EA4 NTC 0x040 TmplMonrRunTimeFlt

Slide 1

NTC Temporal Monitor Run Fault
Overview - NTC 0x041

FDD: ES005A

Description:

This diagnostic is responsible for detecting Temporal Monitor Run Time faults.

Diagnostic Overview:

The temporal Monitor Function monitors the POE output of the Temporal Monitor IC (A4412) and if the POE is low, A SPI message is sent to the IC to check the type of Fault (WatchDog Fault or Non-WatchDog Fault). This Fault is captured by NTC 0x041.

Typical Fault Response:  

    • F3  Failure
       

Probable Sources (Most to Least Probable):

      • Temporal Monitor IC(A4412) fault. 

      • WD_Monitor pulse fault. 

      • POE fault. 

Initialization

 

Periodic

X

Event

 

Bit

Cause

0

WatchDog type Failure

1

Non-WatchDog type Failure.

2

Unused

3

Unused

4

Unused

5

Unused

6

Unused

7

Unused

Rev

Revision

 

Initial Release

  
  
  
  
  
  
  
  
  

Revision Log