 47

4.19.1. NTCs 47

4.19.2. SAN Linkage 47

4.19.3. Description 47

4.19.4. Rationale 47

4.19.5. Implementation 47

4.19.6. Verification Method 48

4.20. Sub Function: Server Routine Process Unknown Exception Error 48

4.20.1. NTCs 48

4.20.2. SAN Linkage 48

4.20.3. Description 48

4.20.4. Rationale 48

4.20.5. Implementation 48

4.20.6. Verification Method 48

4.21. Sub-Function: Server Routine Process Memory Protection Unit Exception Error 49

4.21.1. NTCs 49

4.21.2. SAN Linkage 49

4.21.3. Description 49

4.21.4. Rationale 49

4.21.5. Implementation 49

4.21.6. Verification Method 49

4.22. Sub-Function: Server Routine Process Privileged Instruction Exception Error 49

4.22.1. NTCs 49

4.22.2. SAN Linkage 49

4.22.3. Description 49

4.22.4. Rationale 50

4.22.5. Implementation 50

4.22.6. Verification Method 50

4.23. Sub-Function: Server Routine Process Permanent Os Error 50

4.23.1. NTCs 50

4.23.2. SAN Linkage 50

4.23.3. Description 50

4.23.4. Rationale 50

4.23.5. Implementation 50

4.23.6. Verification Method 50

4.24. Sub-Function: Server Routine Process Non Critical Os Error 50

4.24.1. NTCs 50

4.24.2. SAN Linkage 50

4.24.3. Description 51

4.24.4. Rationale 51

4.24.5. Implementation 51

4.24.6. Verification Method 51

4.24.7. Periodic (ExcpnHndlgPer1) 51

4.24.8. Verification Method 51

4.25. Sub-Function: Server Routine Shutdown Hook 52

4.26. Sub-Function: Exception Handling Routine EIINT 52

4.27. Sub-Function: Reset Source Determination 53

4.27.1. NTCs 53

4.27.2. SAN Linkage 54

4.27.3. Description 54

4.27.4. Rationale 54

4.27.5. Implementation 55

4.27.6. Verification Method 61

5. Special Functions 61

6. Revision Record & Change Approval 63

High Level Description

This document describes the exception handling / reset cause determination for microcontroller diagnostics. Note that the MCU handler is in place to parse / identify FE and EI exception sources (of the 43 shown). The MCU will call server functions in this FDD for FE type interrupts. EI based interrupts will call server functions directly to the FDD.

Additionally, any pre-OS type failures that are detected are “saved” using backup RAM until the reset cause functionality is performed. The reset cause algorithm uses the backup RAM (modified by both Exceptions and pre-OS start up tests) to set appropriate fault codes. For this FDD, NTCs are only set in the reset cause function.

Sub-Functions In This Document

Below is a linked list of all sub-functions owned by this document.

Sub-Function NameLink
Exception Handling Configuration4.1
Exception Handling Routine SYSERR4.2
Exception Handling Routine Floating Point4.3
Exception Handling Routine Misalignment4.4
Exception Handling Routine Reserved Instruction4.5
Server Routine FENMI PEG4.6
Server Routine FENMI SPI 2 Bit ECCError: Reference source not found
Server Routine FENMI DMA Transfer Error4.7
Server Routine FENMI DMA Access Violation Error4.8
Server Routine FENMI Master Checker Compare4.9
Server Routine FENMI Watchdog4.10
Server Routine FENMI DTS Double Bit ECC4.11
Server Routine FENMI Clock Monitor 0 RunTime Lower Limit Fault
Server Routine FENMI Clock Monitor 0 RunTime Upper Limit Fault
Server Routine FENMI Clock Monitor 1 RunTime Lower Limit Fault
Server Routine FENMI Clock Monitor 1 RunTime Upper Limit Fault
Server Routine FENMI Clock Monitor 2 RunTime Lower Limit Fault
Server Routine FENMI Clock Monitor 2 RunTime Upper Limit Fault
Server Routine FENMI Clock Monitor 3 RunTime Lower Limit Fault
Server Routine FENMI Clock Monitor 3 RunTime Upper Limit Fault
Server Routine FENMI UnknownError: Reference source not found
Server Routine Protection HookError: Reference source not found
Server Routine Error Hook4.23
Server Routine Shutdown Hook4.27
Exception Handling Routine EIINTError: Reference source not found
Reset Source Determination4.29

Critical Register Verification References

This table contains the information needed for critical register verification as configured or used in this document.

Register

Register No.

(regID, selID)

Access Permission

Init / Periodic

Verification

MaskingExpected ValueProtn Score From Eval Sheet
FPCFGSR10, 0CU0InitNone0x0000 001C0

Sub-functions

Sub-Function: Exception Handling Configuration

Return to sub-function list link: Sub-Functions In This Document

NTCs

NA

SAN Linkage

SAN-49: After reset the generation of SYSERR exception request due to the errors shown in the Error notification Control Register (SEGCONT) is disabled. This notification can be enabled by setting the related bits accordingly.

SAN-263: Generation of SYSERR exception in case of uncorrectable error (e.g. DED, Address parity) during instruction fetch cannot be masked for instruction fetch unit in SEGCONT. However, such errors shall be always handled by ECM within DTI.

SAN-278: Transition to the safe state shall take place when an ECC 2-bit error, or an overflow error has occurred. For this purpose, the ECM shall be configured accordingly.

SAN-342: Transition the MCU and the system to the safe state shall take place when an address parity error has occurred. For this purpose, the ECM shall be configured accordingly.

SAN-401: Transition to the safe state shall take place when 2-bits error, an error count overflow or an address error has been detected. For this purpose, configure the appropriate response in the ECM accordingly.

SAN-413: Upon detection of non-correctable bit error in the local RAM, a system error exception request will be sent to SEG to generate a SYSERR (FE-level) exception (if it is enabled).

Description

This sub-function configures or identifies the exception handling characteristics for the RH850 related to microcontroller diagnostics.

Rationale

The Nexteer approach planned for exception handling involves two types – those serious errors that will be handled by forcing a software reset of the microcontroller and those that do not. This sub-function is intended to show the list of exceptions and highlight those that will be configured to be a system error (SYSERR) via the use of the SEGCONT register. Floating point exceptions must also be configured.

Exception Handler assumes that the MCAL will configure the CVMREN register to cause a reset when the CVM Fails.

Implementation

Initialization (ExcpnHndlgInit1)

Register Configuration Summary

RegisterValueCommentsAccess
SVUM
FPCFG (Floating-point operation configuration)

FPCFG.XE.V = 1 (Validity)

FPCFG.XE.Z = 1 (Divide by Zero)

FPCFG.XE.O = 1 (Overflow)

FPCFG.XE.U = 0 (Underflow)

FPCFG.XE.I = 0 (Imprecise)

Only addresses configuring the exception bitsR/WR/W
* SYSCVMDEW (CVM Detection Enable Register)SYSCVMDEW. CVMDIAGMEW = 0

Enable CVM Diagnosis

NOTE: This is a protected register. Can only be written to once.

R/WR/W

*Denotes that no direct write is required as the default value meets the requirement.

NOTE: MCU configuration has a checkbox selection for the self-test – consider this in the future design.

// Configure floating point exceptions – note that other FPU configuration is done in the FBL

FPCFG = 0x0000 001C

Reference

FPSR (See boot loader CM110A for configuration function):

Bits 31 to 24: Status bits – NA for configuration – initialize to zero

Bit 23: FN Flush to Nearest: recommend setting this bit to 1 – along with the FS (Flush Subnormal) bit set to 1 and the RM bits set to RN (round to nearest) , this setting will cause subnormal numbers to be flushed to either zero or +/- the smallest magnitude normal number, whichever is closer to the subnormal result – essentially rounds the subnormal result rather than flushing to zero always. (See FS setting for EA3 comparison)

Bit 22: IF: status bit – NA for configuration – initialize to zero

Bit 21: PEM: recommend setting to 0 – for imprecise floating point exceptions. This does not allow resuming execution after the exception handler, which is ok since the expected design is to cause a reset. Precise exceptions would allow resuming execution but causes slower operation (different pipelining to allow for precise exceptions).

Bit 20: Reserved: must write a 0

Bits 19 and 18: RM, rounding mode, recommend setting is 00 for RN round to nearest. This matches the setting used in EA3.

Bit 17: FS flush subnormal – recommend setting this bit to 1 to enable flush subnormal. This is the default setting of this bit. The floating point coprocessor does not have hardware processing of subnormal numbers; therefore if FS is disabled, any subnormal operand or result causes an exception so that software processing can occur; recommend flush subnormal for throughput optimization. NOTE that this differs from the EA3 setting. The EA3 processor has hardware support for subnormal number processing and we do not flush subnormal numbers; not flushing is the default setting for the EA3 processor.

Bit 16: reserved: must write a 0

Bits 15 to 10: Status bits – NA for configuration – initialize to zero

Bits 9 to 5: Exception enable bits: recommend setting as in EA3 FDD (although no EA3 program has turned these settings on yet)

Bit 9 – V – invalid operation – set to 1 to enable exception

Bit 8 – Z – divide by zero – set to 1 to enable exception

Bit 7 – O – overflow – set to 1 to enable exception

Bit 6 – U – underflow – set to 0 to disable exception

Bit 5 – I – inexact – set to 0 to disable exception

Bits 4 to 0: Status bits – NA for configuration – initialize to zero

Diagnostic Verification Method

NA as this is a configuration sub-function

Sub-Function: Exception Handling Routine SYSERR

Return to sub-function list link: Sub-Functions In This Document

NTCs

None – NTCs are addressed in section 4.29 (Reset Source)

SAN Linkage

SAN-166: If SYSERR exception is generated, a reset of the device shall be issued.

SAN-263: Generation of SYSERR exception in case of uncorrectable error (e.g. DED, Address parity) during instruction fetch cannot be masked for instruction fetch unit in SEGCONT. However, such errors shall be always handled by ECM within DTI.

SAN-278: Transition to the safe state shall take place when an ECC 2-bit error, or an overflow error has occurred. For this purpose, the ECM shall be configured accordingly.

SAN-342: Transition the MCU and the system to the safe state shall take place when an address parity error has occurred. For this purpose, the ECM shall be configured accordingly.

SAN-343: In case an address parity error has occurred, a system error (SYSERR) exception will be generated. This exception is terminating and a reset from the ECM or from the pin becomes necessary.

SAN-401: Transition to the safe state shall take place when 2-bits error, an error count overflow or an address error has been detected. For this purpose, configure the appropriate response in the ECM accordingly.

SAN-413: Upon detection of non-correctable bit error in the local RAM, a system error exception request will be sent to SEG to generate a SYSERR (FE-level) exception (if it is enabled).

