EA4-x NTC 0x0A4(0-2) Absolute Temperature Thermal Limit
NTC Overview
NTC 0x0A4.(0-2) Absolute Temperature Thermal Limit
Description:
- •This diagnostic logs a fault when either the controller temperature or copper temperature estimate exceed calibrated values. 
Diagnostic Overview:
- •The system components are designed to operated below specific temperature thresholds. If these threshold values are exceeded, a limit is applied to the system via limit tables to protect the components, and a diagnostic flag is set. 
- •This is a recoverable fault that clears once the controller temperature or copper temperature fall below the calibrated thresholds. 
 
Typical Fault Response:
- •Response for this diagnostic is F3. 
- •This fault is recoverable once the temperature values fall below the threshold within an ignition cycle. 
 
Probable Sources 
(Most to Least Probable):
- •Excessive system usage 
- •System is exposed to high ambient temperature. 
| Initialization | |
| Periodic | X | 
| Event | 
| Bit | Cause | 
| 0 | Limiting due to Controller Temperature | 
| 1 | Limiting due to Copper Temperature | 
| 2 | Limiting due to Both Temperatures | 
| Date | Revision | Initials | 
| 08FE16 | Initial Release | JK | 
| 10Au16 | Update the bits table with 3 bits used in the NTC | PP | 
| Description of Unusual Event setting NTC | Root Cause / Explanation | 
| Date | FDD & Rev | Modifications to Diagnostic Function | 
Algorithm Changes / Lessons Learned / Revision Log