SAN-P1x-0703:

In case ECC 1-bit error has occurred, a CRC test [SAN-P1x-0703] shall be executed to check whether or not the error is due single bit or multi-bit corruption that is potentially caused by address decoder failure.

SAN-P1x-1307:

In case an ECC 2-bit has occurred, the related flag will set in DTSER2 register and an internal error signal will be generated towards ECM to take proper action. Moreover, the handling of the DMA transfer request is terminated without executing a DMA cycle and TI write back. In that case the MCU shall be moved into safe state unless the application has implemented further measures to allow the operation to continue.

Description

This sub-function handles the SYSERR exceptions (after the RBASE / EBASE Switch - refer to start up sequence).

Note that some errors are configured to generate a SYSERR based on the contents of the SEGCONT register (see CM110A for details). The design stores information into back up registers, generates a software reset and then the “Reset Source Determination” sub-function identifies the source of the reset and identifies the NTC.

SYSERRs occurring prior to the RTE initialization will result in an interrupt restarting the FBL.

Rationale

SYSERR approach was selected over ECM as it seems to be a more direct response in cases of serious failures. Note that the ECM error out pin is also configured to go the safe state as another redundant disabling mechanism; however, no EI or FE interrupts are configured as enabled.

Design assumes that if none of the SEGFLAG bits are set, then the assumption is an instruction fetch failure.

R7F701311 has 128KB of RAM with a Base address of 0xFEB8 0000 and the Offset starting at 0x0006 0000.

If TCMF flag was set due to uncorrectable ECC error to local RAM or due to an access to RAM-unimplemented area, it can be determined which source caused the error by looking at the local RAM 1st error status register LR1STERSTR_PE1 flags. If any of the status flags are set in this register then TCMF setting was due to ECC error, otherwise TCMF setting was due to access to RAM-unimplemented area.

Because VCIE is configured to trigger a SYSERR (corresponding bit in SEGCONT = 1), all peripheral data bus parity errors will cause a SYSERR.  SYSERR handling must include a software reset -- it is not possible to return from a SYSERR interrupt.  Therefore, the Nexteer design responds to all peripheral data bus parity errors, regardless of which peripheral they occur on, by pulling the ERROROUT pin low (through an ECM configuration), setting a reset cause, and performing a software reset; after the reset, the reset cause will be used to set an NTC.  Since the reset must happen due to the SYSERR handling, there is no benefit in checking the 40-some peripheral registers to determine whether the error occurred on a safety-critical or non-critical peripheral.

The NTC Master List has 2 separate NTCs for safety-critical and non-critical peripheral registers. We choose to implement only the NTC for safety-critical peripheral for the reason mentioned above and not to differentiate between the peripherals.

SAN states “In case ECC 1-bit error has occurred, a CRC test [SAN-P1x-0703] shall be executed to check whether or not the error is due single bit or multi-bit corruption that is potentially caused by address decoder failure.” Nexteer does not perform any CRC calculation on code flash at run time. We disable single bit ECC correction on code flash. Therefore we configure the code flash single bit ECC as a SYSERR through VCIF.

Reasons:

  • Cannot differentiate code flash ECC and address decoder failure.

  • More work needs to be done on DTS channel usage before using DTS to calculate CRC at run time.

  • Excessive bus load at run time

Implementation

The SYSERR exception has an offset of 0x010.

Event Driven (SysErrIrq)

Registers used

RegisterUseRegister Access
SVUM
SEGFLAG (Error Occurrence Retention Register)Contains bits to indicate the source of the system error.R/W

Read

Only

SEGADDR (Error Address)Contains the error address information that caused the system error.R/W

Read

Only

CF1STEADR0_PE1 (Code Flash 1st Error Address Register)Register provides information on address of failure – used for debug purposesR/WR/W

TmpData = 0

// Determine source of error from the SEGFLAG bits and indicate in BRAMDAT0

If (SEGVPGF = 1) Then

TmpSrc = McuDiagc1.MCUDIAGC_PRPHLBUSGUARD

ElseIf (SEGVCRF = 1) Then

TmpSrc = McuDiagc1.MCUDIAGC_INTPRPHLGUARD

ElseIf (SEGTCMF = 1) Then

// Identify bank that failed to get address information from the correct register

If (ECCCPU1DEDF0 = 1) Then

// TmpData is the Offset Address of Local RAM ‘OR’ed with Base Addr (0xFEB8 0000) and Bank Addr (0x0)

TmpData = ((ECCCPU1LR1STEADR0_PE1 << 4) | 0xFEB8 0000)

TmpSrc = McuDiagc1.MCUDIAGC_LCLRAMDBLBIT

Else If (ECCCPU1DEDF1 = 1)

// TmpData is the Offset Address of Local RAM ‘OR’ed with Base Addr (0xFEB8 0000) and Bank Addr (0x4)

TmpData = ((ECCCPU1LR1STEADR1_PE1 << 4) | 0xFEB8 0004)

TmpSrc = McuDiagc1.MCUDIAGC_LCLRAMDBLBIT

Else If (ECCCPU1DEDF2 = 1)

// TmpData is the Offset Address of Local RAM ‘OR’ed with Base Addr (0xFEB8 0000) and Bank Addr (0x8)

TmpData = ((ECCCPU1LR1STEADR2_PE1 << 4) | 0xFEB8 0008)

TmpSrc = McuDiagc1.MCUDIAGC_LCLRAMDBLBIT

Else If (ECCCPU1DEDF3 = 1)

// TmpData is the Offset Address of Local RAM ‘OR’ed with Base Addr (0xFEB8 0000) and Bank Addr (0xC)

TmpData = ((ECCCPU1LR1STEADR3_PE1 << 4) | 0xFEB8 000C)

TmpSrc = McuDiagc1.MCUDIAGC_LCLRAMDBLBIT

Else

// Else TCMF setting was due to access to RAM-unimplemented area.

TmpSrc = McuDiagc1.MCUDIAGC_INVLDRAMAREA

EndIf

ElseIf ((SEGROMF = 1) or (SEGVCIF = 1)) Then // Both bits have code flash ECC

If (ECCFLICF1STERSTR_PE1 & 0x0000 0004 !=0) Then

TmpSrc = McuDiagc1.MCUDIAGC_ADRPAR

TmpData = ECCFLICF1STEADR0_PE1

Else If (ECCFLICF1STERSTR_PE1 & 0x0000 0002 !=0) Then

TmpSrc = McuDiagc1.MCUDIAGC_CODFLSDBLBIT

TmpData = ECCFLICF1STEADR0_PE1

Else If (ECCFLICF1STERSTR_PE1 & 0x0000 0001 !=0) Then

TmpSrc = McuDiagc1.MCUDIAGC_CODFLSECCSNGBITERR

TmpData = ECCFLICF1STEADR0_PE1

Else If (ECCFLICF1STERSTR_VCI & 0x0000 0004 !=0) Then

TmpSrc = McuDiagc1.MCUDIAGC_ADRPAR

TmpData = ECCFLICF1STEADR0_VCI

Else If (ECCFLICF1STERSTR_VCI & 0x0000 0002 !=0) Then

TmpSrc = McuDiagc1.MCUDIAGC_CODFLSDBLBIT

TmpData = ECCFLICF1STEADR0_VCI

Else If (ECCFLICF1STERSTR_VCI & 0x0000 0001 !=0) Then

TmpSrc = McuDiagc1.MCUDIAGC_CODFLSECCSNGBITERR

TmpData = ECCFLICF1STEADR0_VCI Else If (ECMMESSTR0 & 0x1000 0000 != 0)

TmpSrc = McuDiagc1.MCUDIAGC_PRPHLBUSDATAPAR

Else If (DMASSDTSER2 & 0x8000 0000 != 0)

TmpSrc = McuDiagc1. MCUDIAGC_DTSDBLBIT

TmpData = DMASSDTSER2

Else

// Other VCIE cause

TmpSrc = McuDiagc1.MCUDIAGC_VCIE

End If

Else

// Assume instruction fetch error drove SYSERR

TmpSrc = McuDiagc1.MCUDIAGC_INSTRFETCH

End If

NxtrSwRstFromExcpn (TmpSrc, TmpData)

Reference

Verification Method

At 2ms rate:

// Invokes a double bit ECC code flash fault

If ((McuDiagcTest = McuDiagcTestTyp.CODFLSDBLBIT)

Temp = Read from Code Flash Test Address 0x0100 A8B0 // invokes a double bit ECC

McuDiagcTest = McuDiagcTestTyp.NoTest

EndIf

// Check on section 8.4.2 in SAN for address parity fault injection options

// Need to find other ways to invoke a SYSERR

Sub-Function: Exception Handling Routine Floating Point

Return to sub-function list link: Sub-Functions In This Document

NTCs

None – NTCs are addressed in section 4.29 (Reset Source)

SAN Linkage

None identified

Description

This sub-function is used to handle the exceptions configured for the floating point unit (FPU). Based on the configurations, the handler can identify / discriminate faults for overflow, divide by zero and invalid operations.

Rationale

The FPU “E bit” functionality is a function of the FPU configuration.

Page 173/174 of the software user manual (R01UH0436EJ0100 Rev.1.00) states - "If the FS bit of the FPSR register is set to 1, an unimplemented operation exception (E) will not occur under any circumstances."

Nexteer is setting the FS bit to 1, therefore, there is no need to check for the “E Bit” failure in the FSPR register. Should it set for some reason, it will be swept into the “unknown” category.

Implementation

The Floating Point exception has an offset of 0x070.

Event Driven (FpuErrIrq)

Registers used

RegisterUseRegister Access
SVUM
FPSRThis register is used to control and monitor the cause of floating point exceptionsR/WNo
FPEPCThis register stores the program counter value where the exception occurs.R/WNo

// Get data relating to the fault

TmpData = FPEPC

If (FPSR & 0x0000 4000 != 0) Then

TmpSrc = McuDiagc1.MCUDIAGC_ FPUERRINVLDOPER // Invalid Operation

Else If (FPSR & 0x0000 2000 != 0)

TmpSrc = McuDiagc1.MCUDIAGC_FPUERRDIVBYZERO // Divide by Zero

Elseif (FPSR & 0x0000 1000 != 0)

TmpSrc = McuDiagc1.MCUDIAGC_FPUERROVF // Overflow

Elseif

TmpSrc = McuDiagc1.MCUDIAGC_FPUERRUKWN // Unknown (not expected)

EndIf

NxtrSwRstFromExcpn (TmpSrc, TmpData)

Reference

Verification Method

NA

Sub-Function: Exception Handling Routine Misalignment

Return to sub-function list link: Sub-Functions In This Document

NTCs

None – NTCs are addressed in section 4.29 (Reset Source)

SAN Linkage

SAN-148: When a MPU violation is detected, the access is not granted, but the related information such as access type (read, write), data size, and instruction type are stored in the memory error information register MEI. The memory error address register is used to store the address when a MAE (misaligned) or MPU exception occurs. Both registers can be accessed in the CPU supervisor mode only.

Description

This sub-function handles exceptions generated by a memory misalignment error.

Rationale

TBD

Implementation

The memory misalignment exception has an offset of 0x0C0.

Event Driven (AlgnErrIrq)

Registers used

RegisterUseRegister No. (regID,selID)Register Access
SVUM
MEIMemory error information register – used to indicate if the misalignment was caused during read or writeSR8, 2Yes

No

(via SAN)

MEA

Memory error address register - These bits store an address when a MAE (misaligning) or MPU violation

occurs.

SR6, 2Yes

No

(via SAN)

// Determine source of error and indicate in BRAMDAT0

TmpData = MEA

If (MEI & 0x0000 0001 = 0x0000 00001) Then

TmpSrc = McuDiagc1.MCUDIAGC_ALGNWR

Else

TmpSrc = McuDiagc1.MCUDIAGC_ALGNREAD

End If

NxtrSwRstFromExcpn (TmpSrc, TmpData)

Reference

Verification Method

NA

Sub-Function: Exception Handling Routine Reserved Instruction

Return to sub-function list link: Sub-Functions In This Document

NTCs

N/A

SAN Linkage

None

Description

Rationale

This is basically an exception generated by processing an illegal opcode function.

Implementation

The Reserved Instruction exception has an offset of 0x060.

Event Driven (ResdOperIrq)

Registers used

RegisterUseRegister Access
SVUM
None

// Identify reset cause and reset

NxtrSwRstFromExcpn (McuDiagc1.MCUDIAGC_RESDOPER, 0)

Verification Method

N/A

Sub-Function: Server Routine FENMI PEG

Return to sub-function list link: Sub-Functions In This Document

NTCs

None – NTCs are addressed in section 4.29 (Reset Source)

SAN Linkage

SAN-183: For PE guard violations, a proper error handling shall be performed. For this the ECM shall be configured accordingly.

Description

This server function is called by the MCU handler and is responsible for responding to a PEG (Processor Element Guard) error. The Nexteer design has this configured in the ECM to be an exception of type FENMI. The design notes the source of the error (for later use in the reset cause function), clears the ECM status registers and issues a software reset.

Rationale

FENMI Interrupts are used to represent serious failures within the microcontroller or it’s peripherals that are critical to the overall design. As a result, the Nexteer strategy is to indicate the fault type in backup memory (data retained through a software reset) and force a software reset where the reset type is then indicated and the fault is set (assuming the system can operate to that point).

Note that the function FeNmiPeg is called from the MCU handler.

Implementation

Event Driven (FeNmiPeg)

Registers used

RegisterUseRegister Access
SVUM
None

// Identify reset cause and reset

NxtrSwRstFromExcpn(McuDiagc1.MCUDIAGC_PROCRELMGUARD, 0)

Verification Method

NA

Sub-Function: Server Routine FENMI DMA Transfer Error

Return to sub-function list link: Sub-Functions In This Document

NTCs

None – NTCs are addressed in section 4.29 (Reset Source)

SAN Linkage

SAN-723: When a data parity error is detected, a flag will be set in P-Bus data parity status register APDPERRST_xx (xx stands for the module name) and an internal error signal is propagated towards ECM. In this case the MCU should move to safe state.

SAN-724: If a data parity error has occurred during DMA transfer, a DMA transfer error will be notified.

Description

This server routine is called from the MCU handler and is responsible for responding to DMA transfer errors. The Nexteer design has this configured in the ECM to be an exception of type FENMI. The design notes the source of the error (for later use in the reset cause function), clears the ECM status registers and issues a software reset.

Rationale

N/A

Implementation

Event Driven (FeNmiDmaTrf)

Registers used

RegisterUseRegister Access
SVUM
DMASSDMACERIndicates the status of the two DMAC channelsYesYes

// Indicate data for reset cause (Data0) and information on the responsible DMA channel (Data1)

NxtrSwRstFromExcpn(McuDiagc1.MCUDIAGC_DMATRFERR, DMASSDMACER)

Reference

Verification Method

NA

Sub-Function: Server Routine FENMI DMA Access Violation Error

Return to sub-function list link: Sub-Functions In This Document

NTCs

None – NTCs are addressed in section 4.29 (Reset Source)

SAN Linkage

SAN-100: When the CPU makes an illegal access to the global DMA registers (e.g. access in user mode), then an access violation flag will be set in the related transfer module and an internal error signal will be propagated to the ECM to take the proper action.

Description

This server routine is called from the MCU handler and is responsible for responding to DMA privileged access errors. The Nexteer design has this configured in the ECM to be an exception of type FENMI. The design notes the source of the error (for later use in the reset cause function), clears the ECM status registers and issues a software reset.

Rationale

FENMI Interrupts are used to represent serious failures within the microcontroller or it’s peripherals that are critical to the overall design. As a result, the Nexteer strategy is to indicate the fault type in backup memory (data retained through a software reset) and force a software reset where the reset type is then indicated and the fault is set (assuming the system can operate to that point).

Note that the function ExcpnHndlgFeNmiDMAREGACSPROTECNERR is called from the MCU handler.

In future versions of this document we may want to consider using the registers DM0CMV, DM1CMV and DTSCMV to provide more information when the fault is triggered. Note that these registers require supervisor mode to be accessed – note that the exceptions are already be in SV mode. Initial design will not include them.

Implementation

Event Driven (FeNmiDmaRegAcsProtnErr)

Registers used

RegisterUseRegister Access
SVUM
DMASSDMACERIndicates the status of the two DMAC channelsYesYes

// Indicate data for reset cause (Data0) and information on the responsible DMA channel (Data1)

NxtrSwRstFromExcpn (McuDiagc1.MCUDIAGC_DMAREGACSPROTECNERR, DMASSDMACER)

Reference

Verification Method

NA

Sub-Function: Server Routine FENMI ECM Master/Checker Compare

Return to sub-function list link: Sub-Functions In This Document

NTCs

None – NTCs are addressed in section 4.29 (Reset Source)

SAN Linkage

SAN-656: If there is a mismatch between ECM master and checker an ECM compare error will be set in the ECMmESSTR0/1 register. In that case, the safe state shall be entered.

When the compare unit has detected a comparison mismatch between the DMA Master and Checker, an error signal is propagated to the ECM to take the proper action6.

6 User is required to set up the appropriate error response depending on the application.

Description

This server routine is called from the MCU handler and is responsible for responding errors in which the master and checker compare error. The Nexteer design has this configured in the ECM to be an exception of type FENMI. The design notes the source of the error (for later use in the reset cause function), clears the ECM status registers and issues a software reset.

Rationale

N/A

Implementation

Event Driven (FeNmiEcmMstChkrCmp)

Registers used

RegisterUseRegister Access
SVUM
None

// Identify reset cause and reset

NxtrSwRstFromExcpn (McuDiagc1.MCUDIAGC_ECMMSTCHKRERR, 0)

Verification Method

NA

Sub-Function: Server Routine FENMI Watchdog

NTCs

None – NTCs are addressed in section 4.29 (Reset Source)

SAN Linkage

None

Description

This server routine is called from the MCU handler and is responsible for responding internal watchdog failures. Note that the design is intended to use this server function to also sort to see if the timing failure can be further discriminated to a watchdog, program flow, alive monitor or a deadline monitor failure It is assumed that the MCU will provide the capability to allow Nexteer to select / direct unused features in the design to this routine.

The Nexteer design has configured in the ECM to be an exception of type FENMI without a Reset. The design notes the source of the error (for later use in the reset cause function), clears the ECM status registers and issues a software reset.

Rationale

The SAN recommends a reset when using the ECM for watchdog failures. The Nexteer design will defeat the reset and replace the functionality with a software reset – this is to allow the capability to store parse the fault into watchdog, program flow, alive monitoring and deadline monitoring and provide more information for debug purposes. The ECM configuration as a reset would not allow this to be done.

Note that the function FeNmiWdg is called from the MCU handler.

Implementation

Event Driven (FeNmiWdg)

Registers used

RegisterUseRegister Access
SVUM
EntityStatusGRef (not a register, but key part of this design)This is a structure contained within the AutoSAR module that will provide the means to discriminate different failures that result in a watchdog timeout.NANA

Pseudo Code

TmpSrc = McuDiagc1.MCUDIAGC_FENMIWDG

TmpData = 0

For Each SupervisedEntityID

If (EntityStatusGRef🡪ProgramFlowViolationCnt != 0) Then // Program Flow

TmpSrc = McuDiagc1.MCUDIAGC_FENMIPROGFLOW

TmpData = SupervisedEntityID

End the For Loop

ElseIf (EntityStatusGRef🡪FailedSupervisionRefCycles !=0) // Alive Monitor

TmpSrc = McuDiagc1.MCUDIAGC_FENMIALVMONR

TmpData = SupervisedEntityID

End the For Loop

ElseIf (EntityStatusGRef🡪DeadlineViolationCnt !=0) // Deadline Monitor

TmpSrc = McuDiagc1.MCUDIAGC_FENMIDEADLINEMONR

TmpData = SupervisedEntityID

End the For Loop

Else

End If

End For

// Store data for reset cause use and reset

NxtrSwRstFromExcpn (TmpSrc, TmpData)

Verification Method

NA

Sub-Function: FENMI Clock Monitor 0 RunTime Lower Limit Fault

NTCs

None – NTCs are addressed in section 4.29 (Reset Source)

SAN Linkage

[SAN-P1x-1404]

In case an abnormal operation of the monitored clock is detected, an error signal will be generated to the

ECM. In that case the MCU shall be entered into the safe state.

Description

This server routine is called from the MCU handler and is responsible for responding to Clock Monitor 0 Runtime Lower Limit Failure.

Rationale

FENMI Interrupts are used to represent serious failures within the microcontroller or it’s peripherals that are critical to the overall design. As a result, the Nexteer strategy is to indicate the fault type in backup memory (data retained through a software reset) and force a software reset where the reset type is then indicated and the fault is set (assuming the system can operate to that point).

Note that the function ClkMonr0RtLowrLimFlt is called from the MCU handler.

Implementation

Event Driven (FeNmiClkMonr0RtLowrLimFlt)

Pseudo Code

// Identify reset cause and reset

NxtrSwRstFromExcpn (McuDiagc1.MCUDIAGC_CLKMONR0RTLOWRLIMFLT, 0)

Verification Method

NA

Sub-Function: FENMI Clock Monitor 0 RunTime Upper Limit Fault

NTCs

None – NTCs are addressed in section 4.29 (Reset Source)

SAN Linkage

[SAN-P1x-1404]

In case an abnormal operation of the monitored clock is detected, an error signal will be generated to the

ECM. In that case the MCU shall be entered into the safe state.

Description

This server routine is called from the MCU handler and is responsible for responding to Clock Monitor 0 Runtime Upper Limit Failure.

Rationale

FENMI Interrupts are used to represent serious failures within the microcontroller or it’s peripherals that are critical to the overall design. As a result, the Nexteer strategy is to indicate the fault type in backup memory (data retained through a software reset) and force a software reset where the reset type is then indicated and the fault is set (assuming the system can operate to that point).

Note that the function ClkMonr0RtUpprLimFlt is called from the MCU handler.

Implementation

Event Driven (FeNmiClkMonr0RtUpperLimFlt)

Pseudo Code

// Identify reset cause and reset

NxtrSwRstFromExcpn (McuDiagc1.MCUDIAGC_CLKMONR0RTUPPRLIMFLT, 0)

Verification Method

NA

Sub-Function: FENMI Clock Monitor 1 RunTime Lower Limit Fault

NTCs

None – NTCs are addressed in section 4.29 (Reset Source)

SAN Linkage

[SAN-P1x-1404]

In case an abnormal operation of the monitored clock is detected, an error signal will be generated to the

ECM. In that case the MCU shall be entered into the safe state.

Description

This server routine is called from the MCU handler and is responsible for responding to Clock Monitor 1 Runtime Lower Limit Failure.

Rationale

FENMI Interrupts are used to represent serious failures within the microcontroller or it’s peripherals that are critical to the overall design. As a result, the Nexteer strategy is to indicate the fault type in backup memory (data retained through a software reset) and force a software reset where the reset type is then indicated and the fault is set (assuming the system can operate to that point).

Note that the function ClkMonr1RtLowrLimFlt is called from the MCU handler.

Implementation

Event Driven (FeNmiClkMonr1RtLowrLimFlt)

Pseudo Code

// Identify reset cause and reset

NxtrSwRstFromExcpn (McuDiagc1.MCUDIAGC_CLKMONR1RTLOWRLIMFLT, 0)

Verification Method

NA

Sub-Function: FENMI Clock Monitor 1 RunTime Upper Limit Fault

NTCs

None – NTCs are addressed in section 4.29 (Reset Source)

SAN Linkage

[SAN-P1x-1404]

In case an abnormal operation of the monitored clock is detected, an error signal will be generated to the

ECM. In that case the MCU shall be entered into the safe state.

Description

This server routine is called from the MCU handler and is responsible for responding to Clock Monitor 1 Runtime Upper Limit Failure.

Rationale

FENMI Interrupts are used to represent serious failures within the microcontroller or it’s peripherals that are critical to the overall design. As a result, the Nexteer strategy is to indicate the fault type in backup memory (data retained through a software reset) and force a software reset where the reset type is then indicated and the fault is set (assuming the system can operate to that point).

Note that the function ClkMonr1RtUpperLimFlt is called from the MCU handler.

Implementation

Event Driven (FeNmiClkMonr1RtUpperLimFlt)

Pseudo Code

// Identify reset cause and reset

NxtrSwRstFromExcpn (McuDiagc1.MCUDIAGC_CLKMONR1RTUPPRLIMFLT, 0)

Verification Method

NA

Sub-Function: FENMI Clock Monitor 2 RunTime Lower Limit Fault

NTCs

None – NTCs are addressed in section 4.29 (Reset Source)

SAN Linkage

[SAN-P1x-1404]

In case an abnormal operation of the monitored clock is detected, an error signal will be generated to the

ECM. In that case the MCU shall be entered into the safe state.

Description

This server routine is called from the MCU handler and is responsible for responding to Clock Monitor 2 Runtime Lower Limit Failure.

Rationale

FENMI Interrupts are used to represent serious failures within the microcontroller or it’s peripherals that are critical to the overall design. As a result, the Nexteer strategy is to indicate the fault type in backup memory (data retained through a software reset) and force a software reset where the reset type is then indicated and the fault is set (assuming the system can operate to that point).

Note that the function ClkMonr2RtLowrLimFlt is called from the MCU handler.

Implementation

Event Driven (FeNmiClkMonr2RtLowrLimFlt)

Pseudo Code

// Identify reset cause and reset

NxtrSwRstFromExcpn (McuDiagc1.MCUDIAGC_CLKMONR2RTLOWRLIMFLT, 0)

Verification Method

NA

Sub-Function: FENMI Clock Monitor 2 RunTime Upper Limit Fault

NTCs

None – NTCs are addressed in section 4.29 (Reset Source)

SAN Linkage

[SAN-P1x-1404]

In case an abnormal operation of the monitored clock is detected, an error signal will be generated to the

ECM. In that case the MCU shall be entered into the safe state.

Description

This server routine is called from the MCU handler and is responsible for responding to Clock Monitor 2 Runtime Upper Limit Failure.

Rationale

FENMI Interrupts are used to represent serious failures within the microcontroller or it’s peripherals that are critical to the overall design. As a result, the Nexteer strategy is to indicate the fault type in backup memory (data retained through a software reset) and force a software reset where the reset type is then indicated and the fault is set (assuming the system can operate to that point).

Note that the function ClkMonr2RtUpperLimFlt is called from the MCU handler.

Implementation

Event Driven (FeNmiClkMonr2RtUpperLimFlt)

Pseudo Code

// Identify reset cause and reset

NxtrSwRstFromExcpn (McuDiagc1.MCUDIAGC_CLKMONR2RTUPPRLIMFLT, 0)

Verification Method

NA

Sub-Function: FENMI Clock Monitor 3 RunTime Lower Limit Fault

NTCs

None – NTCs are addressed in section 4.29 (Reset Source)

SAN Linkage

[SAN-P1x-1404]

In case an abnormal operation of the monitored clock is detected, an error signal will be generated to the

ECM. In that case the MCU shall be entered into the safe state.

Description

This server routine is called from the MCU handler and is responsible for responding to Clock Monitor 3 Runtime Lower Limit Failure.

Rationale

FENMI Interrupts are used to represent serious failures within the microcontroller or it’s peripherals that are critical to the overall design. As a result, the Nexteer strategy is to indicate the fault type in backup memory (data retained through a software reset) and force a software reset where the reset type is then indicated and the fault is set (assuming the system can operate to that point).

Note that the function ClkMonr3RtLowrLimFlt is called from the MCU handler.

Implementation

Event Driven (FeNmiClkMonr3RtLowrLimFlt)

Pseudo Code

// Identify reset cause and reset

NxtrSwRstFromExcpn (McuDiagc1.MCUDIAGC_CLKMONR3RTLOWRLIMFLT, 0)

Verification Method

NA

Sub-Function: FENMI Clock Monitor 3 RunTime Upper Limit Fault

NTCs

None – NTCs are addressed in section 4.29 (Reset Source)

SAN Linkage

[SAN-P1x-1404]

In case an abnormal operation of the monitored clock is detected, an error signal will be generated to the

ECM. In that case the MCU shall be entered into the safe state.

Description

This server routine is called from the MCU handler and is responsible for responding to Clock Monitor 3 Runtime Upper Limit Failure.

Rationale

FENMI Interrupts are used to represent serious failures within the microcontroller or it’s peripherals that are critical to the overall design. As a result, the Nexteer strategy is to indicate the fault type in backup memory (data retained through a software reset) and force a software reset where the reset type is then indicated and the fault is set (assuming the system can operate to that point).

Note that the function ClkMonr3RtUpperLimFlt is called from the MCU handler.

Implementation

Event Driven (FeNmiClkMonr3RtUpperLimFlt)

Pseudo Code

// Identify reset cause and reset

NxtrSwRstFromExcpn (McuDiagc1.MCUDIAGC_CLKMONR3RTUPPRLIMFLT, 0)

Verification Method

NA

Sub Function: FENMI Operating Mode Error Single Chip Mode Inactive

NTCs

None – NTCs are addressed in section 4.29 (Reset Source)

SAN Linkage

[SAN-P1x-2503]

Unintended mode activation during run-time is notified to the ECM via a dedicated error signal. When the current operation mode is “Single Chip mode” and the internal signal which indicates Flash programming mode becomes valid, an internal error signal is propagated to the ECM becomes active (high). Similarly, when the internal signal which indicates that “Single Chip Mode” is deactivate, internal error signals are propagated to the ECM. In that case, transition to the safe state shall be performed [SAN-P1x-2503].

Description

This server routine is called from the MCU handler and is responsible for responding to Mode error (single-chip mode is inactive in single-chip mode)

Rationale

FENMI Interrupts are used to represent serious failures within the microcontroller or it’s peripherals that are critical to the overall design. As a result, the Nexteer strategy is to indicate the fault type in backup memory (data retained through a software reset) and force a software reset where the reset type is then indicated and the fault is set (assuming the system can operate to that point).

Implementation

Event Driven (FeNmiOperModErrSngChipInactv)

// Perform software reset from exception and pass appropriate arguments

NxtrSwRstFromExcpn(MCUDIAGC_OPERMODERRSNGCHIPINACTV, 0)

Verification Method

NA

Sub Function: FENMI Operating Mode Error Flash Programming Mode is Started in Single-Chip Mode

NTCs

None – NTCs are addressed in section 4.29 (Reset Source)

SAN Linkage

[SAN-P1x-2503]

Unintended mode activation during run-time is notified to the ECM via a dedicated error signal. When the current operation mode is “Single Chip mode” and the internal signal which indicates Flash programming mode becomes valid, an internal error signal is propagated to the ECM becomes active (high). Similarly, when the internal signal which indicates that “Single Chip Mode” is deactivate, internal error signals are propagated to the ECM. In that case, transition to the safe state shall be performed [SAN-P1x-2503].

Description

This server routine is called from the MCU handler and is responsible for responding to Mode error (flash programming mode is started in single-chip mode)

Rationale

FENMI Interrupts are used to represent serious failures within the microcontroller or it’s peripherals that are critical to the overall design. As a result, the Nexteer strategy is to indicate the fault type in backup memory (data retained through a software reset) and force a software reset where the reset type is then indicated and the fault is set (assuming the system can operate to that point).

Implementation

Event Driven (FeNmiOperModErrFlsProgmModStrtd)

// Perform software reset from exception and pass appropriate arguments

NxtrSwRstFromExcpn(MCUDIAGC_OPERMODERRFLSPROGMMODSTRTD, 0)

Verification Method

NA

Sub Function: FENMI Operating Mode Error Test Mode Started in Single Chip Mode

NTCs

None – NTCs are addressed in section 4.29 (Reset Source)

SAN Linkage

[SAN-P1x-2503]

Unintended mode activation during run-time is notified to the ECM via a dedicated error signal. When the current operation mode is “Single Chip mode” and the internal signal which indicates Flash programming mode becomes valid, an internal error signal is propagated to the ECM becomes active (high). Similarly, when the internal signal which indicates that “Single Chip Mode” is deactivate, internal error signals are propagated to the ECM. In that case, transition to the safe state shall be performed [SAN-P1x-2503].

Description

This server routine is called from the MCU handler and is responsible for responding to Mode error (test mode is started in single-chip mode)

Rationale

FENMI Interrupts are used to represent serious failures within the microcontroller or it’s peripherals that are critical to the overall design. As a result, the Nexteer strategy is to indicate the fault type in backup memory (data retained through a software reset) and force a software reset where the reset type is then indicated and the fault is set (assuming the system can operate to that point).

Implementation

Event Driven (FeNmiOperModErrTestModStrtd)

// Perform software reset from exception and pass appropriate arguments

NxtrSwRstFromExcpn(MCUDIAGC_OPERMODERRTESTMODSTRTD, 0)

Verification Method

NA

Sub Function: Server Routine Process Unknown Exception Error

NTCs

None – NTCs are addressed in section 4.29 (Reset Source)

SAN Linkage

None

Description

The Process Unknown Exception Error needs to be called when the OS detects an unknown exception.

Rationale

Implementation

Event Driven (ProcUkwnExcpnErr)

// Perform software reset from exception and pass appropriate arguments

NxtrSwRstFromExcpn(MCUDIAGC_UKWNEXCPN, McuDiagcData1_Arg)

Verification Method

NA

Sub-Function: Server Routine Process Memory Protection Unit Exception Error

NTCs

None – NTCs are addressed in section 4.29 (Reset Source)

SAN Linkage

None

Description

The Process Memory Protection Unit Exception Error needs to be called when the OS detects a memory protection violation.

Rationale

Implementation

Event Driven (ProcMpuExcpnErr)

// Perform software reset from exception and pass appropriate arguments

NxtrSwRstFromExcpn(MCUDIAGC_MPU, McuDiagcData1_Arg)

Verification Method

NA

Sub-Function: Server Routine Process Privileged Instruction Exception Error

NTCs

None – NTCs are addressed in section 4.29 (Reset Source)

SAN Linkage

None

Description

The Process Privileged Instruction Exception Error needs to be called when the OS detects a protection violation.

Rationale

Implementation

Event Driven (ProcPrvlgdInstrExcpnErr)

// Perform software reset from exception and pass appropriate arguments

NxtrSwRstFromExcpn(MCUDIAGC_PRVLGDINSTREXCPN, McuDiagcData1_Arg)

Verification Method

NA

Sub-Function: Server Routine Process Permanent Os Error

NTCs

None – NTCs are addressed in section 4.29 (Reset Source)

SAN Linkage

None

Description

The Process Permanent Os Error needs to be called when the OS detects a fatal, permanent failure.

Rationale

Implementation

Event Driven (ProcPrmntOsErr)

// Perform software reset from exception and pass appropriate arguments

NxtrSwRstFromExcpn(MCUDIAGC_PRMNTOSERR, McuDiagcData1_Arg)

Verification Method

NA

Sub-Function: Server Routine Process Non Critical Os Error

NTCs

None – NTCs are addressed in section 4.29 (Reset Source)

SAN Linkage

None

Description

The Process Non Critical Os Error needs to be called when the OS detects a non-fatal failure.

Rationale

Implementation

Event Driven (ProcNonCritOsErr)

// Update error code variable that is polled in periodic function

ExcpnHndlgOsErrCod_C = McuDiagcData1_Arg

Verification Method

NA

Periodic (ExcpnHndlgPer1)

** NOTE: variable ExcpnHndlgOsErrCod must reside in global shared memory **

If (ExcpnHndlgOsErrCod != 0x0000) then

// Set code for non-fatal OS error – Error Code is on the data ExcpnHndlgOsErrCod

SetNtcSts(NtcNr1.NTCNR_0x031, 1, NtcSts1.NTCSTS_FAILD, 0)

End If

Verification Method

NA

Sub-Function: Server Routine Shutdown Hook

Call EcuM_Shutdown()

Sub-Function: Exception Handling Routine EIINT

Return to sub-function list link: Sub-Functions In This Document

It is assumed that the MCU configuration will directly provide a client/server call to the necessary FDDs to accomplish their tasks. It would be redundant to place them within this document only to call out another document, so this is the chosen approach.

Please refer to other microcontroller diagnostic FDDs to see their specific exception handler functionality.

Sub-Function: Reset Source Determination

Return to sub-function list link: Sub-Functions In This Document

NTCs

003.0 Code Flash ECC Single Bit (Hard Fault)

003.1 Code Flash ECC Double Bit Detection

003.2 Code Flash ECC Address Parity Fault

010.0 MBIST Startup Test Failure

013.0 Local RAM ECC Single Bit (Hard Fault)

013.1 Local RAM ECC Double Bit (Hard Fault)

013.2 Local RAM Address Fault

016.1 DTS ECC Double Bit (Hard Fault)

021.0 BIST Code ECC Failure

021.2 LBIST Startup Test Failure

021.4 BIST Not Complete

021.5 CPU Lock Step Error Forcing Startup Test Failure

021.6 DMA Lock Step Error Forcing Startup Test Failure

022.0 Lock Step Compare Fault

022.1 System VCIE Bit Error

022.2 Reserved Instruction (Illegal Op Code) Fault

022.3 Memory Misalignment - Read

022.4 Memory Misalignment - Write

022.5 Instruction Fetch Error

022.6 FACI Reset Transfer Error

023.2 CLMA 0 Runtime Lower Limit Fault

023.3 CLMA 0 Runtime Upper Limit Fault

023.6 CLMA 2 Runtime Lower Limit Fault

023.7 CLMA 2 Runtime Upper Limit Fault

024.0 Mode Error (Flash Programming Mode is Started in Single-Chip Mode)

024.1 Mode Error (Test Mode Started in Single Chip Mode)

024.2 Mode Error (Single Chip Mode Inactive in Single Chip Mode)

025.0 MPU Violation (this convers MDP and MIP Exception)

025.1 Privilege Instruction Execution

026.0 ECM Status Bit Set Prior to ECM Init

026.2 ECM Startup Master nERROR Output Control Fault

026.3 ECM Startup Checker nERROR Output Control Fault

026.7 ECM Runtime Master-Checker Compare Fault027

027.2 CLMA 1 Runtime Lower Limit Fault

027.3 CLMA 1 Runtime Upper Limit Fault

027.6 CLMA 3 Runtime Lower Limit Fault

027.7 CLMA 3 Runtime Upper Limit Fault

028.1 FPU Invalid Operation (V Bit)

028.2 FPU Divide by Zero (Z Bit)

028.3 FPUOverflow (O Bit)

028.4 FPU Unknown Error

029.0 Unknown Reset Reason

029.1 Unknown ECM Reset Reason

029.4 Unknown Software Reset

029.5 Failed Backup RAM Read Write Test

029.6 FBL Pre-OS Startup Exception

029.7 Corrupt Start up / Reset Information

02A.0 Program Flow

02A.1 Deadline Monitoring

02A.2 Alive Monitoring

02C.0 Watchdog Timeout

02D.1 PEG Runtime Fault

02D.3 IPG RunTime Fault

02D.4 PBG (Peripheral Guard) Startup Test Failure

02D.5 PBG Runtime Fault

02F.0 External Debug Device Connected

030.0 Operating System Fatal Fault

030.1 Unhandled Exception

031.0 Operating System Non-Fatal Fault

036.0 DMA Transfer Error

036.1 DMA Register Access Protection Violation

037.6 P-Bus Data Parity Fault Startup Test Failure

037.7 P Bus Data Parity Runtime Fault

048.0 CVM Over Voltage Startup Test Failure

048.1 CVM Under Voltage Startup Test Failure

049.0 Internal CVM Over Voltage Monitor Fault

049.1 Internal CVM Under Voltage Monitor Fault

049.7 External Over Voltage Monitor Fault

SAN Linkage

SAN-621: Upon detection of under/overvoltage of the core power supply, the signal at the CVMOUT pin changes its state to low and a dedicated flag will be set in the CVMF register. It is also possible to generate a reset if the software has enabled it. In that case, transition the MCU into the safe state shall be entered.

SAN-1024: As the usage of backup registers is strongly application dependents, the user should judge whether or not to apply the proposed write verify check. Moreover, if the data retained in the back-up register will be frequently used in the safety related application, then the contain should be moved to LRAM as it is protected by ECC and thus provide a high fault coverage.

SAN-1094: As the usage of backup registers is strongly application dependents, the user should judge whether or not to apply the proposed write verify check. Moreover, if the data retained in the back-up register will be frequently used in the safety related application, then the contain should be moved to LRAM as it is protected by ECC and thus provide a high fault coverage.

SAN-1096: Detected failures during the execution of the test shall be handled at application level.

Description

This function processes information from pre-OS tests and resets to determine the cause of anything unexpected and log the correct Nexteer Trouble Code. Backup RAM data is used to provide this information to the function.

Rationale

In order to log Nexteer Trouble Code information, the Diagnostic Manager must be initialized prior to setting or clearing NTCs.

Implementation

Initialization (ExcpnHndlgInit2)

SetNtcSts(NtcNr1.NTCNR_0x003, 0, NtcSts1.NTCSTS_PASSD, 0)

SetNtcSts(NtcNr1.NTCNR_0x010, 0, NtcSts1.NTCSTS_PASSD, 0)

SetNtcSts(NtcNr1.NTCNR_0x013, 0, NtcSts1.NTCSTS_PASSD, 0)

SetNtcSts(NtcNr1.NTCNR_0x016, 0, NtcSts1.NTCSTS_PASSD, 0)

SetNtcSts(NtcNr1.NTCNR_0x021, 0, NtcSts1.NTCSTS_PASSD, 0)

SetNtcSts(NtcNr1.NTCNR_0x022, 0, NtcSts1.NTCSTS_PASSD, 0)

SetNtcSts(NtcNr1.NTCNR_0x023, 0, NtcSts1.NTCSTS_PASSD, 0)

SetNtcSts(NtcNr1.NTCNR_0x024, 0, NtcSts1.NTCSTS_PASSD, 0)

SetNtcSts(NtcNr1.NTCNR_0x025, 0, NtcSts1.NTCSTS_PASSD, 0)

SetNtcSts(NtcNr1.NTCNR_0x026, 0, NtcSts1.NTCSTS_PASSD, 0)

SetNtcSts(NtcNr1.NTCNR_0x027, 0, NtcSts1.NTCSTS_PASSD, 0)

SetNtcSts(NtcNr1.NTCNR_0x028, 0, NtcSts1.NTCSTS_PASSD, 0)

SetNtcSts(NtcNr1.NTCNR_0x029, 0, NtcSts1.NTCSTS_PASSD, 0)

SetNtcSts(NtcNr1.NTCNR_0x02A, 0, NtcSts1.NTCSTS_PASSD, 0)

SetNtcSts(NtcNr1.NTCNR_0x02C, 0, NtcSts1.NTCSTS_PASSD, 0)

SetNtcSts(NtcNr1.NTCNR_0x02D, 0, NtcSts1.NTCSTS_PASSD, 0)

SetNtcSts(NtcNr1.NTCNR_0x02F, 0, NtcSts1.NTCSTS_PASSD, 0)

SetNtcSts(NtcNr1.NTCNR_0x030, 0, NtcSts1.NTCSTS_PASSD, 0)

SetNtcSts(NtcNr1.NTCNR_0x031, 0, NtcSts1.NTCSTS_PASSD, 0)

SetNtcSts(NtcNr1.NTCNR_0x036, 0, NtcSts1.NTCSTS_PASSD, 0)

SetNtcSts(NtcNr1.NTCNR_0x037, 0, NtcSts1.NTCSTS_PASSD, 0)

SetNtcSts(NtcNr1.NTCNR_0x048, 0, NtcSts1.NTCSTS_PASSD, 0)

SetNtcSts(NtcNr1.NTCNR_0x049, 0, NtcSts1.NTCSTS_PASSD, 0)

// Confirm state of backup data is valid

If (((BRAMDAT0 & 0xFFFF 0000) >> 16) XOR (BRAMDAT0 & 0x0000 FFFF)) != 0x0000 FFFF) Then

// Set fault – BRAMDAT0 data is corrupt and cannot be trusted

SetNtcSts(NtcNr1.NTCNR_0x029, 128, NtcSts1.NTCSTS_FAILD, 0)

Else If ((BRAMDAT0 = McuDiagc1.MCUDIAGC_PWRONRST) OR (BRAMDAT0 = McuDiagc1.MCUDIAGC_FLSPROGMCMPL) OR (BRAMDAT0 = McuDiagc1.MCUDIAGC_HARDRST) OR (BRAMDAT0 = McuDiagc1.MCUDIAGC_SOFTRST)) Then

// No checks needed – normal power on start up or flash programming event or soft/hard reset

Else If ((SYSBSEQ0ST.DEBUGMODE = 1) AND (SYSBSEQ0STB. DEBUGMODEB = 0))

// No checks needed in debug mode

Else If (BRAMDAT0 = McuDiagc1.MCUDIAGC_ECMRST)

ProcEcmRst() // Reset from ECM

ElseIf (BRAMDAT0 = McuDiagc1.MCUDIAGC_PINRST)

ProcPinRst() // Reset from External Pin (Power Supply)

ElseIf (BRAMDAT0 = McuDiagc1.MCUDIAGC_COREVLTGMONRHI) // Overvoltage internal to uC

SetNtcSts(NtcNr1.NTCNR_0x049, 1, NtcSts1.NTCSTS_FAILD, 0)

ElseIf (BRAMDAT0 = McuDiagc1.MCUDIAGC_COREVLTGMONRLO) // Low voltage internal to uC

SetNtcSts(NtcNr1.NTCNR_0x049, 2, NtcSts1.NTCSTS_FAILD, 0)

Else

ProcStrtUpOrSwRst() // Check for start-up, non-reset faults

End If

FunctionCall ProcEcmRst

//Check for lock step fault in either core

// By design, lock step is the only ECM fault resulting in a reset - confirm

If ((ECMMSSE001 = 1) or (ECMCSSE001 = 1)) Then

// Set lock step fault

SetNtcSts(NtcNr1.NTCNR_0x022, 1, NtcSts1.NTCSTS_FAILD, 0)

Else

// Set unknown ECM reset fault

SetNtcSts(NtcNr1.NTCNR_0x029, 2, NtcSts1.NTCSTS_FAILD, 0)

End If

// Clear all the bits of ECMmESSTR0

ECMESSTC0_Desired = 0xFDFF DFF3;

WrProtdRegEcm_u32 (ECMESSTC0_Desired, Address of ECMESSTC0);

// Clear all the bits of ECMmESSTR1

ECMESSTC1_Desired = 0x6000 07F7;

WrProtdRegEcm_u32 (ECMESSTC1_Desired, Address of ECMESSTC1);

FunctionCall ProcStrtUpOrSwRst

Switch: BRAMDAT0

// Pre-OS failures, (non-sw reset)

Case: McuDiagc1.MCUDIAGC_MEMBISTERR

SetNtcSts(NtcNr1.NTCNR_0x010, 1, NtcSts1.NTCSTS_FAILD, 0) // MBIST Proof

Break

Case: McuDiagc1.MCUDIAGC_BISTECCERR

SetNtcSts(NtcNr1.NTCNR_0x021, 1, NtcSts1.NTCSTS_FAILD, 0) //BIST 2 bit ECC

Break

Case: McuDiagc1.MCUDIAGC_LOGLBISTERR

SetNtcSts(NtcNr1.NTCNR_0x021, 4, NtcSts1.NTCSTS_FAILD, 0) //LBIST Proof

Break

Case: McuDiagc1.MCUDIAGC_BISTNOTCMPLERR

SetNtcSts(NtcNr1.NTCNR_0x021, 16, NtcSts1.NTCSTS_FAILD, 0) //BIST not complete

Break

Case: McuDiagc1.MCUDIAGC_CPULOCKSTEPERR

SetNtcSts(NtcNr1.NTCNR_0x021, 32, NtcSts1.NTCSTS_FAILD, 0) //CPU Lock Step Proof

Break

Case: McuDiagc1.MCUDIAGC_DMALOCKSTEPERR

SetNtcSts(NtcNr1.NTCNR_0x021, 64, NtcSts1.NTCSTS_FAILD, 0) //DMA Lock Step Proof

Break

Case: McuDiagc1. MCUDIAGC_ECMSTSSTRTUPFLT

SetNtcSts(NtcNr1.NTCNR_0x026, 1, NtcSts1.NTCSTS_FAILD, 0) // ECM Status Prob

Break

Case: McuDiagc1.MCUDIAGC_MSTERROUTPCTRLFLT

SetNtcSts(NtcNr1.NTCNR_0x026, 4, NtcSts1.NTCSTS_FAILD, 0) //Master Control Proof

Break

Case: McuDiagc1.MCUDIAGC_CHKRERROUTPCTRLFLT

SetNtcSts(NtcNr1.NTCNR_0x026, 8, NtcSts1.NTCSTS_FAILD, 0) //Checker Control Proof

Break

Case: McuDiagc1. MCUDIAGC_BACKUPRAMTSTFAILR

SetNtcSts(NtcNr1.NTCNR_0x029, 32, NtcSts1.NTCSTS_FAILD, 0) //Back-Up Test Fail

Break

Case: McuDiagc1.MCUDIAGC_PREOSEXCPN

SetNtcSts(NtcNr1.NTCNR_0x029, 64, NtcSts1.NTCSTS_FAILD, 0) //Pre-OS Exception

Break

Case: McuDiagc1.MCUDIAGC_STRTUPCOREVLTGMONROVER

SetNtcSts(NtcNr1.NTCNR_0x048, 1, NtcSts1.NTCSTS_FAILD, 0) //CVM OV Proof

Break

Case: McuDiagc1.MCUDIAGC_STRTUPCOREVLTGMONRUNDER

SetNtcSts(NtcNr1.NTCNR_0x048, 2, NtcSts1.NTCSTS_FAILD, 0) //CVM UV Proof

Break

Case: McuDiagc1.MCUDIAGC_PBGSTRTUPTST

SetNtcSts(NtcNr1.NTCNR_0x02D, 16, NtcSts1.NTCSTS_FAILD, 0) //PBG (Peripheral Guard) Startup Test Failure

Break

Case: McuDiagc1.MCUDIAGC_PRPHLBUSDATAPARSTRTUPFLT

SetNtcSts(NtcNr1.NTCNR_0x037, 64, NtcSts1.NTCSTS_FAILD, 0) // P-Bus Data Parity Fault Startup Test Failure

Break

Case: McuDiagc1.MCUDIAGC_RSTUKWN

SetNtcSts(NtcNr1.NTCNR_0x029, 1, NtcSts1.NTCSTS_FAILD, 0) // Unknown Rst to FBL

Break

// Software Resets

Case: McuDiagc1.MCUDIAGC_DBGRST

SetNtcSts(NtcNr1.NTCNR_0x02F, 1, NtcSts1.NTCSTS_FAILD, 0)

Break

Case: McuDiagc1.MCUDIAGC_CODFLSSNGBITHARDFLT

SetNtcSts(NtcNr1.NTCNR_0x003, 1, NtcSts1.NTCSTS_FAILD, 0)

Break

Case: McuDiagc1.MCUDIAGC_CODFLSDBLBIT

SetNtcSts(NtcNr1.NTCNR_0x003, 2, NtcSts1.NTCSTS_FAILD, 0)

Break

Case: MCUDIAGC_PRPHLBUSDATAPAR

SetNtcSts(NtcNr1.NTCNR_0x037, 128, NtcSts1.NTCSTS_FAILD, 0)

Break

Case: McuDiagc1.MCUDIAGC_ADRPAR

SetNtcSts(NtcNr1.NTCNR_0x003, 4, NtcSts1.NTCSTS_FAILD, 0)

Break

Case: McuDiagc1. MCUDIAGC_LCLRAMECCSNGBITHARDFAILR

SetNtcSts(NtcNr1.NTCNR_0x013, 1, NtcSts1.NTCSTS_FAILD, 0)

Break

Case: McuDiagc1.MCUDIAGC_LCLRAMDBLBIT

SetNtcSts(NtcNr1.NTCNR_0x013, 2, NtcSts1.NTCSTS_FAILD, 0)

Break

Case: McuDiagc1.MCUDIAGC_INVLDRAMAREA

SetNtcSts(NtcNr1.NTCNR_0x013, 4, NtcSts1.NTCSTS_FAILD, 0)

Break

Case: McuDiagc1.MCUDIAGC_DTSDBLBIT

SetNtcSts(NtcNr1.NTCNR_0x016, 2, NtcSts1.NTCSTS_FAILD, 0)

Break

Case: McuDiagc1.MCUDIAGC_SPIRAMDBLBIT0

SetNtcSts(NtcNr1.NTCNR_0x017, 2, NtcSts1.NTCSTS_FAILD, 0)

Break

Case: McuDiagc1.MCUDIAGC_SPIRAMDBLBIT1

SetNtcSts(NtcNr1.NTCNR_0x018, 2, NtcSts1.NTCSTS_FAILD, 0)

Break

Case: McuDiagc1.MCUDIAGC_SPIRAMDBLBIT2

SetNtcSts(NtcNr1.NTCNR_0x019, 2, NtcSts1.NTCSTS_FAILD, 0)

Break

Case: McuDiagc1.MCUDIAGC_SPIRAMDBLBIT3

SetNtcSts(NtcNr1.NTCNR_0x01A, 2, NtcSts1.NTCSTS_FAILD, 0)

Break

Case: McuDiagc1.MCUDIAGC_VCIE

SetNtcSts(NtcNr1.NTCNR_0x022, 2, NtcSts1.NTCSTS_FAILD, 0)

Break

Case: McuDiagc1.MCUDIAGC_RESDOPER

SetNtcSts(NtcNr1.NTCNR_0x022, 4, NtcSts1.NTCSTS_FAILD, 0)

Break

Case: McuDiagc1.MCUDIAGC_ALGNREAD

SetNtcSts(NtcNr1.NTCNR_0x022, 8, NtcSts1.NTCSTS_FAILD, 0)

Break

Case: McuDiagc1.MCUDIAGC_ALGNWR

SetNtcSts(NtcNr1.NTCNR_0x022, 16, NtcSts1.NTCSTS_FAILD, 0)

Break

Case: McuDiagc1.MCUDIAGC_INSTRFETCH

SetNtcSts(NtcNr1.NTCNR_0x022, 32, NtcSts1.NTCSTS_FAILD, 0)

Break

Case: McuDiagc1.MCUDIAGC_FACIRSTTRFERR

SetNtcSts(NtcNr1.NTCNR_0x022, 64, NtcSts1.NTCSTS_FAILD, 0)

Break

Case: McuDiagc1.MCUDIAGC_OPERMODERRFLSPROGMMODSTRTD

SetNtcSts(NtcNr1.NTCNR_0x024, 1, NtcSts1.NTCSTS_FAILD, 0)

Break

Case: McuDiagc1.MCUDIAGC_OPERMODERRTESTMODSTRTD

SetNtcSts(NtcNr1.NTCNR_0x024, 2, NtcSts1.NTCSTS_FAILD, 0)

Break

Case: McuDiagc1.MCUDIAGC_OPERMODERRSNGCHIPINACTV

SetNtcSts(NtcNr1.NTCNR_0x024, 4, NtcSts1.NTCSTS_FAILD, 0)

Break

Case: McuDiagc1.MCUDIAGC_ MPU

SetNtcSts(NtcNr1.NTCNR_0x025, 1, NtcSts1.NTCSTS_FAILD, 0)

Break

Case: McuDiagc1.MCUDIAGC_ PRVLGDINSTREXCPN

SetNtcSts(NtcNr1.NTCNR_0x025, 2, NtcSts1.NTCSTS_FAILD, 0)

Break

Case: McuDiagc1.MCUDIAGC_ ECMMSTCHKRERR

SetNtcSts(NtcNr1.NTCNR_0x026, 128, NtcSts1.NTCSTS_FAILD, 0)

Break

Case: McuDiagc1.MCUDIAGC_FPUERRINVLDOPER

SetNtcSts(NtcNr1.NTCNR_0x028, 2, NtcSts1.NTCSTS_FAILD, 0)

Break

Case: McuDiagc1.MCUDIAGC_FPUERRDIVBYZERO

SetNtcSts(NtcNr1.NTCNR_0x028, 4, NtcSts1.NTCSTS_FAILD, 0)

Break

Case: McuDiagc1.MCUDIAGC_FPUERROVF

SetNtcSts(NtcNr1.NTCNR_0x028, 8, NtcSts1.NTCSTS_FAILD, 0)

Break

Case: McuDiagc1.MCUDIAGC_FPUERRUKWN

SetNtcSts(NtcNr1.NTCNR_0x028, 16, NtcSts1.NTCSTS_FAILD, 0)

Break

Case: McuDiagc1.MCUDIAGC_FENMIPROGFLOW

SetNtcSts(NtcNr1.NTCNR_0x02A, 1, NtcSts1.NTCSTS_FAILD, 0)

Break

Case: McuDiagc1.MCUDIAGC_FENMIDEADLINEMONR

SetNtcSts(NtcNr1.NTCNR_0x02A, 2, NtcSts1.NTCSTS_FAILD, 0)

Break

Case: McuDiagc1.MCUDIAGC_FENMIALVMONR

SetNtcSts(NtcNr1.NTCNR_0x02A, 4, NtcSts1.NTCSTS_FAILD, 0)

Break

Case: McuDiagc1.MCUDIAGC_FENMIWDG

SetNtcSts(NtcNr1.NTCNR_0x02C, 1, NtcSts1.NTCSTS_FAILD, 0)

Break

Case: McuDiagc1.MCUDIAGC_CLKMONR0RTLOWRLIMFLT

SetNtcSts(NtcNr1.NTCNR_0x023, 4, NtcSts1.NTCSTS_FAILD, 0)

Break

Case: McuDiagc1.MCUDIAGC_CLKMONR0RTUPPRLIMFLT

SetNtcSts(NtcNr1.NTCNR_0x023, 8, NtcSts1.NTCSTS_FAILD, 0)

Break

Case: McuDiagc1.MCUDIAGC_CLKMONR1RTLOWRLIMFLT

SetNtcSts(NtcNr1.NTCNR_0x027, 4, NtcSts1.NTCSTS_FAILD, 0)

Break

Case: McuDiagc1.MCUDIAGC_CLKMONR1RTUPPRLIMFLT

SetNtcSts(NtcNr1.NTCNR_0x027, 8, NtcSts1.NTCSTS_FAILD, 0)

Break

Case: McuDiagc1.MCUDIAGC_CLKMONR2RTLOWRLIMFLT

SetNtcSts(NtcNr1.NTCNR_0x023, 64, NtcSts1.NTCSTS_FAILD, 0)

Break

Case: McuDiagc1.MCUDIAGC_CLKMONR2RTUPPRLIMFLT

SetNtcSts(NtcNr1.NTCNR_0x023, 128, NtcSts1.NTCSTS_FAILD, 0)

Break

Case: McuDiagc1.MCUDIAGC_CLKMONR3RTLOWRLIMFLT

SetNtcSts(NtcNr1.NTCNR_0x027, 64, NtcSts1.NTCSTS_FAILD, 0)

Break

Case: McuDiagc1.MCUDIAGC_CLKMONR3RTUPPRLIMFLT

SetNtcSts(NtcNr1.NTCNR_0x027, 128, NtcSts1.NTCSTS_FAILD, 0)

Break

Case: McuDiagc1.MCUDIAGC_PROCRELMGUARD

SetNtcSts(NtcNr1.NTCNR_0x02D, 2, NtcSts1.NTCSTS_FAILD, 0)

Break

Case: McuDiagc1.MCUDIAGC_INTPRPHLGUARD

SetNtcSts(NtcNr1.NTCNR_0x02D, 8, NtcSts1.NTCSTS_FAILD, 0)

Break

Case: McuDiagc1.MCUDIAGC_PRPHLBUSGUARD

SetNtcSts(NtcNr1.NTCNR_0x02D, 32, NtcSts1.NTCSTS_FAILD, 0)

Break

Case: McuDiagc1.MCUDIAGC_PRMNTOSERR

SetNtcSts(NtcNr1.NTCNR_0x030, 1, NtcSts1.NTCSTS_FAILD, 0)

Break

Case: McuDiagc1.MCUDIAGC_UKWNEXCPN

SetNtcSts(NtcNr1.NTCNR_0x030, 2, NtcSts1.NTCSTS_FAILD, 0)

Break

Case: McuDiagc1.MCUDIAGC_DMATRFERR

SetNtcSts(NtcNr1.NTCNR_0x036, 1, NtcSts1.NTCSTS_FAILD, 0)

Break

Case: McuDiagc1.MCUDIAGC_DMAREGACSPROTECNERR

SetNtcSts(NtcNr1.NTCNR_0x036, 2, NtcSts1.NTCSTS_FAILD, 0)

Break

Default:

SetNtcSts(NtcNr1.NTCNR_0x029, 16, NtcSts1.NTCSTS_FAILD, 0) // unknown SW Reset

Break

End Switch

FunctionCall ProcPinRst

SetNtcSts(NtcNr1.NTCNR_0x049, 128, NtcSts1.NTCSTS_FAILD, 0) // External Pin Reset

Verification Method

NA

Special Functions

For this design, some special functions are used to identify the first failure of data and respond. Once data is changed from its known, good states (power on reset or flash programming complete) the BRAMDAT0 will not be updated until a valid power up process occurs or a flash program event is requested.

Data 1 is ONLY updated by the reset cause in the case of a back-up register corruption. This is done to not “lose” data following an NTC event.

// SetMcuDiagcIdnData(Microcontroller Diagnostic Identification Data)

SetMcuDiagcIdnData (McuDiagcData0, McuDiagcData1)

// Update data if different from PwrOnRst or FlsProgmCmpl – OR if flash prog is requested

If ((BRAMDAT0 = McuDiagc1.MCUDIAGC_FLSPROGMREQ) OR

(BRAMDAT0 = McuDiagc1.MCUDIAGC_PWRONRST) OR

(BRAMDAT0 = McuDiagc1.MCUDIAGC_DBGRST) OR

(BRAMDAT0 = McuDiagc1.MCUDIAGC_FLSPROGMCMPL) OR (BRAMDAT0 = McuDiagc1.MCUDIAGC_HARDRST) OR (BRAMDAT0 = McuDiagc1.MCUDIAGC_SOFTRST)) Then

BRAMDAT0 = McuDiagcData0

BRAMDAT1 = McuDiagcData1

End If

Done

‘ChkForStrtUpTest’ function is used to check if a startup test has to be performed or not.

The point of this test is to avoid getting into continuous reset loops due to some faults getting set. We perform start up tests on only those kinds of resets which are not a result of faults being set. When a reset causing fault occurs, we’d only want to reset the controller and move to a safe state. Therefore, we only run start up tests only when we come out of a Power On Reset, or when the Flash Programming is Complete or when we received reset commands from Serial Communication such as Soft Reset and Hard Reset.

ChkForStrtUpTest (P2VAR ExecStrtUpTest)

{

If ((BRAMDAT0 = McuDiagc1.MCUDIAGC_PWRONRST) OR 

(BRAMDAT0 = McuDiagc1.MCUDIAGC_FLSPROGMCMPL) OR 

(BRAMDAT0 = McuDiagc1.MCUDIAGC_HARDRST) OR 

(BRAMDAT0 = McuDiagc1.MCUDIAGC_SOFTRST))

{

*ExecStrtUpTest = TRUE;

}

Else

{

*ExecStrtUpTest = FALSE;

}

}

Revision Record & Change Approval

RevDateChange Control #DrwChange Description
1.0.010/20/2015EA4#1831MKInitial Release
1.1.011/19/2015EA4#2536SKRemoved CVMREN Initialization. Refer Anomaly EA4#2522
1.2.001/08/16EA4#3186LWWReplaced Os Protection and Error Hook
2.0.001/21/2016EA4#3413SKAdded Clock Monitor FE, Soft Reset, Hard Reset conditions, P Bus Data Parity Check
2.1.002/08/2016EA4#3729SKUpdated SAN section for DTS 2Bit ECC, ECM Master/Checker Compare, Added Start Up Test for P Bus and PBG Start up test, Added function ChkForStrtUpTest 
2.1.102/12/2016EA4#3847SKCorrected parameter bit for NTC of PBGSTRTUPTST, Update Clock Monitors FENMI ISR for typos.
2.2.003/17/2016EA4#4519SKRemoved DTS Double RAM FENMI Section and added the DTS Double RAM ECC as a part of SYSERR
3.0.003/29/2016EA4#4863GM

Added new MCUDIAGC_INVLDRAMAREA, MCUDIAGC_FACIRSTTRFERR, MCUDIAGC_SNGCHIPINACTV, MCUDIAGC_CODFLSECCSNGBITERR, MCUDIAGC_DBGRST

Added new NTC 013.2, 022.6 and 02F.0

Removed SPI double bit ECC faults (added to CM103A)

NTC 021.0 name changed from BIST Code 2-bit ECC Failure to 021.0 BIST Code ECC Failure

3.0.104/07/2016EA4#5184GM

Add NTC 13.2 to NTC list in section 4.29.1

Add NTC 02F.0 to NTC list in section 4.29.1

Change NTC 025.0 description to MPU Violation (this convers MDP and MIP Exception) from Data Protection Violation (MDP Exception) in section 4.29.1

Change NTC 025.1 description to Privilege Instruction Execution from Execution Protection Violation (MIP Exception) in section 4.29.1

2 - CM101A_ExcpnHndlr_FDD_Review_Checklis

Nexteer_Template_V1.0

Overview

Peer Review Instructions
Technical Review Checklist
Template Change Log


Sheet 1: Peer Review Instructions

Instructions for Functional Design Package Peer Review




PRE-MEETING


Function OwnerConfirm that requirements are reviewed and approved PRIOR to the FDP peer review

Function OwnerStart with latest version of the template for any "first reviews" - Continue to use existing temmplate for re-reviews

Function OwnerProvide the functional design package (changed documents) to the invited attendees 1-2 working days in advance of review

Function OwnerNotify the assigned peer reviewer and make sure they are prepared to do their function in the meeting

Function OwnerIdentify necessary attendance and invite to meeting

Function OwnerComplete the "Author" column information for sections 1 through 3 prior to the review

Function OwnerComplete the attendance invitation list in section 5

Function OwnerFor Re-reviews only: Complete the column "remarks by author" to identify actions taken to address items found in earlier reviews.



DURING MEETING


Function OwnerPresent document changes to the review team

Peer ReviewerCapture attendance of the review

Peer ReviewerCapture actions and issues in section 4. Identify issue summary, Document type, Reference (Requirement ID, section number, etc), Defect Type and indicate status as "OPEN"



POST MEETING


Function OwnerFollow up on all "open" items. Update "Summary of Resolution" to indicate what was done or decided.

Function OwnerSchedule follow up review OR review open items with peer reviewer and obtain agreement to close

Peer ReviewerClose change request in system and confirm all associated tasks are complete. Upload peer review checklist (this document) with any FDP updates

Sheet 2: Technical Review Checklist

Technical Review Checklist - Template Version 01.00.09







Product NameElectric Power SteeringElectrical Arch.4Review ScopeDefect TypeNumbers




YesClosedFR
Function NameCM101A Exception HandlingVersion
EA4#5184Requirement0




NoRejectedFDD
AuthorGerald McCann

Interface0




NAOpenModel


EffortDesign0






FMEA


Review Effort(Hrs.)0.50Standards0






*.m File


Corr+Verf effort(Hrs.)0.00Documentation0






Cal Process


Total Effort (Hrs.)0.50Others0













Total0







Checklist No.Description of CheckAuthor: This column is for Self review. Author shall fill Yes/No/NA against each point in checklist. AuthorAuthor: This column is for reviewer. Reviewer shall fill Yes/No/NA against each point in checklist. ReviewerAuthor: Detailed Description of the finding shall be provided by the reviewer. Description of finding by reviewerAuthor: Defect type to be selected. Defect TypeAuthor: What action is taken to fix the comment & other remarks need to be filled by author. Remarks By AuthorAuthor: Data in this column shall be filled by reviewer after checking whether the rework is completed. Status







1Section 1: TECHNICAL CHECK













1.1Confirm that all signal inputs into the FDP (Functional Design Package) are contained within and exactly named as the "Available_Nexteer_Signals.m" states.YesYes











1.2Confirm any removed signal inputs from the design have been removed from the "Available_Nexteer_Signals.m" file.NANA











1.3Confirm all signals and parameters (outputs, calibrations, constants, non-volatile memory) used in the *.m file and the design conform to the AutoSAR naming convention documentation.YesYes











1.4Confirm *.m file has been provided to the "Available_Signal_Names" Author.YesYes











1.5Confirm Electrical Systems interface map is updated to reflect the FDP (signal IO)NANA











1.6Confirm that Static Register evaluation has been completed and updated for any register data that is written to.NoNo











1.7Have calibration default values been reviewed for correctness?NANA











2Section 2: Safety CHECKAuthor: This column is for Self review. Author shall fill Yes/No/NA against each point in checklist. AuthorAuthor: This column is for reviewer. Reviewer shall fill Yes/No/NA against each point in checklist. ReviewerAuthor: Detailed Description of the finding shall be provided by the reviewer. Description of finding by reviewerAuthor: Defect type to be selected. Defect TypeAuthor: What action is taken to fix the comment & other remarks need to be filled by author. Remarks By AuthorAuthor: Data in this column shall be filled by reviewer after checking whether the rework is completed. Status







2.1Confirm that the functional DFMEA is up to date based on the design in the current package.NANA











2.2Confirm that Safety requirements (ASIL A - D) are referenced in the design documents.NANA











3Section 3: Lessons LearnedAuthor: This column is for Self review. Author shall fill Yes/No/NA against each point in checklist. AuthorAuthor: This column is for reviewer. Reviewer shall fill Yes/No/NA against each point in checklist. ReviewerAuthor: Detailed Description of the finding shall be provided by the reviewer. Description of finding by reviewerAuthor: Defect type to be selected. Defect TypeAuthor: What action is taken to fix the comment & other remarks need to be filled by author. Remarks By AuthorAuthor: Data in this column shall be filled by reviewer after checking whether the rework is completed. Status







3.01Have functions depending upon system state been reviewed for need to be executed at the 2ms rate to avoid system lag issues?YesYes











3.02Have all diagnostics (NTCs) been confirmed to show logic to invoke a diagnostic "PASS" for control of the status byte at the customer level.YesYes











3.03Has the requirements traceability steps used the RMI steps as defined in the FDD authoring spec to generate the traceability report?NANA











3.04Has the requirements traceability report been verified to only contain ONLY requirements from the FR.NANA











3.05Confirm that all PIM that does NOT have an initialization value of zero is initialized in an INIT function.NANA











3.06Confirm if NVM is used, the NVM is defined in structuresNANA











3.07If the function uses NVM, confirm that the m file uses the SetBlockStatus to indicate a write at powerdownNANA











3.08Confirm NTCs are not set within an IRQ (not related to the typical periodic OS)YesYes











3.09Confirm NTCs are not set or read in a periodic rate faster than 2 ms (ex. Motor Control Loop)YesYes











3.10Constants check: Do all constants have the correct scope (local, global) and are they defined in the correct location (this FDD, ES/SF/AR999)?YesYes











3.11Confirm all calibrations are required (ie they cannot be constants)YesYes











4Section 4: Issues / Actions IdentifiedDocumentReferenceSummary of resolutionAuthor: Defect type to be selected. Defect TypeAuthor: What action is taken to fix the comment & other remarks need to be filled by author. Remarks By AuthorAuthor: Data in this column shall be filled by reviewer after checking whether the rework is completed. Status







4.1














4.2














4.3














4.4














4.5














4.6














4.7














4.8














4.9














4.10














4.11














4.12














4.13














4.14














4.15














4.16














4.17














4.18














4.19














4.20














4.21














4.22














4.23














4.24














4.25














5Section 5: APPROVALS













RoleFirst ReviewDateAttendanceApproval?










Function Owner*Gerald McCann4/7/2016YesYes










Peer Reviewer*Samanth KumaraswamyYes










EPDT Engineer












ES Engineer












Software LeadAvinash JamesYes










Hardware Lead












Test Lead












Safety Lead












RoleSecond Review (if required)DateAttendanceApproval?










Function Owner*<Owner Name>













Peer Reviewer*<Name>











EPDT Engineer<Name - if invited>











ES Engineer<Name - if invited>











Software Lead<Name - if invited>











Hardware Lead<Name - if invited>











Test Lead<Name - if invited>











Safety Lead<Name - if invited>











RoleThird Review (if required)DateAttendanceApproval?










Function Owner*<Owner Name>













Peer Reviewer*<Name>











EPDT Engineer<Name - if invited>











ES Engineer<Name - if invited>











Software Lead<Name - if invited>











Hardware Lead<Name - if invited>











Test Lead<Name - if invited>











Safety Lead<Name - if invited>











RoleFourth Review (if required)DateAttendanceApproval?










Function Owner*<Owner Name>













Peer Reviewer*<Name>











EPDT Engineer<Name - if invited>











ES Engineer<Name - if invited>











Software Lead<Name - if invited>











Hardware Lead<Name - if invited>











Test Lead<Name - if invited>











Safety Lead<Name - if invited>











RoleAdd more if necessaryDateAttendanceApproval?










































P.S.:Yes indicates adherence














No indicates non-adherence, reviewer shall provide suitable comments at the end of this document for each point.














NA indicates not applicable














Sheet 3: Template Change Log

RevChangeAuthor
01.00.05Added lesson learned #3.5MDK
01.00.06Added lesson learned #3.6, 3.7 - Structure and writing of NVM in mfiles and models.MDK
01.00.07Clarified 3.6 and 3.7
Added lessons learned for NTCs not being set in IRQs or periodics faster than 2ms/
MDK
01.00.08Added section 1.6 to look for critical static register analysisMDK
01.00.09Added two checks - default cals and are all cals really required to be a calibrationMDK